From version < 4.2 >
edited by Xiaoling
on 2022/05/11 14:30
To version < 4.18 >
edited by Xiaoling
on 2022/05/11 15:35
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -104,15 +104,23 @@
104 104  
105 105  [[image:https://wiki.dragino.com/images/thumb/3/3a/CN470_FRE_BAND-1.png/600px-CN470_FRE_BAND-1.png||height="205" width="600"]]
106 106  
107 +(((
107 107  CN470 Channels
109 +)))
108 108  
111 +(((
109 109  If we look at the [[TTN network server frequency plan>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]], we can see the US915 frequency band use the channel 8~~15.So the End Node must work at the same frequency in US915 8~~15 channels for TTN server.
113 +)))
110 110  
111 111  [[image:https://wiki.dragino.com/images/thumb/9/9a/US915_FRE_BAND-2.png/600px-US915_FRE_BAND-2.png||height="288" width="600"]]
112 112  
117 +(((
113 113  TTN FREQUENCY PLAN
119 +)))
114 114  
121 +(((
115 115  In dragino end node, user can use AT+CHE command to set what frequencies set the end node will use. The default settings for Dragino end node are preconfigure for TTN server, so use 8~~15 channels, which is **AT+CHE=2**. (AT+CHE=1 for first 8 channels, AT+CHE=2 for second 8 channels.. etc, and AT+CHE=0 for all 72 channels. )
123 +)))
116 116  
117 117  
118 118  = 3. Why i see data lost/unperiocially uplink data? Even the signal strength is good =
... ... @@ -123,18 +123,40 @@
123 123  * **Gateway** ~-~-> Use Sub-band2 (Channel 8,9,10,11,12,13,14,15) for Dragino Gateway. this is the default settings for dragino sensors.
124 124  * **LoRaWAN server** ~-~-> ChirpStack default installation and use Sub-band1, **enabled_uplink_channels=[0, 1, 2, 3, 4, 5, 6, 7]** in the file chirpstack-network-server.toml.
125 125  
134 +(((
126 126  When Sensor power on, it will use sub-band2 to join the network, the frequency matches the settings in gateway so all Join Request will be passed to the server for Join. Server will ask the sensor to change to Sub-band1 in the Join Accept downlink message. Sensor will change to sub-band1 for data upload. This cause the sensor and gateway have different frequencies so user see lost of most data or even no data.
136 +)))
127 127  
138 +(((
139 +
140 +)))
141 +
142 +(((
128 128  Use Subband2 as a default subband cause the sensor to have problem to work with the LoRaWAN server which use other subband, and use need to access to the end node to change the subband by console. that is not user frendily,. So since Dragino LoRaWAN Stack version DLS-005(release on end of 2020), we have changed the device to use All Subbands for OTAA join, for example, device will use the first frequency in Sub-Band1 as firt OTAA join packet, then use the first frequency in Sub-Band 2 , then first frequency in sub-band 3, and so on. LoRaWAN server will normally provide the required subband in the OTAA accept process, so end node will know what subband it use after join. If LoRaWAN server doesn't provide subband info in OTAA join, end node will use the subband which join success as the working subband. So the new method cause a longer OTAA Join time but will be compatible with all LoRaWAN server. And new method won't affect the normal uplink after Join Success.
144 +)))
129 129  
130 130  
131 131  = 4. Transmision on ABP Mode =
132 132  
149 +(((
133 133  In ABP mode, there is a Frame Counter Checks. With this check enabled, the server will only accept the frame with a higher counter. If you reboot the device in ABP mode, the device will start from count 0, so you won't be able to see the frame update in server.
151 +)))
134 134  
153 +(((
154 +
155 +)))
156 +
157 +(((
135 135  So in ABP mode, first check if the packet already arrive your gateway, if the packet arrive gatewat but didn't arrive server. Please check if this is the issue.
159 +)))
136 136  
161 +(((
162 +
163 +)))
164 +
165 +(((
137 137  To solve this, disable the Frame Counter Check will solve this issue , or reset the frame counter in the device page.
167 +)))
138 138  
139 139  [[~[~[image:https://wiki.dragino.com/images/thumb/1/19/ABP_Issue-1.jpg/600px-ABP_Issue-1.jpg~|~|height="340" width="600"~]~]>>url:https://wiki.dragino.com/index.php/File:ABP_Issue-1.jpg]]
140 140  
... ... @@ -147,7 +147,9 @@
147 147  
148 148  LoRaWAN End node will open two receive windows to receive the downstream data. If the downstream packets arrive the end node at these receive windows, the end node will be able to get this packet and process it.
149 149  
180 +(((
150 150  Depends on Class A or Class C, the receive windows will be a little difference,
182 +)))
151 151  
152 152  [[image:https://wiki.dragino.com/images/thumb/1/1a/Downstream_LoRaWAN-1.png/600px-Downstream_LoRaWAN-1.png||height="590" width="600"]]
153 153  
... ... @@ -163,81 +163,104 @@
163 163  
164 164  == 5.2 See Debug Info ==
165 165  
198 +(((
166 166  **For LoRaWAN Server**
200 +)))
167 167  
202 +(((
168 168  We can check if there is downlink message for this end node, use TTN for example:
204 +)))
169 169  
206 +(((
170 170  Configure a downstream to the end device
208 +)))
171 171  
172 172  [[image:https://wiki.dragino.com/images/thumb/8/82/Downstream_debug_1.png/600px-Downstream_debug_1.png||height="217" width="600"]]
173 173  
212 +(((
174 174  Set a downstream in TTN and see it is sent
214 +)))
175 175  
176 176  
217 +(((
177 177  This downstream info will then pass to the gateway downstream list. and include the DR which is used (SF9BW125) in EU868 is DR3
219 +)))
178 178  
179 179  [[image:https://wiki.dragino.com/images/thumb/d/dc/Downstream_debug_2.png/600px-Downstream_debug_2.png||height="245" width="600"]]
180 180  
223 +(((
181 181  Gateway Traffic can see this downstream info
225 +)))
182 182  
183 183  
228 +(((
184 184  **For LoRaWAN Gateway**
230 +)))
185 185  
232 +(((
186 186  When the downstream packet appear on the traffic of Gateway page. The LoRaWAN gateway can get it from LoRaWAN server and transmit it. In Dragion Gateway, this can be checked by runinng "logread -f" in the SSH console. and see below:
234 +)))
187 187  
188 188  [[image:https://wiki.dragino.com/images/thumb/2/21/Downstream_debug_3.png/600px-Downstream_debug_3.png||height="195" width="600"]]
189 189  
238 +(((
190 190  Gateway Sent out this packet
240 +)))
191 191  
192 192  
243 +(((
193 193  **For End Node**
245 +)))
194 194  
247 +(((
195 195  we can use AT Command (AT+CFG) to check the RX1 configure and RX2 configure. as below:
249 +)))
196 196  
197 -(% class="box infomessage" %)
198 198  (((
199 -AT+RX2FQ=869525000 ~-~--> The RX2 Window frequency
252 +
200 200  )))
201 201  
255 +(((
202 202  (% class="box infomessage" %)
203 203  (((
204 -AT+RX2DR=3 ~-~--> The RX2 DataRate
258 +AT+RX2FQ=869525000     ~-~--> The RX2 Window frequency
259 +AT+RX2DR=3      ~-~--> The RX2 DataRate
260 +AT+RX1DL=1000   ~-~--> Receive Delay 1
261 +AT+RX2DL=2000   ~-~--> Receive Delay 2
205 205  )))
263 +)))
206 206  
207 -(% class="box infomessage" %)
208 208  (((
209 -AT+RX1DL=1000 ~-~--> Receive Delay 1
266 +**when the device running, we can see below info:**
210 210  )))
211 211  
212 -(% class="box infomessage" %)
269 +{{{ [12502]***** UpLinkCounter= 0 *****
270 + [12503]TX on freq 868500000 Hz at DR 0
271 + [13992]txDone
272 + [15022]RX on freq 868500000 Hz at DR 0 --> RX1 window open at frequency: 868500000, DR0, after 15022-13992= 1030ms of txdone
273 + [15222]rxTimeOut --> no packet arrive in RX1 window. (duration: 200ms)
274 + [15987]RX on freq 869525000 Hz at DR 3 --> RX2 window open at frequency: 869525000, DR3, after 15987-13992= 1995ms of txdone
275 + [16027]rxTimeOut --> no packet arrive in RX2 window. (duration: 40 ms)}}}
276 +
213 213  (((
214 -AT+RX2DL=2000 ~-~--> Receive Delay 2
278 +
215 215  )))
216 216  
217 -when the device running, we can see below info:
281 +(((
282 +**Another message:**
283 +)))
218 218  
219 -{{{[12502]***** UpLinkCounter= 0 *****
220 -[12503]TX on freq 868500000 Hz at DR 0
221 -[13992]txDone
222 -[15022]RX on freq 868500000 Hz at DR 0 --> RX1 window open at frequency: 868500000, DR0, after 15022-13992= 1030ms of txdone
223 -[15222]rxTimeOut --> no packet arrive in RX1 window. (duration: 200ms)
224 -[15987]RX on freq 869525000 Hz at DR 3 --> RX2 window open at frequency: 869525000, DR3, after 15987-13992= 1995ms of txdone
225 -[16027]rxTimeOut --> no packet arrive in RX2 window. (duration: 40 ms)
226 -}}}
285 +{{{ [12502]***** UpLinkCounter= 0 *****
286 + [12503]TX on freq 868100000 Hz at DR 0
287 + [13992]txDone
288 + [15022]RX on freq 868100000 Hz at DR 0
289 + [15222]rxTimeOut
290 + [15987]RX on freq 869525000 Hz at DR 3
291 + [16185]rxDone --> We have got the downstream packet.
292 + Rssi= -64
293 + Receive data
294 + 1:0012345678}}}
227 227  
228 -{{{Another message:
229 -[12502]***** UpLinkCounter= 0 *****
230 -[12503]TX on freq 868100000 Hz at DR 0
231 -[13992]txDone
232 -[15022]RX on freq 868100000 Hz at DR 0
233 -[15222]rxTimeOut
234 -[15987]RX on freq 869525000 Hz at DR 3
235 -[16185]rxDone --> We have got the downstream packet.
236 -Rssi= -64
237 -Receive data
238 -1:0012345678
239 -}}}
240 -
241 241  == 5.3 If problem doesn’t solve ==
242 242  
243 243  **If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the sceenshots for each step to check. They include:**
... ... @@ -249,14 +249,27 @@
249 249  
250 250  = 6. Downlink Issue ~-~- Packet REJECTED, unsupported frequency =
251 251  
307 +(((
252 252  In LoRaWAN, the gatewat will use the frequency specify by the server to transmit a packet as downlink purpose. Each Frequency band has different downlink frequency. and the gateway has a frequency range limited to transmit downlink.
309 +)))
253 253  
311 +(((
312 +
313 +)))
314 +
315 +(((
254 254  So if the LoRaWAN server is an AS923 server which ask the gateway to transmit at 923.2Mhz frequency, but the gateway is IN868 frequency band (support 865~~867Mhz to transmit). In the gateway log it will show something like below:
317 +)))
255 255  
256 -{{{Sat Nov 21 08:04:17 2020 daemon.info lora_pkt_fwd[1680]: ERROR~ Packet REJECTED, unsupported frequency - 923200000 (min:865000000,max:867000000)
257 -}}}
319 +{{{Sat Nov 21 08:04:17 2020 daemon.info lora_pkt_fwd[1680]: ERROR~ Packet REJECTED, unsupported frequency - 923200000 (min:865000000,max:867000000)}}}
258 258  
321 +(((
322 +
323 +)))
324 +
325 +(((
259 259  In this case, please double check the gateway frequency and the server frequency band.
327 +)))
260 260  
261 261  
262 262  = 7. Decrypt a LoRaWAN Packet =
... ... @@ -304,7 +304,9 @@
304 304  
305 305  [[image:https://wiki.dragino.com/images/7/77/Decrypt_a_LoRaWAN_Packet4.png||alt="Decrypt a LoRaWAN Packet4.png" height="390" width="558"]]
306 306  
307 -The FRMPayload is the device payload.
375 +(((
376 + The FRMPayload is the device payload.
377 +)))
308 308  
309 309  
310 310  = 8. Why i see uplink 0x00 periodcally on the LHT65 v1.8 firmware =
... ... @@ -313,32 +313,56 @@
313 313  
314 314  = 9. Why do I see a "MIC Mismatch" error message from the server? =
315 315  
386 +(((
316 316  1)If the user receives a "MIC Mismatch" message after registering the node on the server.
388 +)))
317 317  
390 +(((
318 318  It is likely that the user filled in the wrong APPKEY when registering the node. Many users fill in "APPSKEY".
392 +)))
319 319  
320 -* Please note the distinction between "APPKEY" and "APPSKEY".
394 +* (((
395 +Please note the distinction between "APPKEY" and "APPSKEY".
396 +)))
321 321  
398 +(((
322 322  2)If the node works on the server for a period of time, the device stops working and receives a "MIC Mismatch" message.
400 +)))
323 323  
402 +(((
324 324  The user needs a USB-TTL adapter to connect the serial port to modify the node APPKEY.
404 +)))
325 325  
326 -* If a node is registered with multiple servers, it may also cause the "mic mismatch" error.
406 +* (((
407 +If a node is registered with multiple servers, it may also cause the "mic mismatch" error.
408 +)))
327 327  
328 328  = 10. Why i got the payload only with "0x00" or "AA~=~="? =
329 329  
330 330  * If you are using US915, AU915 and AS923 frequencies.This is normal phenomenon.
331 331  
332 -When using the frequency mentioned above, the server sometimes adjusts the rate of the node, because the node defaults to the adaptive rate.
414 +(((
415 + When using the frequency mentioned above, the server sometimes adjusts the rate of the node, because the node defaults to the adaptive rate.
416 +)))
333 333  
334 -When the server adjusts your node rate to 0, the maximum payload length is 11 bytes. The server sometimes sends an ADR packet to the node,
418 +(((
419 + When the server adjusts your node rate to 0, the maximum payload length is 11 bytes. The server sometimes sends an ADR packet to the node,
420 +)))
335 335  
336 -and the node will reply to the server after receiving the ADR packet, but the number of payload bytes exceeds the limit,
422 +(((
423 + and the node will reply to the server after receiving the ADR packet, but the number of payload bytes exceeds the limit,so it will send a normal
424 +)))
337 337  
338 -so it will send a normal uplink packet, and an additional 00 data packet.
426 +(((
427 + uplink packet, and an additional 00 data packet.
428 +)))
339 339  
340 -* Solution: Use the decoder to filter out this 00 packet.
341 -* Some node decoders may not have filtering function, or you need decoders of other servers and formats. Please send an email to david.huang@dragino.cc
430 +* (((
431 +Solution: Use the decoder to filter out this 00 packet.
432 +)))
433 +* (((
434 +Some node decoders may not have filtering function, or you need decoders of other servers and formats. Please send an email to david.huang@dragino.cc
435 +)))
342 342  
343 343  (% class="wikigeneratedid" id="H" %)
344 344  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved