From version < 32.3 >
edited by Xiaoling
on 2022/07/13 14:59
To version < 32.7 >
edited by Xiaoling
on 2022/07/13 15:10
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -205,7 +205,6 @@
205 205  * This packet must match the frequency of the RX1 or RX2 window.
206 206  * This packet must match the DataRate of RX1(RX1DR) or RX2 (RX2DR). (% style="color:red" %)**This is the common fail point, because different lorawan server might use different RX2DR and they don't info End Node via ADR message so cause the mismatch. If this happen, user need to change the RX2DR to the right value in end node. In OTAA, LoRaWAN Server will send the RX2DR setting in Join Accept message so the end node will auto adjust. but ABP uplink doesn't support this auto change.**
207 207  
208 -
209 209  == 5.2 See Debug Info ==
210 210  
211 211  
... ... @@ -263,20 +263,15 @@
263 263  )))
264 264  
265 265  (((
265 +(% style="color:#037691" %)**AT+RX2FQ=869525000**  (%%) **~-~-->**  The RX2 Window frequency
266 +(% style="color:#037691" %)**AT+RX2DR=3**          (%%) **~-~-->**  The RX2 DataRate
267 +(% style="color:#037691" %)**AT+RX1DL=1000**       (%%) ** ~-~-->**  Receive Delay 1
268 +(% style="color:#037691" %)**AT+RX2DL=2000**       (%%) **~-~--> ** Receive Delay 2
269 +
266 266  
267 267  )))
268 268  
269 269  (((
270 -(% class="box infomessage" %)
271 -(((
272 -AT+RX2FQ=869525000     ~-~--> The RX2 Window frequency
273 -AT+RX2DR=3      ~-~--> The RX2 DataRate
274 -AT+RX1DL=1000   ~-~--> Receive Delay 1
275 -AT+RX2DL=2000   ~-~--> Receive Delay 2
276 -)))
277 -)))
278 -
279 -(((
280 280  (% style="color:blue" %)**when the device running, we can see below info:**
281 281  )))
282 282  
... ... @@ -308,8 +308,9 @@
308 308   1:0012345678}}}
309 309  
310 310  
311 -== 5.3 If problem doesnt solve ==
305 +== 5.3 If problem doesn't solve ==
312 312  
307 +
313 313  (% style="color:red" %)**If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the sceenshots for each step to check. They include:**
314 314  
315 315  * End node console to show the transmit freuqency and DR.
... ... @@ -317,8 +317,11 @@
317 317  * Gateway traffic (from server UI) to shows the data exchange between gateway and server.
318 318  * End Node traffic (from server UI) to shows end node activity in server.
319 319  
315 +
316 +
320 320  = 6. Downlink Issue ~-~- Packet REJECTED, unsupported frequency =
321 321  
319 +
322 322  (((
323 323  In LoRaWAN, the gatewat will use the frequency specify by the server to transmit a packet as downlink purpose. Each Frequency band has different downlink frequency. and the gateway has a frequency range limited to transmit downlink.
324 324  )))
... ... @@ -344,19 +344,17 @@
344 344  
345 345  = 7. Decrypt a LoRaWAN Packet =
346 346  
347 -~1. LHT65 End device configure:
348 348  
349 -(% class="box infomessage" %)
350 -(((
351 -**Change to ABP Mode: AT+NJM=0**
352 -**Change to fix frequency: AT+CHS=904900000**
353 -**Change to fix DR: AT+DR=0**
354 -)))
346 +(% style="color:blue" %)**1. LHT65 End device configure:**
355 355  
348 +**Change to ABP Mode:  AT+NJM=0**
349 +**Change to fix frequency:  AT+CHS=904900000**
350 +**Change to fix DR:  AT+DR=0**
351 +
356 356  [[image:image-20220526165525-16.png]]
357 357  
358 358  
359 -2. In LG02 , configure to receive above message
355 +(% style="color:blue" %)**2. In LG02 , configure to receive above message**
360 360  
361 361  [[image:image-20220526165612-17.png]]
362 362  
... ... @@ -366,7 +366,7 @@
366 366  [[image:image-20220526171112-21.png]]
367 367  
368 368  
369 -3. Decode the info in web
365 +(% style="color:blue" %)**3. Decode the info in web**
370 370  
371 371  [[https:~~/~~/lorawan-packet-decoder-0ta6puiniaut.runkit.sh>>url:https://lorawan-packet-decoder-0ta6puiniaut.runkit.sh/]]
372 372  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0