Changes for page LoRaWAN Communication Debug
Last modified by Edwin Chen on 2025/01/29 20:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -205,7 +205,6 @@ 205 205 * This packet must match the frequency of the RX1 or RX2 window. 206 206 * This packet must match the DataRate of RX1(RX1DR) or RX2 (RX2DR). (% style="color:red" %)**This is the common fail point, because different lorawan server might use different RX2DR and they don't info End Node via ADR message so cause the mismatch. If this happen, user need to change the RX2DR to the right value in end node. In OTAA, LoRaWAN Server will send the RX2DR setting in Join Accept message so the end node will auto adjust. but ABP uplink doesn't support this auto change.** 207 207 208 - 209 209 == 5.2 See Debug Info == 210 210 211 211 ... ... @@ -263,20 +263,15 @@ 263 263 ))) 264 264 265 265 ((( 265 +(% style="color:#037691" %)**AT+RX2FQ=869525000** (%%) **~-~-->** The RX2 Window frequency 266 +(% style="color:#037691" %)**AT+RX2DR=3** (%%) **~-~-->** The RX2 DataRate 267 +(% style="color:#037691" %)**AT+RX1DL=1000** (%%) ** ~-~-->** Receive Delay 1 268 +(% style="color:#037691" %)**AT+RX2DL=2000** (%%) **~-~--> ** Receive Delay 2 269 + 266 266 267 267 ))) 268 268 269 269 ((( 270 -(% class="box infomessage" %) 271 -((( 272 -AT+RX2FQ=869525000 ~-~--> The RX2 Window frequency 273 -AT+RX2DR=3 ~-~--> The RX2 DataRate 274 -AT+RX1DL=1000 ~-~--> Receive Delay 1 275 -AT+RX2DL=2000 ~-~--> Receive Delay 2 276 -))) 277 -))) 278 - 279 -((( 280 280 (% style="color:blue" %)**when the device running, we can see below info:** 281 281 ))) 282 282