... ... @@ -207,9 +207,6 @@
207 207  * This packet must match the frequency of the RX1 or RX2 window.
208 208  * This packet must match the DataRate of RX1(RX1DR) or RX2 (RX2DR). (% style="color:red" %)**This is the common fail point, because different lorawan server might use different RX2DR and they don't info End Node via ADR message so cause the mismatch. If this happen, user need to change the RX2DR to the right value in end node. In OTAA, LoRaWAN Server will send the RX2DR setting in Join Accept message so the end node will auto adjust. but ABP uplink doesn't support this auto change.**
209 209  
210 -
211 -
212 -
213 213  == 5.2 See Debug Info ==
214 214  