Changes for page LoRaWAN Communication Debug
Last modified by Edwin Chen on 2025/01/29 20:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,9 +1,12 @@ 1 1 **~ Contents:** 2 2 3 +((( 4 + 5 +))) 6 + 3 3 {{toc/}} 4 4 5 5 6 - 7 7 = 1. OTAA Join Process Debug = 8 8 9 9 These pages are useful to check what is wrong on the Join process. Below shows the four steps that we can check the Join Process. ... ... @@ -194,8 +194,6 @@ 194 194 * This packet must match the frequency of the RX1 or RX2 window. 195 195 * This packet must match the DataRate of RX1(RX1DR) or RX2 (RX2DR). **This is the common fail point, because different lorawan server might use different RX2DR and they don't info End Node via ADR message so cause the mismatch. If this happen, user need to change the RX2DR to the right value in end node. In OTAA, LoRaWAN Server will send the RX2DR setting in Join Accept message so the end node will auto adjust. but ABP uplink doesn't support this auto change.** 196 196 197 - 198 - 199 199 == 5.2 See Debug Info == 200 200 201 201 ((( ... ... @@ -306,8 +306,6 @@ 306 306 * Gateway traffic (from server UI) to shows the data exchange between gateway and server. 307 307 * End Node traffic (from server UI) to shows end node activity in server. 308 308 309 - 310 - 311 311 = 6. Downlink Issue ~-~- Packet REJECTED, unsupported frequency = 312 312 313 313 ((( ... ... @@ -437,66 +437,38 @@ 437 437 * ((( 438 438 Some node decoders may not have filtering function, or you need decoders of other servers and formats. Please send an email to [[david.huang@dragino.cc>>mailto:david.huang@dragino.cc]] 439 439 439 + 440 440 441 441 ))) 442 442 443 443 = 11. Why my Dev EUI and APP EUI is 0x000000000000, how to solve? = 444 444 445 -((( 446 446 It is possible the keys is erased during upgrading of firmware. and the console output shows below after AT+CFG 447 -))) 448 448 449 -((( 450 450 AT+APPKEY=00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 451 -))) 452 452 453 -((( 454 454 AT+NWKSKEY=00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 455 -))) 456 456 457 -((( 458 458 AT+APPSKEY=00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 459 -))) 460 460 461 -((( 462 462 AT+APPEUI=00 00 00 00 00 00 00 00 463 -))) 464 464 465 -((( 466 - 467 -))) 468 468 469 -((( 470 470 You can get the keys from the box sticker or send mail to Dragino Support to check keys with the provided SN number. 471 -))) 472 472 473 -((( 474 474 You can rewrites the keys by running commands in AT Console 475 -))) 476 476 477 -((( 478 -**For example:** 479 -))) 460 +For example: 480 480 481 -((( 482 482 AT+APPKEY=85 41 47 20 45 58 28 14 16 82 A0 F0 80 0D DD EE 483 -))) 484 484 485 -((( 486 486 AT+NWKSKEY=AA CC B0 20 30 45 37 32 14 1E 14 93 E2 3B 20 11 487 -))) 488 488 489 -((( 490 490 AT+APPSKEY=11 23 02 20 30 20 30 60 80 20 20 30 30 20 10 10 491 -))) 492 492 493 -((( 494 494 AT+APPEUI=2C 45 47 E3 24 12 23 24 495 -))) 496 496 497 -((( 498 498 (Any combination of 16 bit codes can be used) 499 -))) 500 500 501 501 502 502 (% class="wikigeneratedid" %)