Changes for page LoRaWAN Communication Debug
Last modified by Edwin Chen on 2025/01/29 20:30
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,14 +1,12 @@ 1 -**~ Contents:** 1 +**~ Table of Contents:** 2 2 3 -((( 4 - 5 -))) 6 - 7 7 {{toc/}} 8 8 9 9 6 + 10 10 = 1. OTAA Join Process Debug = 11 11 9 + 12 12 These pages are useful to check what is wrong on the Join process. Below shows the four steps that we can check the Join Process. 13 13 \\**If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the sceenshots for each step to check. They include:** 14 14 ... ... @@ -64,6 +64,7 @@ 64 64 65 65 = 2. Notice of US915/CN470/AU915 Frequency band = 66 66 65 + 67 67 ((( 68 68 If user has problem to work with lorawan server in band US915/AU915/CN470, he can check: 69 69 ))) ... ... @@ -106,10 +106,13 @@ 106 106 107 107 AU915 Channels 108 108 108 + 109 109 [[image:image-20220526163941-8.png]] 110 110 111 111 ((( 112 112 CN470 Channels 113 + 114 + 113 113 ))) 114 114 115 115 ((( ... ... @@ -120,6 +120,8 @@ 120 120 121 121 ((( 122 122 TTN FREQUENCY PLAN 125 + 126 + 123 123 ))) 124 124 125 125 ((( ... ... @@ -129,6 +129,7 @@ 129 129 130 130 = 3. Why i see data lost/unperiocially uplink data? Even the signal strength is good = 131 131 136 + 132 132 In this case, we can check if the frequency band matches in End Node, Gateway and LoRaWAN server. A typical case is using US915 in ChirpStack server as below: 133 133 134 134 * **End node** ~-~-> Use Sub-band2 (Channel 8,9,10,11,12,13,14,15) for Dragino Sensor. ADR is also enable, this is the default settings for dragino sensors. ... ... @@ -150,6 +150,7 @@ 150 150 151 151 = 4. Transmision on ABP Mode = 152 152 158 + 153 153 ((( 154 154 In ABP mode, there is a Frame Counter Checks. With this check enabled, the server will only accept the frame with a higher counter. If you reboot the device in ABP mode, the device will start from count 0, so you won't be able to see the frame update in server. 155 155 ))) ... ... @@ -179,6 +179,7 @@ 179 179 180 180 == 5.1 How it work == 181 181 188 + 182 182 LoRaWAN End node will open two receive windows to receive the downstream data. If the downstream packets arrive the end node at these receive windows, the end node will be able to get this packet and process it. 183 183 184 184 ((( ... ... @@ -185,10 +185,11 @@ 185 185 Depends on Class A or Class C, the receive windows will be a little difference, 186 186 ))) 187 187 188 -[[image:image-202205 26164547-11.png]]195 +[[image:image-20220531161828-1.png]] 189 189 190 190 receive windows for Class A and Class C 191 191 199 + 192 192 Below are the requirement for the End Device to receive the packets. 193 193 194 194 * The End Device must open the receive windows: RX1 or RX2 ... ... @@ -195,12 +195,13 @@ 195 195 * The LoRaWAN server must send a downstream packet, and the gateway forward this downstream packet for this end node. 196 196 * This downstream packet must arrive to the end node while RX1 or RX2 is open. 197 197 * This packet must match the frequency of the RX1 or RX2 window. 198 -* This packet must match the DataRate of RX1(RX1DR) or RX2 (RX2DR). **This is the common fail point, because different lorawan server might use different RX2DR and they don't info End Node via ADR message so cause the mismatch. If this happen, user need to change the RX2DR to the right value in end node. In OTAA, LoRaWAN Server will send the RX2DR setting in Join Accept message so the end node will auto adjust. but ABP uplink doesn't support this auto change.** 206 +* This packet must match the DataRate of RX1(RX1DR) or RX2 (RX2DR). (% style="color:red" %)**This is the common fail point, because different lorawan server might use different RX2DR and they don't info End Node via ADR message so cause the mismatch. If this happen, user need to change the RX2DR to the right value in end node. In OTAA, LoRaWAN Server will send the RX2DR setting in Join Accept message so the end node will auto adjust. but ABP uplink doesn't support this auto change.** 199 199 200 200 == 5.2 See Debug Info == 201 201 210 + 202 202 ((( 203 -**For LoRaWAN Server** 212 +(% style="color:blue" %)**For LoRaWAN Server** 204 204 ))) 205 205 206 206 ((( ... ... @@ -230,7 +230,7 @@ 230 230 231 231 232 232 ((( 233 -**For LoRaWAN Gateway** 242 +(% style="color:blue" %)**For LoRaWAN Gateway** 234 234 ))) 235 235 236 236 ((( ... ... @@ -245,7 +245,7 @@ 245 245 246 246 247 247 ((( 248 -**For End Node** 257 +(% style="color:blue" %)**For End Node** 249 249 ))) 250 250 251 251 ((( ... ... @@ -253,23 +253,18 @@ 253 253 ))) 254 254 255 255 ((( 265 +(% style="color:#037691" %)**AT+RX2FQ=869525000** (%%) **~-~-->** The RX2 Window frequency 266 +(% style="color:#037691" %)**AT+RX2DR=3** (%%) **~-~-->** The RX2 DataRate 267 +(% style="color:#037691" %)**AT+RX1DL=1000** (%%) ** ~-~-->** Receive Delay 1 268 +(% style="color:#037691" %)**AT+RX2DL=2000** (%%) **~-~--> ** Receive Delay 2 269 + 256 256 257 257 ))) 258 258 259 259 ((( 260 -(% class="box infomessage" %) 261 -((( 262 -AT+RX2FQ=869525000 ~-~--> The RX2 Window frequency 263 -AT+RX2DR=3 ~-~--> The RX2 DataRate 264 -AT+RX1DL=1000 ~-~--> Receive Delay 1 265 -AT+RX2DL=2000 ~-~--> Receive Delay 2 274 +(% style="color:blue" %)**when the device running, we can see below info:** 266 266 ))) 267 -))) 268 268 269 -((( 270 -**when the device running, we can see below info:** 271 -))) 272 - 273 273 {{{ [12502]***** UpLinkCounter= 0 ***** 274 274 [12503]TX on freq 868500000 Hz at DR 0 275 275 [13992]txDone ... ... @@ -283,7 +283,7 @@ 283 283 ))) 284 284 285 285 ((( 286 -**Another message:** 290 +(% style="color:blue" %)**Another message:** 287 287 ))) 288 288 289 289 {{{ [12502]***** UpLinkCounter= 0 ***** ... ... @@ -298,8 +298,9 @@ 298 298 1:0012345678}}} 299 299 300 300 301 -== 5.3 If problem doesn ’t solve ==305 +== 5.3 If problem doesn't solve == 302 302 307 + 303 303 (% style="color:red" %)**If user has checked below steps and still can't solve the problem, please send us (support @ dragino.com) the sceenshots for each step to check. They include:** 304 304 305 305 * End node console to show the transmit freuqency and DR. ... ... @@ -307,8 +307,11 @@ 307 307 * Gateway traffic (from server UI) to shows the data exchange between gateway and server. 308 308 * End Node traffic (from server UI) to shows end node activity in server. 309 309 315 + 316 + 310 310 = 6. Downlink Issue ~-~- Packet REJECTED, unsupported frequency = 311 311 319 + 312 312 ((( 313 313 In LoRaWAN, the gatewat will use the frequency specify by the server to transmit a packet as downlink purpose. Each Frequency band has different downlink frequency. and the gateway has a frequency range limited to transmit downlink. 314 314 ))) ... ... @@ -334,27 +334,17 @@ 334 334 335 335 = 7. Decrypt a LoRaWAN Packet = 336 336 337 -~1. LHT65 End device configure: 338 338 339 -(% class="box infomessage" %) 340 -((( 341 -**Change to ABP Mode: AT+NJM=0** 342 -))) 346 +(% style="color:blue" %)**1. LHT65 End device configure:** 343 343 344 -(% class="box infomessage" %) 345 -((( 346 -**Change to fix frequency: AT+CHS=904900000** 347 -))) 348 +**Change to ABP Mode: AT+NJM=0** 349 +**Change to fix frequency: AT+CHS=904900000** 350 +**Change to fix DR: AT+DR=0** 348 348 349 -(% class="box infomessage" %) 350 -((( 351 -**Change to fix DR: AT+DR=0** 352 -))) 353 - 354 354 [[image:image-20220526165525-16.png]] 355 355 356 356 357 -2. In LG02 , configure to receive above message 355 +(% style="color:blue" %)**2. In LG02 , configure to receive above message** 358 358 359 359 [[image:image-20220526165612-17.png]] 360 360 ... ... @@ -364,7 +364,7 @@ 364 364 [[image:image-20220526171112-21.png]] 365 365 366 366 367 -3. Decode the info in web 365 +(% style="color:blue" %)**3. Decode the info in web** 368 368 369 369 [[https:~~/~~/lorawan-packet-decoder-0ta6puiniaut.runkit.sh>>url:https://lorawan-packet-decoder-0ta6puiniaut.runkit.sh/]] 370 370 ... ... @@ -376,6 +376,7 @@ 376 376 377 377 AT+APPSKEY=00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 11 (End Node App Session Key) 378 378 377 + 379 379 [[https:~~/~~/lorawan-packet-decoder-0ta6puiniaut.runkit.sh/?data=40c1190126800100024926272bf18bbb6341584e27e23245&nwkskey=00000000000000000000000000000111&appskey=00000000000000000000000000000111>>url:https://lorawan-packet-decoder-0ta6puiniaut.runkit.sh/?data=40c1190126800100024926272bf18bbb6341584e27e23245&nwkskey=00000000000000000000000000000111&appskey=00000000000000000000000000000111]] 380 380 381 381 [[image:image-20220526171029-20.png]] ... ... @@ -387,13 +387,15 @@ 387 387 388 388 = 8. Why i see uplink 0x00 periodcally on the LHT65 v1.8 firmware = 389 389 389 + 390 390 Since firmware v1.8, LHT65 will send MAC command to request time, in the case if DR only support max 11 bytes, this MAC command will be bundled to a separate uplink payload with 0x00. 391 391 392 392 393 393 = 9. Why do I see a "MIC Mismatch" error message from the server? = 394 394 395 + 395 395 ((( 396 -1)If the user receives a "MIC Mismatch" message after registering the node on the server. 397 +1) If the user receives a "MIC Mismatch" message after registering the node on the server. 397 397 ))) 398 398 399 399 ((( ... ... @@ -415,11 +415,14 @@ 415 415 * ((( 416 416 If a node is registered with multiple servers, it may also cause the "mic mismatch" error. 417 417 419 + 420 + 418 418 419 419 ))) 420 420 421 421 = 10. Why i got the payload only with "0x00" or "AA~=~="? = 422 422 426 + 423 423 * If you are using US915, AU915 and AS923 frequencies.This is normal phenomenon. 424 424 425 425 ((( ... ... @@ -437,38 +437,78 @@ 437 437 Some node decoders may not have filtering function, or you need decoders of other servers and formats. Please send an email to [[david.huang@dragino.cc>>mailto:david.huang@dragino.cc]] 438 438 439 439 444 + 440 440 441 441 ))) 442 442 443 443 = 11. Why my Dev EUI and APP EUI is 0x000000000000, how to solve? = 444 444 450 + 451 +((( 445 445 It is possible the keys is erased during upgrading of firmware. and the console output shows below after AT+CFG 453 +))) 446 446 455 +((( 447 447 AT+APPKEY=00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 457 +))) 448 448 459 +((( 449 449 AT+NWKSKEY=00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 461 +))) 450 450 463 +((( 451 451 AT+APPSKEY=00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 465 +))) 452 452 467 +((( 453 453 AT+APPEUI=00 00 00 00 00 00 00 00 469 +))) 454 454 471 +((( 472 + 473 +))) 455 455 475 +((( 456 456 You can get the keys from the box sticker or send mail to Dragino Support to check keys with the provided SN number. 477 +))) 457 457 479 +((( 458 458 You can rewrites the keys by running commands in AT Console 459 459 460 -For example: 482 + 483 +))) 461 461 485 +((( 486 +**For example:** 487 +))) 488 + 489 +((( 462 462 AT+APPKEY=85 41 47 20 45 58 28 14 16 82 A0 F0 80 0D DD EE 491 +))) 463 463 493 +((( 464 464 AT+NWKSKEY=AA CC B0 20 30 45 37 32 14 1E 14 93 E2 3B 20 11 495 +))) 465 465 497 +((( 466 466 AT+APPSKEY=11 23 02 20 30 20 30 60 80 20 20 30 30 20 10 10 499 +))) 467 467 501 +((( 468 468 AT+APPEUI=2C 45 47 E3 24 12 23 24 503 +))) 469 469 505 +((( 470 470 (Any combination of 16 bit codes can be used) 471 471 472 472 509 += 12. I set my device is LoRaWAN Class C mode, why i still see Class A after boot? = 510 +))) 511 + 512 + 513 +Class C only refers to status after OTAA Join successfully. The OTAA Join Process will use Class A mode. 514 + 515 + 516 + 473 473 (% class="wikigeneratedid" %) 474 474
- image-20220531161828-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +98.6 KB - Content