From version < 4.1 >
edited by Edwin Chen
on 2022/05/12 11:15
To version < 9.2 >
edited by Xiaoling
on 2022/05/12 11:50
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -2,37 +2,23 @@
2 2  
3 3  = 1. Introduction =
4 4  
5 -This chapter describes how to set Transmit Time Interva[[l for Dragino Senso>>https://End Device AT Commands and Downlink Command/#H4.1ChangeUplinkInterval]]rs.
5 +This chapter describes how to set Transmit Time Interval.
6 6  
7 -= 2. via AT Command through UART interface =
7 += 2. Downlink Payload =
8 8  
9 -
10 -
11 -(% class="wikigeneratedid" %)
12 -= 3. via LoRaWAN Downlink =
13 -
14 14  TDC can be controlled by Downlink Payload.
15 15  
16 -(((
17 17  For example: AT+TDC=0x258=600s Payload: 01 00 02 58 TDC=600s The time interval is represented by hexadecimal conversion to decimal.
18 -)))
19 19  
20 20  [[image:https://wiki.dragino.com/images/8/8e/TDC.png||alt="TDC.png" height="173" width="850"]]
21 21  
22 -(((
23 -
24 -)))
25 25  
26 -(((
27 27  If the payload=0100003C, it means set the END Node’s TDC to 0x00003C=60(S), 3C (HEX) = 60 (decimal),while type code is 01.
28 -)))
29 29  
30 -(((
31 31  Payload: 01 00 00 1E TDC=30s Payload: 01 00 00 3C TDC=60s
32 -)))
33 33  
34 -[[image:image-20220512084801-1.png]]
20 +[[image:https://wiki.dragino.com/images/3/38/Downlink_playload_TDC.png||alt="Downlink playload TDC.png" height="304" width="910"]]
35 35  
36 -= 3. Downlink Method =
22 +== 3. Downlink Method ==
37 37  
38 38  See use note for different serves [[Servers Note>>http://8.211.40.43:8080/xwiki/bin/view/Main/]]
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved