... ... @@ -55,9 +55,32 @@ 55 55 ))) 56 56 57 57 58 -= 4. Case 3: Standard LoRaWAN connection~-~- wit houtLoRaWAN server,useABP LoRaWANEndnode =58 += 4. Case 3: Standard LoRaWAN connection~-~- use Gateway built-in LoRaWAN server to connect to external IoT server = 59 59 60 +**Application Scenario**: 60 60 62 +* There is already IoT server but no LoRaWAN server. 63 +* Not willing to use public LoRaWAN server nor built own LoRaWAN server. 64 +* 65 + 66 + 67 +**Suitable Gateway:** 68 + 69 +* LoRaWAN Gateway model: LPS8v2. 70 + 71 + 72 +**How it works:** 73 + 74 +* a) LPS8v2 already includes a LoRaWAN server (TTN Stack v3). Enable this server in Web UI. 75 +* b) Input End Nodes keys in LPS8v2 LoRaWAN server. 76 +* c) Configure LPS8v2, End Node and LoRaWAN server frequency plan. 77 +* d) Configure local LoRaWAN server to forward data to external Application Server. 78 + 79 +[[image:image-20220626095429-4.png||height="523" width="864"]] 80 + 81 + 82 + 83 + 61 61 = 5. Case 4: Standard LoRaWAN connection~-~- without LoRaWAN server, use ABP LoRaWAN End node = 62 62 63 63 Below gateways support this mode:
- image-20220626095429-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +170.2 KB - Content