Table of Contents:

1. Instroduction

This charpter shows how to customized the frequency bands for the LoRaWAN gateway. Support below models:

2. Configuration Step by Steps

2.1 Determine the frequency band to be set

For example, we want to set the gateway to work for below frequency band

image-20220527165508-1.png

Determine what is the frequency to be used

2.2 Find suitable centra frequency

In the gateway, there are two radios: Radio0 and Radio1. We can configure the frequency at the ±400000hz range base on these two Radios. In this case, we can set: Radio0 = 865700000 and Radio1 = 866500000. And the eight frequency we need are:

  • Channel 0 frequency = radio0 – 300000Hz = 865700000 - 300000 = 865.4 Mhz
  • Channel 1 frequency = radio0 – 100000Hz = 865700000 - 100000 = 865.6 Mhz
  • Channel 2 frequency = radio0 + 100000Hz = 865700000 + 100000 = 865.8 Mhz
  • Channel 3 frequency = radio0 + 300000Hz = 865700000 + 300000 = 866.0 Mhz
  • Channel 4 frequency = radio1 - 300000Hz = 866500000 - 300000 = 866.2 Mhz
  • Channel 5 frequency = radio1 - 100000Hz = 866500000 - 100000 = 866.4 Mhz
  • Channel 6 frequency = radio1 + 100000Hz = 866500000 + 100000 = 866.6 Mhz
  • Channel 7 frequency = radio1 + 300000Hz = 866500000 + 300000 = 866.8 Mhz
  • Channel LoRaSTD frequency= 865.7Mhz, SF7, BW250Khz

2.3 Configure the Web

image-20220527165612-2.png

Choose Customized Band

image-20220527165718-3.png

Configure Frequency

image-20220527165755-4.png

Verify Settings