Last modified by Xiaoling on 2024/08/19 16:13

From version 2.1
edited by Xiaoling
on 2022/05/17 15:42
Change comment: There is no comment for this version
To version 15.8
edited by Xiaoling
on 2022/08/09 10:20
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,8 +1,12 @@
1 -(((
2 -AT+CGDCONT Define a PDP Context
3 -)))
1 +**Table of Contents: **
4 4  
5 5  (((
4 +{{toc/}}
5 +
6 +
7 +
8 += 1.  AT+CGDCONT Define a PDP Context =
9 +
6 6  
7 7  )))
8 8  
... ... @@ -11,42 +11,22 @@
11 11  )))
12 12  
13 13  (((
14 -
15 -)))
16 -
17 -(((
18 18  For EPS, the PDN connection and its associated EPS default bearer is identified herewith.
19 19  )))
20 20  
21 21  (((
22 -
23 -)))
24 -
25 -(((
26 26  A special form of the write command, AT+CGDCONT=<cid> causes the values for context number <cid> to become undefined.
27 27  )))
28 28  
29 29  (((
30 -
31 -)))
32 -
33 -(((
34 34  If the initial PDP context is supported, the context with <cid>=0 is automatically defined at startup, the parameters for <cid>=0 can be modified with AT+CGDCONT. If the initial PDP context is supported, AT+CGDCONT=0 resets context number 0 to its particular default settings.
35 35  )))
36 36  
37 37  (((
38 -
39 -)))
40 -
41 -(((
42 42  The read command returns the current settings for each defined context.
43 43  )))
44 44  
45 45  (((
46 -
47 -)))
48 -
49 -(((
50 50  The test command returns values supported as compound values. If the UE supports several PDP types, the parameter value ranges for each <PDP_type> are returned on a separate line.
51 51  )))
52 52  
... ... @@ -54,22 +54,26 @@
54 54  
55 55  )))
56 56  
57 -[[image:https://wiki.dragino.com/images/thumb/a/ab/APN1.png/600px-APN1.png||height="566" width="600"]]
41 +[[image:image-20220530095114-1.png]]
58 58  
59 59  COMMAND
60 60  
61 -[[image:https://wiki.dragino.com/images/thumb/0/0c/APN2.png/600px-APN2.png||height="488" width="600"]]
62 62  
46 +[[image:image-20220530095214-2.png]]
47 +
63 63  Parameter
64 64  
65 -**Example:**
66 66  
67 67  (((
52 +(% style="color:blue" %)**Example:**
53 +)))
54 +
55 +(((
68 68  AT+CGDCONT=?
69 69  )))
70 70  
71 71  (((
72 -+CGDCONT:(0-10),("IP","NONIP","IPV6","IPV4V6")~,~,,(0),(0)~,~,~,~,,(0,1)
60 ++CGDCONT: (0-10),("IP","NONIP","IPV6","IPV4V6")~,~,,(0),(0)~,~,~,~,,(0,1)
73 73  OK
74 74  )))
75 75  
... ... @@ -96,3 +96,25 @@
96 96  (((
97 97  OK
98 98  )))
87 +
88 +
89 +
90 += 2.  Quit AT Command =
91 +
92 +
93 +Feature: Quit AT Command mode, so user needs to input the password again before using AT Commands.
94 +
95 +
96 +(% class="box infomessage" %)
97 +(((
98 +**AT Command: AT+DISAT**
99 +)))
100 +
101 +(% border="1" style="background-color:#ffffcc; color:green; width:450px" %)
102 +|=**Command Example**|=**Function**|=**Response**
103 +|AT+DISAT|Quit AT Commands mode|OK
104 +
105 +
106 +**Downlink Command:**
107 +
108 +No downlink command for this feature.
image-20220530095114-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +77.3 KB
Content
image-20220530095214-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +164.1 KB
Content