Changes for page General Manual for -CB , -CS models
Last modified by Mengting Qiu on 2025/07/03 18:49
From version 144.4
edited by Mengting Qiu
on 2025/07/03 18:37
on 2025/07/03 18:37
Change comment:
There is no comment for this version
To version 144.13
edited by Mengting Qiu
on 2025/07/03 18:43
on 2025/07/03 18:43
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1019,22 +1019,15 @@ 1019 1019 1020 1020 //Example~:// For the S31-CB's uplink interval modification (AT+TDC=900): 1021 1021 1022 -* HEX format: (% style="color:blue" %)**01000384**(%%) ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds. 1023 -* JSON format: (% style="color:blue" %)**{AT+TDC=900}**(%%)** **~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}. 1022 +Downlink command: (% style="color:blue" %)**01000384**(%%) ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds. 1024 1024 1025 -(% style="color:red" %)**Note:** 1026 1026 1027 -(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.** 1028 - 1029 -(% style="color:red" %)**2. Devices designed with downlink commands can utilize different downlink formats (e.g., JSON or HEX) for configuration. However, regardless of the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.** 1030 - 1031 -(% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.** 1032 - 1033 - 1034 1034 ==== **2. JSON-format ** ==== 1035 1035 1036 - All -CB nodes support downlink configuration modification using (% style="color:blue"%)**0**(%%)JSON format templates.1027 +===== **2. 1 JSON format template.** ===== 1037 1037 1029 +All -CB nodes support downlink configuration modification using (% style="color:blue" %)**JSON format templates.** 1030 + 1038 1038 We can use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device. 1039 1039 Template. 1040 1040 ... ... @@ -1080,9 +1080,13 @@ 1080 1080 1081 1081 1082 1082 1076 +===== **2.2 Support sending json format commands separately** ===== 1083 1083 1078 +Some models of nodes support sending json format commands separately:(% style="color:blue" %)**RS485-CB, LDS25-CB, CS01-CB, SDI-12-CB, SW3L-CB, WL03A-CB, PS-CB** 1084 1084 1080 +//Example~:// For the PS-CB's uplink interval modification (AT+TDC=900): 1085 1085 1082 +Downlink command: (% style="color:blue" %)**{AT+TDC=900}**(%%)** **~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}. 1086 1086 1087 1087 1088 1088