Changes for page General Manual for -CB , -CS models
Last modified by Mengting Qiu on 2025/07/03 18:49
From version 143.2
edited by Mengting Qiu
on 2025/07/03 18:27
on 2025/07/03 18:27
Change comment:
There is no comment for this version
To version 144.12
edited by Mengting Qiu
on 2025/07/03 18:41
on 2025/07/03 18:41
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1019,7 +1019,8 @@ 1019 1019 1020 1020 //Example~:// For the S31-CB's uplink interval modification (AT+TDC=900): 1021 1021 1022 -* HEX format: (% style="color:blue" %)**01000384**(%%) ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds. 1022 +HEX format: (% style="color:blue" %)**01000384**(%%) ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds. 1023 + 1023 1023 * JSON format: (% style="color:blue" %)**{AT+TDC=900}**(%%)** **~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}. 1024 1024 1025 1025 (% style="color:red" %)**Note:** ... ... @@ -1031,13 +1031,17 @@ 1031 1031 (% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.** 1032 1032 1033 1033 1035 +==== **2. JSON-format ** ==== 1034 1034 1037 +===== **2. 1 JSON format template.** ===== 1035 1035 1036 - **TemplateforBatchConfiguration:**1039 +All -CB nodes support downlink configuration modification using (% style="color:blue" %)**JSON format templates.** 1037 1037 1038 -We can alsouse templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device.1039 -Template :1041 +We can use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device. 1042 +Template. 1040 1040 1044 +Take the template of DDS75-CB as an example: 1045 + 1041 1041 { 1042 1042 "AT+SERVADDR":"119.91.62.30,1882", 1043 1043 "AT+CLIENT":"JwcXKjQBNhQ2JykDDAA5Ahs", ... ... @@ -1050,17 +1050,22 @@ 1050 1050 "AT+APN":"NULL", 1051 1051 "AT+5VT":"0", 1052 1052 "AT+PRO":"3,5", 1053 -"AT+TR":" 900",1054 -"AT+NOUD":" 0",1058 +"AT+TR":"15", 1059 +"AT+NOUD":"8", 1055 1055 "AT+CSQTIME":"5", 1056 -"AT+DNS TIMER":"0",1061 +"AT+GDNS":"0", 1057 1057 "AT+TLSMOD":"0,0", 1058 1058 "AT+MQOS":"0", 1059 -"AT+TEMPALARM1":"0", 1060 -"AT+TEMPALARM2":"10", 1061 -"AT+TEMPALARM3":"0" 1064 +"AT+IPTYPE":"0", 1065 +"AT+GTDC":"0", 1066 +"AT+GNSST":"10", 1067 +"AT+GPS":"0" 1062 1062 } 1063 1063 1070 +Explanations of two special commands in the template: AT+TR (set the detection interval: 0 ~~ 255 minutes) and AT+NOUD (set the number of groups) correspond to parameters in AT+CLOCKLOG. 1071 + 1072 +[[image:1751538862245-924.png]] 1073 + 1064 1064 **Instructions for Using the Template:** 1065 1065 1066 1066 1. Modify the parameters for each AT command in the template as needed. ... ... @@ -1073,6 +1073,15 @@ 1073 1073 1074 1074 1075 1075 1086 +===== **2.2 Support sending json format commands separately** ===== 1087 + 1088 +Some models of nodes support sending json format commands separately:(% style="color:blue" %)**RS485-CB, LDS25-CB, CS01-CB, SDI-12-CB, SW3L-CB, WL03A-CB, PS-CB** 1089 + 1090 +//Example~:// For the PS-CB's uplink interval modification (AT+TDC=900): 1091 + 1092 + 1093 + 1094 + 1076 1076 == 7.4 What if the signal is good but the domain name resolution fails? == 1077 1077 1078 1078
- 1751538862245-924.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +114.7 KB - Content