Changes for page General Manual for -CB , -CS models
Last modified by Mengting Qiu on 2025/06/18 15:53
From version 143.1
edited by Mengting Qiu
on 2025/06/18 15:53
on 2025/06/18 15:53
Change comment:
There is no comment for this version
To version 141.10
edited by Mengting Qiu
on 2025/06/16 10:14
on 2025/06/16 10:14
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -982,7 +982,7 @@ 982 982 983 983 * Does your SIM card support NB-IoT network? If SIM card doesn't not specify support NB-IoT clearly, normally it doesn't support. You need to confirm with your operator. 984 984 * Do you configure the correct APN? [[Check here for APN settings>>http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H2.1GeneralConfiguretoattachnetwork]]. 985 -* Do you lock the frequency band? This is the most case we see. [[Explain and Instruction>> ||anchor="H1.ConfigureFrequencyBand"]].985 +* Do you lock the frequency band? This is the most case we see. [[Explain and Instruction>>http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H2.2SpeedUpNetworkAttachtime]]. 986 986 * Check if the device is attached to Carrier network but reject. (need to check with operator). 987 987 * Check if the antenna is connected firmly. 988 988 ... ... @@ -1018,7 +1018,7 @@ 1018 1018 //Example~:// For the S31-CB's uplink interval modification (AT+TDC=900): 1019 1019 1020 1020 * HEX format: (% style="color:blue" %)**01000384**(%%) ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds. 1021 -* JSON format: (% style="color:blue" %)**{AT+TDC=900}**(%%)** 1021 +* JSON format: (% style="color:blue" %)**{AT+TDC=900}**(%%)** **~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}. 1022 1022 1023 1023 (% style="color:red" %)**Note:** 1024 1024 ... ... @@ -1029,9 +1029,12 @@ 1029 1029 (% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.** 1030 1030 1031 1031 1032 -**Template for Batch Configuration:** 1033 1033 1034 -We can also use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device. 1033 + 1034 +Json: 1035 + 1036 +The Json format in MQTT mode needs to be configured with all commands. 1037 +If you have configurations that need to be changed, please change them in the template below. 1035 1035 Template: 1036 1036 1037 1037 { ... ... @@ -1057,18 +1057,16 @@ 1057 1057 "AT+TEMPALARM3":"0" 1058 1058 } 1059 1059 1060 - **Instructions for Using theTemplate:**1063 +Hex: 1061 1061 1062 -1. Modify the parameters for each AT command in the template as needed. 1063 -1. Send the entire template in one downlink command. 1065 +MQTT's hex format. Since many commands need to support strings, only a few commands are supported. 1064 1064 1065 -(% style="color:red" %)**Note:** 1067 +The supported commands are consistent with LoRaWAN's hex commands. 1068 +Please refer to the following link to obtain the hex format: 1066 1066 1067 -* The template may vary depending on the device model. 1068 -* **Currently, each specific template is being updated and tested**. If you need a template for your specific device, please contact **Dragino Technical Support** at [[support@dragino.com>>url:https://mailto:support@dragino.com/]] to request the latest downlink template. 1070 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1069 1069 1070 1070 1071 - 1072 1072 == 7.4 What if the signal is good but the domain name resolution fails? == 1073 1073 1074 1074