Changes for page General Manual for -CB , -CS models
Last modified by Mengting Qiu on 2025/06/18 15:53
From version 142.1
edited by Mengting Qiu
on 2025/06/16 10:15
on 2025/06/16 10:15
Change comment:
There is no comment for this version
To version 141.10
edited by Mengting Qiu
on 2025/06/16 10:14
on 2025/06/16 10:14
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1029,9 +1029,12 @@ 1029 1029 (% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.** 1030 1030 1031 1031 1032 -**Template for Batch Configuration:** 1033 1033 1034 -We can also use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device. 1033 + 1034 +Json: 1035 + 1036 +The Json format in MQTT mode needs to be configured with all commands. 1037 +If you have configurations that need to be changed, please change them in the template below. 1035 1035 Template: 1036 1036 1037 1037 { ... ... @@ -1057,18 +1057,16 @@ 1057 1057 "AT+TEMPALARM3":"0" 1058 1058 } 1059 1059 1060 - **Instructions for Using theTemplate:**1063 +Hex: 1061 1061 1062 -1. Modify the parameters for each AT command in the template as needed. 1063 -1. Send the entire template in one downlink command. 1065 +MQTT's hex format. Since many commands need to support strings, only a few commands are supported. 1064 1064 1065 -(% style="color:red" %)**Note:** 1067 +The supported commands are consistent with LoRaWAN's hex commands. 1068 +Please refer to the following link to obtain the hex format: 1066 1066 1067 -* The template may vary depending on the device model. 1068 -* **Currently, each specific template is being updated and tested**. If you need a template for your specific device, please contact **Dragino Technical Support** at [[support@dragino.com>>url:https://mailto:support@dragino.com/]] to request the latest downlink template. 1070 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1069 1069 1070 1070 1071 - 1072 1072 == 7.4 What if the signal is good but the domain name resolution fails? == 1073 1073 1074 1074