Changes for page General Manual for -CB , -CS models
Last modified by Mengting Qiu on 2025/06/18 15:53
From version 140.2
edited by Mengting Qiu
on 2025/06/16 10:06
on 2025/06/16 10:06
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Xiaoling - Content
-
... ... @@ -54,6 +54,7 @@ 54 54 |(% style="width:117px" %)China Mobile|(% style="width:151px" %)No need configure|(% style="width:406px" %)China Mainland, HongKong|(% style="width:351px" %) |(% style="width:120px" %) 55 55 |(% style="width:117px" %)China Telecom|(% style="width:151px" %)ctnb|(% style="width:406px" %)China Mainland|(% style="width:351px" %) |(% style="width:120px" %) 56 56 57 + 57 57 == 2.2 Speed Up Network Attach time == 58 58 59 59 ... ... @@ -723,8 +723,8 @@ 723 723 Note:The port for the COAP protocol has been fixed to 5683 724 724 725 725 726 -* AT+UR I1=11,"i"727 -* AT+UR I2=11,"Needs to be consistent with the CoAP endpoint URL in the platform"727 +* AT+URL1=11,"i" 728 +* AT+URL2=11,"Needs to be consistent with the CoAP endpoint URL in the platform" 728 728 * 729 729 730 730 -CB devices using a (% style="color:red" %)**BG95-M2**(%%) module, you need to configure (% style="color:red" %)**TWO**(%%) URL commands, ... ... @@ -731,8 +731,8 @@ 731 731 732 732 e.g. 733 733 734 -* AT+UR I1=11, "i"735 -* AT+UR I2=11,"faaaa241f-af4a-b780-4468-c671bb574858"735 +* AT+URL1=11, "i" 736 +* AT+URL2=11,"faaaa241f-af4a-b780-4468-c671bb574858" 736 736 737 737 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/WebHome/image-20240729172500-14.png?width=700&height=403&rev=1.1||alt="image-20240729172500-14.png" height="413" width="718"]] 738 738 ... ... @@ -997,19 +997,18 @@ 997 997 [[image:image-20240820113015-60.png]] 998 998 999 999 1000 -== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)7.3 (%%)What is the Downlink CommandFormatforCBDevices? ==1001 +== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)7.3 What is the Downlink Command by the -CB device?(%%) == 1001 1001 1003 +(% data-sider-select-id="bb6e9353-0c3f-473c-938d-4b416c9a03e6" %) 1004 +=== UDP: === 1002 1002 1003 -Firstly, it is recommended that users upgrade the firmware of the -CB node to the latest version, as the processing method for downlink commands varies depending on the firmware version. Below, we will introduce the latest downlink command format. 1006 +(% data-sider-select-id="14a4790e-7faa-4508-a4dd-7605a53f1cb3" %) 1007 +Its downlink command is the same as the AT command, but brackets are required. 1008 +Example: 1004 1004 1005 - === **UDP Protocol:**===1010 +{AT+TDC=300} 1006 1006 1007 -Only supports valid **HEX-format downlink commands** corresponding to AT command. 1008 1008 1009 -Take the AT+TDC command of S31-NB as an example, that is, only the valid HEX format downstream command corresponding to the AT+TDC command can be used: 1010 -Downward format: (% style="color:blue" %)**01000384**(%%) ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds. 1011 - 1012 - 1013 1013 (% data-sider-select-id="90b80f1a-e924-4c8a-afc5-4429e019a657" %) 1014 1014 === MQTT: === 1015 1015 ... ... @@ -1189,13 +1189,4 @@ 1189 1189 AT+IPTYPE can only be configured as 1 or 2. 1190 1190 If it is configured otherwise, this error will occur** 1191 1191 1192 - 1193 -== 7.7 How to get the debug log for further analyze? == 1194 - 1195 - 1196 -CB model use the same debug instruction as NB model. Please check this link: 1197 - 1198 -**[[How to Get Full Log>>https://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H6.6Howtogetthedebuglogforfurtheranalyze3F]]**? 1199 - 1200 - 1201 1201