Changes for page General Manual for -CB , -CS models
Last modified by Mengting Qiu on 2025/06/18 15:53
From version 138.1
edited by Xiaoling
on 2025/01/13 11:31
on 2025/01/13 11:31
Change comment:
There is no comment for this version
To version 141.3
edited by Mengting Qiu
on 2025/06/16 10:12
on 2025/06/16 10:12
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.ting - Content
-
... ... @@ -54,7 +54,6 @@ 54 54 |(% style="width:117px" %)China Mobile|(% style="width:151px" %)No need configure|(% style="width:406px" %)China Mainland, HongKong|(% style="width:351px" %) |(% style="width:120px" %) 55 55 |(% style="width:117px" %)China Telecom|(% style="width:151px" %)ctnb|(% style="width:406px" %)China Mainland|(% style="width:351px" %) |(% style="width:120px" %) 56 56 57 - 58 58 == 2.2 Speed Up Network Attach time == 59 59 60 60 ... ... @@ -724,8 +724,8 @@ 724 724 Note:The port for the COAP protocol has been fixed to 5683 725 725 726 726 727 -* AT+UR L1=11,"i"728 -* AT+UR L2=11,"Needs to be consistent with the CoAP endpoint URL in the platform"726 +* AT+URI1=11,"i" 727 +* AT+URI2=11,"Needs to be consistent with the CoAP endpoint URL in the platform" 729 729 * 730 730 731 731 -CB devices using a (% style="color:red" %)**BG95-M2**(%%) module, you need to configure (% style="color:red" %)**TWO**(%%) URL commands, ... ... @@ -732,8 +732,8 @@ 732 732 733 733 e.g. 734 734 735 -* AT+UR L1=11, "i"736 -* AT+UR L2=11,"faaaa241f-af4a-b780-4468-c671bb574858"734 +* AT+URI1=11, "i" 735 +* AT+URI2=11,"faaaa241f-af4a-b780-4468-c671bb574858" 737 737 738 738 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/WebHome/image-20240729172500-14.png?width=700&height=403&rev=1.1||alt="image-20240729172500-14.png" height="413" width="718"]] 739 739 ... ... @@ -998,21 +998,40 @@ 998 998 [[image:image-20240820113015-60.png]] 999 999 1000 1000 1001 -== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)7.3 What is the Downlink Command bythe-CBdevice?(%%)==1000 +== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)7.3 (%%)What is the Downlink Command Format for CB Devices? == 1002 1002 1003 -(% data-sider-select-id="bb6e9353-0c3f-473c-938d-4b416c9a03e6" %) 1004 -=== UDP: === 1005 1005 1006 -(% data-sider-select-id="14a4790e-7faa-4508-a4dd-7605a53f1cb3" %) 1007 -Its downlink command is the same as the AT command, but brackets are required. 1008 -Example: 1003 +Firstly, it is recommended that users upgrade the firmware of the -CB node to the latest version, as the processing method for downlink commands varies depending on the firmware version. Below, we will introduce the latest downlink command format. 1009 1009 1010 - {AT+TDC=300}1005 +=== **UDP Protocol:** === 1011 1011 1007 +Only supports valid **HEX-format downlink commands** corresponding to AT command. 1012 1012 1013 - (% data-sider-select-id="90b80f1a-e924-4c8a-afc5-4429e019a657"%)1014 -= ==MQTT:===1009 +Take the AT+TDC command of S31-NB as an example, that is, only the valid HEX format downstream command corresponding to the AT+TDC command can be used: 1010 +Downward format: (% style="color:blue" %)**01000384**(%%) ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds. 1015 1015 1012 +[[image:1750039871468-460.png||height="299" width="600"]] 1013 + 1014 +=== **MQTT Protocol:** === 1015 + 1016 +Supports both **JSON-format** and **HEX-format** downlink commands (corresponding to AT commands). 1017 + 1018 +//Example~:// For the S31-NB's uplink interval modification (AT+TDC=900): 1019 + 1020 +* HEX format: **01000384** ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds. 1021 +* JSON format: **{AT+TDC=900} **~/~/ The correct format is **{AT Command}**. No extra characters other than valid AT commands can be added within {}. 1022 + 1023 +**Note:** 1024 + 1025 +**~1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.** 1026 + 1027 +**2. Devices designed with downlink commands can utilize different downlink formats (e.g., JSON or HEX) for configuration. However, regardless of the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.** 1028 + 1029 +**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.** 1030 + 1031 + 1032 + 1033 + 1016 1016 Json: 1017 1017 1018 1018 The Json format in MQTT mode needs to be configured with all commands. ... ... @@ -1189,4 +1189,13 @@ 1189 1189 AT+IPTYPE can only be configured as 1 or 2. 1190 1190 If it is configured otherwise, this error will occur** 1191 1191 1210 + 1211 +== 7.7 How to get the debug log for further analyze? == 1212 + 1213 + 1214 +CB model use the same debug instruction as NB model. Please check this link: 1215 + 1216 +**[[How to Get Full Log>>https://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H6.6Howtogetthedebuglogforfurtheranalyze3F]]**? 1217 + 1218 + 1192 1192
- 1750039871468-460.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +53.9 KB - Content