Changes for page General Manual for -CB , -CS models
Last modified by Mengting Qiu on 2025/06/18 15:53
From version 138.1
edited by Xiaoling
on 2025/01/13 11:31
on 2025/01/13 11:31
Change comment:
There is no comment for this version
To version 140.2
edited by Mengting Qiu
on 2025/06/16 10:06
on 2025/06/16 10:06
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.ting - Content
-
... ... @@ -54,7 +54,6 @@ 54 54 |(% style="width:117px" %)China Mobile|(% style="width:151px" %)No need configure|(% style="width:406px" %)China Mainland, HongKong|(% style="width:351px" %) |(% style="width:120px" %) 55 55 |(% style="width:117px" %)China Telecom|(% style="width:151px" %)ctnb|(% style="width:406px" %)China Mainland|(% style="width:351px" %) |(% style="width:120px" %) 56 56 57 - 58 58 == 2.2 Speed Up Network Attach time == 59 59 60 60 ... ... @@ -724,8 +724,8 @@ 724 724 Note:The port for the COAP protocol has been fixed to 5683 725 725 726 726 727 -* AT+UR L1=11,"i"728 -* AT+UR L2=11,"Needs to be consistent with the CoAP endpoint URL in the platform"726 +* AT+URI1=11,"i" 727 +* AT+URI2=11,"Needs to be consistent with the CoAP endpoint URL in the platform" 729 729 * 730 730 731 731 -CB devices using a (% style="color:red" %)**BG95-M2**(%%) module, you need to configure (% style="color:red" %)**TWO**(%%) URL commands, ... ... @@ -732,8 +732,8 @@ 732 732 733 733 e.g. 734 734 735 -* AT+UR L1=11, "i"736 -* AT+UR L2=11,"faaaa241f-af4a-b780-4468-c671bb574858"734 +* AT+URI1=11, "i" 735 +* AT+URI2=11,"faaaa241f-af4a-b780-4468-c671bb574858" 737 737 738 738 [[image:https://wiki.dragino.com/xwiki/bin/download/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/WebHome/image-20240729172500-14.png?width=700&height=403&rev=1.1||alt="image-20240729172500-14.png" height="413" width="718"]] 739 739 ... ... @@ -998,18 +998,19 @@ 998 998 [[image:image-20240820113015-60.png]] 999 999 1000 1000 1001 -== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)7.3 What is the Downlink Command bythe-CBdevice?(%%)==1000 +== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)7.3 (%%)What is the Downlink Command Format for CB Devices? == 1002 1002 1003 -(% data-sider-select-id="bb6e9353-0c3f-473c-938d-4b416c9a03e6" %) 1004 -=== UDP: === 1005 1005 1006 -(% data-sider-select-id="14a4790e-7faa-4508-a4dd-7605a53f1cb3" %) 1007 -Its downlink command is the same as the AT command, but brackets are required. 1008 -Example: 1003 +Firstly, it is recommended that users upgrade the firmware of the -CB node to the latest version, as the processing method for downlink commands varies depending on the firmware version. Below, we will introduce the latest downlink command format. 1009 1009 1010 - {AT+TDC=300}1005 +=== **UDP Protocol:** === 1011 1011 1007 +Only supports valid **HEX-format downlink commands** corresponding to AT command. 1012 1012 1009 +Take the AT+TDC command of S31-NB as an example, that is, only the valid HEX format downstream command corresponding to the AT+TDC command can be used: 1010 +Downward format: (% style="color:blue" %)**01000384**(%%) ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds. 1011 + 1012 + 1013 1013 (% data-sider-select-id="90b80f1a-e924-4c8a-afc5-4429e019a657" %) 1014 1014 === MQTT: === 1015 1015 ... ... @@ -1189,4 +1189,13 @@ 1189 1189 AT+IPTYPE can only be configured as 1 or 2. 1190 1190 If it is configured otherwise, this error will occur** 1191 1191 1192 + 1193 +== 7.7 How to get the debug log for further analyze? == 1194 + 1195 + 1196 +CB model use the same debug instruction as NB model. Please check this link: 1197 + 1198 +**[[How to Get Full Log>>https://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#H6.6Howtogetthedebuglogforfurtheranalyze3F]]**? 1199 + 1200 + 1192 1192