Last modified by Kilight Cao on 2025/07/23 16:27

From version 233.1
edited by Mengting Qiu
on 2025/07/03 18:55
Change comment: There is no comment for this version
To version 235.1
edited by Kilight Cao
on 2025/07/23 16:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.ting
1 +XWiki.Kilight
Content
... ... @@ -394,6 +394,61 @@
394 394  (% style="color:blue" %)**AT+SERVADDR=67.207.76.90,4445**
395 395  
396 396  
397 +== 3.5 Telemetry2U ==
398 +
399 +
400 +=== Configuring the Dragino NB Sensor Settings ===
401 +
402 +
403 +(% style="color:blue" %)**AT+SERVADDR=telemetry2u.com,4483**(%%) – Sets the server address and port for sending data to the Telemetry2U IoT platform.
404 +
405 +(% style="color:blue" %)**AT+APN=simbase**(%%) – Sets the APN required for LTE-M connectivity using a Simbase global SIM card.
406 +
407 +(% style="color:blue" %)**ATZ**(%%) – Reboots the device to apply the changes. It won’t transmit to Telemetry2U until added and configured on the platform.
408 +
409 +(% style="color:blue" %)**AT+CFG**(%%) – Displays the current configuration. Take note of the 8-byte (HEX) **DEUI**, which you’ll need in the next setup step.
410 +
411 +And that’s it! These simple steps will get your device up and running on our Telemetry2U servers in no time.
412 +
413 +
414 +**Step 1: Log in Telemetry2U**
415 +
416 +
417 +Users can register a Telemetry2U account for their first use
418 +
419 +**[[https:~~/~~/telemetry2u.com/Identity/Account/Register>>https://telemetry2u.com/Identity/Account/Register]]**
420 +
421 +
422 +**Step 2: Add the device**
423 +
424 +[[image:1753258256594-216.png||height="686" width="1382"]]
425 +
426 +
427 +**1. Select Network provide:**Users need to select Telemetry2U NB-IoT over UDP in order to connect to the platform
428 +
429 +**2. Select device type:**Select the template you need to use
430 +
431 +**3. Fill in Description:**Fill in the unique description
432 +
433 +4. **Fill in IMEI:**The IMEI corresponds to the IME of the device
434 +
435 +After completion, click "**Greate**"
436 +
437 +[[image:1753258480811-335.png||height="789" width="1380"]]
438 +
439 +
440 +**Step 3: Check the data**
441 +
442 +
443 +[[image:1753258821265-310.png||height="681" width="1365"]]
444 +
445 +
446 +
447 +For more information, please refer to the user manual on the Telemetry2U official website:
448 +
449 +**[[https:~~/~~/telemetry2u.com/Documentation/dragino-lte-m-nb-iot-sensors-iot-platform-integration>>https://telemetry2u.com/Documentation/dragino-lte-m-nb-iot-sensors-iot-platform-integration]]**
450 +
451 +
397 397  == 3.5 Node-Red (via MQTT) ==
398 398  
399 399  === 3.5.1 Configure [[Node-Red>>http://wiki.dragino.com/xwiki/bin/view/Main/Node-RED/]] ===
... ... @@ -1058,12 +1058,12 @@
1058 1058  
1059 1059  ===== **2. 1 JSON format template.** =====
1060 1060  
1061 -All -CB nodes support downlink configuration modification using (% style="color:blue" %)**JSON format templates.**
1116 +All -NB nodes support downlink configuration modification using (% style="color:blue" %)**JSON format templates.**
1062 1062  
1063 1063  We can use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device.
1064 1064  Template.
1065 1065  
1066 -Take the template of D2x-CB as an example:
1121 +Take the template of D2x-NB as an example:
1067 1067  
1068 1068  {
1069 1069  "AT+SERVADDR":"119.91.62.30,1882",
... ... @@ -1109,7 +1109,7 @@
1109 1109  
1110 1110  Some models of nodes support sending json format commands separately:(% style="color:blue" %)**RS485-NB, LDS25-NB, CS01-NB, SDI-12-NB, SW3L-NB, WL03A-NB, PS-NB, LTC2-NB.**
1111 1111  
1112 -//Example~:// For the PS-CB's uplink interval modification (AT+TDC=900):
1167 +//Example~:// For the PS-NB's uplink interval modification (AT+TDC=900):
1113 1113  
1114 1114  Downlink command:  (% style="color:blue" %)**{AT+TDC=900}**(%%)**       **~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}.
1115 1115  
1753258256594-216.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +153.1 KB
Content
1753258480811-335.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +110.5 KB
Content
1753258821265-310.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +189.0 KB
Content