... ... @@ -394,6 +394,61 @@
394 394  (% style="color:blue" %)**AT+SERVADDR=67.207.76.90,4445**
395 395  
396 396  
397 +== 3.5 Telemetry2U ==
398 +
399 +
400 +=== Configuring the Dragino NB Sensor Settings ===
401 +
402 +
403 +(% style="color:blue" %)**AT+SERVADDR=telemetry2u.com,4483**(%%) – Sets the server address and port for sending data to the Telemetry2U IoT platform.
404 +
405 +(% style="color:blue" %)**AT+APN=simbase**(%%) – Sets the APN required for LTE-M connectivity using a Simbase global SIM card.
406 +
407 +(% style="color:blue" %)**ATZ**(%%) – Reboots the device to apply the changes. It won’t transmit to Telemetry2U until added and configured on the platform.
408 +
409 +(% style="color:blue" %)**AT+CFG**(%%) – Displays the current configuration. Take note of the 8-byte (HEX) **DEUI**, which you’ll need in the next setup step.
410 +
411 +And that’s it! These simple steps will get your device up and running on our Telemetry2U servers in no time.
412 +
413 +
414 +**Step 1: Log in Telemetry2U**
415 +
416 +
417 +Users can register a Telemetry2U account for their first use
418 +
419 +**[[https:~~/~~/telemetry2u.com/Identity/Account/Register>>https://telemetry2u.com/Identity/Account/Register]]**
420 +
421 +
422 +**Step 2: Add the device**
423 +
424 +[[image:1753258256594-216.png||height="686" width="1382"]]
425 +
426 +
427 +**1. Select Network provide:**Users need to select Telemetry2U NB-IoT over UDP in order to connect to the platform
428 +
429 +**2. Select device type:**Select the template you need to use
430 +
431 +**3. Fill in Description:**Fill in the unique description
432 +
433 +4. **Fill in IMEI:**The IMEI corresponds to the IME of the device
434 +
435 +After completion, click "**Greate**"
436 +
437 +[[image:1753258480811-335.png||height="789" width="1380"]]
438 +
439 +
440 +**Step 3: Check the data**
441 +
442 +
443 +[[image:1753258821265-310.png||height="681" width="1365"]]
444 +
445 +
446 +
447 +For more information, please refer to the user manual on the Telemetry2U official website:
448 +
449 +**[[https:~~/~~/telemetry2u.com/Documentation/dragino-lte-m-nb-iot-sensors-iot-platform-integration>>https://telemetry2u.com/Documentation/dragino-lte-m-nb-iot-sensors-iot-platform-integration]]**
450 +
451 +
397 397  == 3.5 Node-Red (via MQTT) ==
398 398  
399 399  === 3.5.1 Configure [[Node-Red>>http://wiki.dragino.com/xwiki/bin/view/Main/Node-RED/]] ===
... ... @@ -1049,27 +1049,22 @@
1049 1049  
1050 1050  //Example~:// For the S31-NB's uplink interval modification (AT+TDC=900):
1051 1051  
1052 -* HEX format: (% style="color:blue" %)**01000384**(%%)  ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds.
1053 -* JSON format: (% style="color:blue" %)**{AT+TDC=900}       **(%%)~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}.
1107 +Downlink command:  (% style="color:blue" %)**01000384**(%%)  ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds.
1054 1054  
1055 -(% style="color:red" %)**Note:**
1056 -
1057 -(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.**
1058 -
1059 -(% style="color:red" %)**2. Devices designed with downlink commands can utilize different downlink formats (e.g., JSON or HEX) for configuration. However, regardless of the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.**
1060 -
1061 -(% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.**
1062 -
1063 1063  [[image:1750035004731-376.png||height="276" width="557"]]
1064 1064  
1065 1065  
1112 +==== **2. JSON-format ** ====
1066 1066  
1114 +===== **2. 1 JSON format template.** =====
1067 1067  
1068 -**Template for Batch Configuration:**
1116 +All -NB nodes support downlink configuration modification using (% style="color:blue" %)**JSON format templates.**
1069 1069  
1070 -We can also use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device.
1071 -Template:
1118 +We can use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device.
1119 +Template.
1072 1072  
1121 +Take the template of D2x-NB as an example:
1122 +
1073 1073  {
1074 1074  "AT+SERVADDR":"119.91.62.30,1882",
1075 1075  "AT+CLIENT":"JwcXKjQBNhQ2JykDDAA5Ahs",
... ... @@ -1093,6 +1093,11 @@
1093 1093  "AT+TEMPALARM3":"0"
1094 1094  }
1095 1095  
1146 +Explanations of two special commands in the template: AT+TR (set the detection interval: 0 ~~ 255 minutes) and AT+NOUD (set the number of groups) correspond to parameters in AT+CLOCKLOG.
1147 +
1148 +[[image:1751538862245-924.png]]
1149 +
1150 +
1096 1096  **Instructions for Using the Template:**
1097 1097  
1098 1098  1. Modify the parameters for each AT command in the template as needed.
... ... @@ -1105,6 +1105,23 @@
1105 1105  
1106 1106  
1107 1107  
1163 +===== **2.2 Support sending json format commands separately** =====
1164 +
1165 +Some models of nodes support sending json format commands separately:(% style="color:blue" %)**RS485-NB, LDS25-NB, CS01-NB, SDI-12-NB, SW3L-NB, WL03A-NB, PS-NB, LTC2-NB.**
1166 +
1167 +//Example~:// For the PS-NB's uplink interval modification (AT+TDC=900):
1168 +
1169 +Downlink command:  (% style="color:blue" %)**{AT+TDC=900}**(%%)**       **~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}.
1170 +
1171 +(% style="color:red" %)**Note:**
1172 +
1173 +(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.**
1174 +
1175 +(% style="color:red" %)**2. Devices designed with downlink commands can utilize different downlink formats (e.g., JSON or HEX) for configuration. However, regardless of the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.**
1176 +
1177 +(% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.**
1178 +
1179 +
1108 1108  == (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.6 How to get the debug log for further analyze?(%%) ==
1109 1109  
1110 1110  
1751538862245-924.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +114.7 KB
Content
1753258256594-216.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +153.1 KB
Content
1753258480811-335.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +110.5 KB
Content
1753258821265-310.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Kilight
Size
... ... @@ -1,0 +1,1 @@
1 +189.0 KB
Content