Content
... ... @@ -1043,12 +1043,14 @@
1043 1043  (% data-sider-select-id="90b80f1a-e924-4c8a-afc5-4429e019a657" %)
1044 1044  === **MQTT Protocol:** ===
1045 1045  
1046 -Supports both **JSON-format** and **HEX-format** downlink commands (corresponding to AT commands).
1046 +==== **1. HEX-format** ====
1047 1047  
1048 +Supports **HEX-format** downlink commands (corresponding to AT commands).
1049 +
1048 1048  //Example~:// For the S31-NB's uplink interval modification (AT+TDC=900):
1049 1049  
1050 1050  * HEX format: (% style="color:blue" %)**01000384**(%%)  ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds.
1051 -* JSON format: (% style="color:blue" %)**{AT+TDC=900}  **(%%)~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}.
1053 +* JSON format: (% style="color:blue" %)**{AT+TDC=900}       **(%%)~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}.
1052 1052  
1053 1053  (% style="color:red" %)**Note:**
1054 1054  
... ... @@ -1061,6 +1061,8 @@
1061 1061  [[image:1750035004731-376.png||height="276" width="557"]]
1062 1062  
1063 1063  
1066 +
1067 +
1064 1064  **Template for Batch Configuration:**
1065 1065  
1066 1066  We can also use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device.
... ... @@ -1161,26 +1161,26 @@
1161 1161  
1162 1162  We are now dividing the **old firmware**(without FDR1 function) with the **new firmware**(with FDR1 function) by whether it contains FDR1 functionality. Please refer to the table:
1163 1163  
1164 -(% border="1" style="background-color:#f2f2f2; width:814px" %)
1165 -|(% style="background-color:#4f81bd; color:white; width:210px" %)**General Model**|(% style="background-color:#4f81bd; color:white; width:313px" %)(((
1168 +(% border="1" style="background-color:#f2f2f2; width:912px" %)
1169 +|(% style="background-color:#4f81bd; color:white; width:306px" %)**General Model**|(% style="background-color:#4f81bd; color:white; width:311px" %)(((
1166 1166  **Firmware version (without FDR1 function)**
1167 -)))|(% style="background-color:#4f81bd; color:white; width:286px" %)(((
1171 +)))|(% style="background-color:#4f81bd; color:white; width:289px" %)(((
1168 1168  **Firmware version (with FDR1 function)**
1169 1169  )))
1170 -|(% style="width:210px" %)(((
1174 +|(% style="width:306px" %)(((
1171 1171  CPL03-NB, S31-NB, SN50V3-NB, TS01-NB, D20-NB, DS03A-NB, DDS04-NB, DDS45-NB, DDS20-NB, DDS75-NB, LDS12-NB, LDS40-NB, LMS01-NB, MDS120-NB,  MDS200-NB, SE01-NB, SPH01-NB;
1172 -)))|(% style="width:313px" %)Before V1.2.1|(% style="width:286px" %)After V1.2.1 (including V1.2.1)
1173 -|(% style="width:210px" %)(((
1176 +)))|(% style="width:311px" %)Before V1.2.1|(% style="width:289px" %)After V1.2.1 (including V1.2.1)
1177 +|(% style="width:306px" %)(((
1174 1174  WL03A-NB, SDI-12-NB;
1175 -)))|(% style="width:313px" %)Before V1.0.2|(% style="width:286px" %)(((
1179 +)))|(% style="width:311px" %)Before V1.0.2|(% style="width:289px" %)(((
1176 1176  After V1.0.8 (including V1.0.2)
1177 1177  )))
1178 -|(% style="width:210px" %)(((
1182 +|(% style="width:306px" %)(((
1179 1179  SW3L-NB, PS-NB;
1180 -)))|(% style="width:313px" %)Before V1.0.5|(% style="width:286px" %)(((
1184 +)))|(% style="width:311px" %)Before V1.0.5|(% style="width:289px" %)(((
1181 1181  After V1.0.5 (including V1.0.5)
1182 1182  )))
1183 -|(% style="width:210px" %)RS485-NB|(% style="width:313px" %)Before V1.0.8|(% style="width:286px" %)After V1.0.8 (including V1.0.8)
1187 +|(% style="width:306px" %)RS485-NB|(% style="width:311px" %)Before V1.0.8|(% style="width:289px" %)After V1.0.8 (including V1.0.8)
1184 1184  
1185 1185  === UART connection and firmware update methods ===
1186 1186  
... ... @@ -1238,4 +1238,11 @@
1238 1238  
1239 1239  
1240 1240  
1245 +== 6.8 ==
1246 +
1247 +
1248 +
1249 +
1250 +
1251 +