Last modified by Mengting Qiu on 2025/07/17 10:51
From version 229.9
edited by Mengting Qiu
on 2025/06/16 09:14
on 2025/06/16 09:14
Change comment:
There is no comment for this version
To version 229.18
edited by Mengting Qiu
on 2025/06/16 09:27
on 2025/06/16 09:27
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1047,15 +1047,23 @@ 1047 1047 1048 1048 //Example~:// For the S31-NB's uplink interval modification (AT+TDC=900): 1049 1049 1050 -* HEX format: (% style="color:blue" %)**01000384**(%%) ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds. 1051 -* JSON format: (% style="color:blue" %)**0 1{AT**1050 +* HEX format: (% style="color:blue" %)**01000384**(%%) ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds. 1051 +* JSON format: (% style="color:blue" %)**{AT+TDC=900} **(%%)~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}. 1052 1052 1053 +(% style="color:red" %)**Note:** 1053 1053 1055 +(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.** 1054 1054 1055 -Json :1057 +(% style="color:red" %)**2. Devices designed with downlink commands can utilize different downlink formats (e.g., JSON or HEX) for configuration. However, regardless of the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.** 1056 1056 1057 -The Json format in MQTT mode needs to be configured with all commands. 1058 -If you have configurations that need to be changed, please change them in the template below. 1059 +(% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.** 1060 + 1061 +[[image:1750035004731-376.png||height="276" width="557"]] 1062 + 1063 + 1064 +**Template for Batch Configuration:** 1065 + 1066 +We can also use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device. 1059 1059 Template: 1060 1060 1061 1061 { ... ... @@ -1081,25 +1081,19 @@ 1081 1081 "AT+TEMPALARM3":"0" 1082 1082 } 1083 1083 1084 - Hex:1092 +**Instructions for Using the Template:** 1085 1085 1086 -MQTT's hex format. Since many commands need to support strings, only a few commands are supported. 1094 +1. Modify the parameters for each AT command in the template as needed. 1095 +1. Send the entire template in one downlink command. 1087 1087 1088 -The supported commands are consistent with LoRaWAN's hex commands. 1089 -Please refer to the following link to obtain the hex format: 1090 - 1091 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1092 - 1093 - 1094 1094 (% style="color:red" %)**Note:** 1095 1095 1096 - (% style="color:red" %)**1. Only when the correctand valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.**1099 +**Note:** 1097 1097 1098 -(% style="color:red" %)**2. Devices designed with downlink commands can utilize different downlink formats (e.g., JSON or HEX) for configuration. However, regardless of the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.** 1101 +* The template may vary depending on the device model. 1102 +* Currently, each specific template is being updated and tested. If you need a template for your specific device, please contact Dragino Technical Support at support@dragino.com to request the latest downlink template. 1099 1099 1100 -(% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.** 1101 1101 1102 -[[image:1750035004731-376.png||height="276" width="557"]] 1103 1103 1104 1104 1105 1105 == (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.6 How to get the debug log for further analyze?(%%) ==