... ... @@ -1047,15 +1047,23 @@
1047 1047  
1048 1048  //Example~:// For the S31-NB's uplink interval modification (AT+TDC=900):
1049 1049  
1050 -* HEX format: (% style="color:blue" %)**01000384**(%%)  ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds.
1051 -* JSON format: (% style="color:blue" %)**01**
1050 +* HEX format: (% style="color:blue" %)**01000384**(%%)  ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds.
1051 +* JSON format: (% style="color:blue" %)**{AT+TDC=900}  **(%%)~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}.
1052 1052  
1053 +(% style="color:red" %)**Note:**
1053 1053  
1055 +(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.**
1054 1054  
1055 -Json
1057 +(% style="color:red" %)**2. Devices designed with downlink commands can utilize different downlink formats (e.g., JSON or HEX) for configuration. However, regardless of the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.**
1056 1056  
1057 -The Json format in MQTT mode needs to be configured with all commands.
1058 -If you have configurations that need to be changed, please change them in the template below.
1059 +(% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.**
1060 +
1061 +[[image:1750035004731-376.png||height="276" width="557"]]
1062 +
1063 +
1064 +**Template for Batch Configuration:**
1065 +
1066 +We can also use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device.
1059 1059  Template:
1060 1060  
1061 1061  {
... ... @@ -1081,27 +1081,19 @@
1081 1081  "AT+TEMPALARM3":"0"
1082 1082  }
1083 1083  
1084 -Hex:
1092 +**Instructions for Using the Template:**
1085 1085  
1086 -MQTT's hex format. Since many commands need to support strings, only a few commands are supported.
1094 +1. Modify the parameters for each AT command in the template as needed.
1095 +1. Send the entire template in one downlink command.
1087 1087  
1088 -The supported commands are consistent with LoRaWAN's hex commands.
1089 -Please refer to the following link to obtain the hex format:
1097 +**Note:**
1090 1090  
1091 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1099 +* The template may vary depending on the device model.
1100 +* If you need a template for your specific device, please contact **Dragino Technical Support** at [[support@dragino.com>>url:https://mailto:support@dragino.com/]] to request the latest downlink template.
1092 1092  
1093 1093  
1094 -(% style="color:red" %)**Note:**
1095 1095  
1096 -(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.**
1097 1097  
1098 -(% style="color:red" %)**2. Devices designed with downlink commands can utilize different downlink formats (e.g., JSON or HEX) for configuration. However, regardless of the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.**
1099 -
1100 -(% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.**
1101 -
1102 -[[image:1750035004731-376.png||height="276" width="557"]]
1103 -
1104 -
1105 1105  == (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.6 How to get the debug log for further analyze?(%%) ==