... ... @@ -1047,11 +1047,23 @@
1047 1047  
1048 1048  //Example~:// For the S31-NB's uplink interval modification (AT+TDC=900):
1049 1049  
1050 +* HEX format: (% style="color:blue" %)**01000384**(%%)  ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds.
1051 +* JSON format: (% style="color:blue" %)**{AT+TDC=900}  **(%%)~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}.
1050 1050  
1051 -Json:
1053 +(% style="color:red" %)**Note:**
1052 1052  
1053 -The Json format in MQTT mode needs to be configured with all commands.
1054 -If you have configurations that need to be changed, please change them in the template below.
1055 +(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.**
1056 +
1057 +(% style="color:red" %)**2. Devices designed with downlink commands can utilize different downlink formats (e.g., JSON or HEX) for configuration. However, regardless of the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.**
1058 +
1059 +(% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.**
1060 +
1061 +[[image:1750035004731-376.png||height="276" width="557"]]
1062 +
1063 +
1064 +**Template for Batch Configuration:**
1065 +
1066 +We can also use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device.
1055 1055  Template:
1056 1056  
1057 1057  {
... ... @@ -1077,25 +1077,20 @@
1077 1077  "AT+TEMPALARM3":"0"
1078 1078  }
1079 1079  
1080 -Hex:
1092 +**Instructions for Using the Template:**
1081 1081  
1082 -MQTT's hex format. Since many commands need to support strings, only a few commands are supported.
1094 +1. Modify the parameters for each AT command in the template as needed.
1095 +1. Send the entire template in one downlink command.
1083 1083  
1084 -The supported commands are consistent with LoRaWAN's hex commands.
1085 -Please refer to the following link to obtain the hex format:
1086 -
1087 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1088 -
1089 -
1090 1090  (% style="color:red" %)**Note:**
1091 1091  
1092 -(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.**
1099 +**Note:**
1093 1093  
1094 -(% style="color:red" %)**2. Devices designed with downlink commands can utilize different downlink formats (e.g., JSON or HEX) for configuration. However, regardless of the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.**
1101 +* The template may vary depending on the device model.
1102 +* Currently, each specific template is being updated and tested.
1103 +* If you need a template for your specific device, please contact **Dragino Technical Support** at [[support@dragino.com>>url:https://mailto:support@dragino.com/]] to request the latest downlink template.
1095 1095  
1096 -(% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.**
1097 1097  
1098 -[[image:1750035004731-376.png||height="276" width="557"]]
1099 1099  
1100 1100  
1101 1101  == (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.6 How to get the debug log for further analyze?(%%) ==