Last modified by Mengting Qiu on 2025/07/17 10:51

From version 229.2
edited by Mengting Qiu
on 2025/06/16 09:07
Change comment: There is no comment for this version
To version 229.16
edited by Mengting Qiu
on 2025/06/16 09:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1035,19 +1035,28 @@
1035 1035  Only supports valid **HEX-format downlink commands** corresponding to AT command.
1036 1036  
1037 1037  Take the AT+TDC command of S31-NB as an example, that is, only the valid HEX format downstream command corresponding to the AT+TDC command can be used:
1038 -
1038 +Downward format: (% style="color:blue" %)**01000384**(%%)  ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds.
1039 1039  
1040 1040  [[image:1750035991532-434.png||height="237" width="495"]]
1041 1041  
1042 1042  
1043 1043  (% data-sider-select-id="90b80f1a-e924-4c8a-afc5-4429e019a657" %)
1044 -=== MQTT: ===
1044 +=== **MQTT Protocol:** ===
1045 1045  
1046 +Supports both **JSON-format** and **HEX-format** downlink commands (corresponding to AT commands).
1046 1046  
1047 -Json
1048 +//Example~:// For the S31-NB's uplink interval modification (AT+TDC=900):
1048 1048  
1049 -The Json format in MQTT mode needs to be configured with all commands.
1050 -If you have configurations that need to be changed, please change them in the template below.
1050 +* HEX format: (% style="color:blue" %)**01000384**(%%)  ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds.
1051 +* JSON format: (% style="color:blue" %)**{AT+TDC=900}  **(%%)~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}.
1052 +
1053 +
1054 +
1055 +**Template for Batch Configuration:**
1056 +
1057 +We can also use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device.
1058 +
1059 +
1051 1051  Template:
1052 1052  
1053 1053  {
... ... @@ -1073,16 +1073,13 @@
1073 1073  "AT+TEMPALARM3":"0"
1074 1074  }
1075 1075  
1076 -Hex:
1085 +**Instructions for Using the Template:**
1077 1077  
1078 -MQTT's hex format. Since many commands need to support strings, only a few commands are supported.
1087 +1. Modify the parameters for each AT command in the template as needed.
1088 +1. Send the entire template in one downlink command.
1079 1079  
1080 -The supported commands are consistent with LoRaWAN's hex commands.
1081 -Please refer to the following link to obtain the hex format:
1082 1082  
1083 -[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1084 1084  
1085 -
1086 1086  (% style="color:red" %)**Note:**
1087 1087  
1088 1088  (% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.**