Last modified by Mengting Qiu on 2025/07/17 10:51
From version 229.17
edited by Mengting Qiu
on 2025/06/16 09:26
on 2025/06/16 09:26
Change comment:
There is no comment for this version
To version 229.8
edited by Mengting Qiu
on 2025/06/16 09:14
on 2025/06/16 09:14
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1047,23 +1047,15 @@ 1047 1047 1048 1048 //Example~:// For the S31-NB's uplink interval modification (AT+TDC=900): 1049 1049 1050 -* HEX format: (% style="color:blue" %)**01000384**(%%) 1051 -* JSON format: (% style="color:blue" %)** {AT+TDC=900}**(%%)~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}.1050 +* HEX format: (% style="color:blue" %)**01000384**(%%) ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds. 1051 +* JSON format: (% style="color:blue" %)**01** 1052 1052 1053 -(% style="color:red" %)**Note:** 1054 1054 1055 -(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.** 1056 1056 1057 - (% style="color:red" %)**2. Devices designed with downlink commands can utilize different downlink formats (e.g.,JSON or HEX) for configuration. However, regardlessof the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.**1055 +Json: 1058 1058 1059 -(% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.** 1060 - 1061 -[[image:1750035004731-376.png||height="276" width="557"]] 1062 - 1063 - 1064 -**Template for Batch Configuration:** 1065 - 1066 -We can also use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device. 1057 +The Json format in MQTT mode needs to be configured with all commands. 1058 +If you have configurations that need to be changed, please change them in the template below. 1067 1067 Template: 1068 1068 1069 1069 { ... ... @@ -1089,19 +1089,27 @@ 1089 1089 "AT+TEMPALARM3":"0" 1090 1090 } 1091 1091 1092 - **Instructions for Using theTemplate:**1084 +Hex: 1093 1093 1094 -1. Modify the parameters for each AT command in the template as needed. 1095 -1. Send the entire template in one downlink command. 1086 +MQTT's hex format. Since many commands need to support strings, only a few commands are supported. 1096 1096 1097 -**Note:** 1088 +The supported commands are consistent with LoRaWAN's hex commands. 1089 +Please refer to the following link to obtain the hex format: 1098 1098 1099 -* The template may vary depending on the device model. 1100 -* If you need a template for your specific device, please contact **Dragino Technical Support** at [[support@dragino.com>>url:https://mailto:support@dragino.com/]] to request the latest downlink template. 1091 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1101 1101 1102 1102 1094 +(% style="color:red" %)**Note:** 1103 1103 1096 +(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.** 1104 1104 1098 +(% style="color:red" %)**2. Devices designed with downlink commands can utilize different downlink formats (e.g., JSON or HEX) for configuration. However, regardless of the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.** 1099 + 1100 +(% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.** 1101 + 1102 +[[image:1750035004731-376.png||height="276" width="557"]] 1103 + 1104 + 1105 1105 == (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.6 How to get the debug log for further analyze?(%%) == 1106 1106 1107 1107