Last modified by Mengting Qiu on 2025/07/17 10:51
From version 229.16
edited by Mengting Qiu
on 2025/06/16 09:25
on 2025/06/16 09:25
Change comment:
There is no comment for this version
To version 229.2
edited by Mengting Qiu
on 2025/06/16 09:07
on 2025/06/16 09:07
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1035,28 +1035,19 @@ 1035 1035 Only supports valid **HEX-format downlink commands** corresponding to AT command. 1036 1036 1037 1037 Take the AT+TDC command of S31-NB as an example, that is, only the valid HEX format downstream command corresponding to the AT+TDC command can be used: 1038 - Downwardformat: (% style="color:blue" %)**01000384**(%%) ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds.1038 + 1039 1039 1040 1040 [[image:1750035991532-434.png||height="237" width="495"]] 1041 1041 1042 1042 1043 1043 (% data-sider-select-id="90b80f1a-e924-4c8a-afc5-4429e019a657" %) 1044 -=== **MQTTProtocol:**===1044 +=== MQTT: === 1045 1045 1046 -Supports both **JSON-format** and **HEX-format** downlink commands (corresponding to AT commands). 1047 1047 1048 - //Example~:// For the S31-NB'suplink interval modification(AT+TDC=900):1047 +Json: 1049 1049 1050 -* HEX format: (% style="color:blue" %)**01000384**(%%) ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds. 1051 -* JSON format: (% style="color:blue" %)**{AT+TDC=900} **(%%)~/~/ The correct format is (% style="color:blue" %)**{AT Command}**(%%). No extra characters other than valid AT commands can be added within {}. 1052 - 1053 - 1054 - 1055 -**Template for Batch Configuration:** 1056 - 1057 -We can also use templates to configure multiple commands AT once. Users only need to modify the parameters of the required AT commands in the correct template for each device. 1058 - 1059 - 1049 +The Json format in MQTT mode needs to be configured with all commands. 1050 +If you have configurations that need to be changed, please change them in the template below. 1060 1060 Template: 1061 1061 1062 1062 { ... ... @@ -1082,13 +1082,16 @@ 1082 1082 "AT+TEMPALARM3":"0" 1083 1083 } 1084 1084 1085 - **Instructions for Using theTemplate:**1076 +Hex: 1086 1086 1087 -1. Modify the parameters for each AT command in the template as needed. 1088 -1. Send the entire template in one downlink command. 1078 +MQTT's hex format. Since many commands need to support strings, only a few commands are supported. 1089 1089 1080 +The supported commands are consistent with LoRaWAN's hex commands. 1081 +Please refer to the following link to obtain the hex format: 1090 1090 1083 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1091 1091 1085 + 1092 1092 (% style="color:red" %)**Note:** 1093 1093 1094 1094 (% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.**