Last modified by Mengting Qiu on 2025/07/03 18:55

From version 228.4
edited by Mengting Qiu
on 2025/06/16 08:57
Change comment: There is no comment for this version
To version 229.4
edited by Mengting Qiu
on 2025/06/16 09:09
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1028,21 +1028,18 @@
1028 1028  
1029 1029  
1030 1030  Firstly, it is recommended that users upgrade the firmware of the -NB node to the latest version, as the processing method for downlink commands varies depending on the firmware version. Below, we will introduce the latest downlink command format.
1031 -(% style="color:red" %)**Note:**
1032 1032  
1033 -(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.**
1032 +(% data-sider-select-id="bb6e9353-0c3f-473c-938d-4b416c9a03e6" %)
1033 +=== **UDP Protocol:** ===
1034 1034  
1035 -(% style="color:red" %)**2. **
1035 +Only supports valid **HEX-format downlink commands** corresponding to AT command.
1036 1036  
1037 +Take the AT+TDC command of S31-NB as an example, that is, only the valid HEX format downstream command corresponding to the AT+TDC command can be used:
1038 +Downward format: 01000384  ~/~/ There are no Spaces. 0x0384(H)=900(D), that is, modify TDC to 900 seconds
1037 1037  
1038 -[[image:1750035004731-376.png]]
1040 +[[image:1750035991532-434.png||height="237" width="495"]]
1039 1039  
1040 1040  
1041 -(% data-sider-select-id="bb6e9353-0c3f-473c-938d-4b416c9a03e6" %)
1042 -=== **UDP Protocol:** ===
1043 -
1044 -Only supports valid **HEX-format downlink commands** corresponding to AT command
1045 -
1046 1046  (% data-sider-select-id="90b80f1a-e924-4c8a-afc5-4429e019a657" %)
1047 1047  === MQTT: ===
1048 1048  
... ... @@ -1086,6 +1086,17 @@
1086 1086  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1087 1087  
1088 1088  
1086 +(% style="color:red" %)**Note:**
1087 +
1088 +(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.**
1089 +
1090 +(% style="color:red" %)**2. Devices designed with downlink commands can utilize different downlink formats (e.g., JSON or HEX) for configuration. However, regardless of the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.**
1091 +
1092 +(% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.**
1093 +
1094 +[[image:1750035004731-376.png||height="276" width="557"]]
1095 +
1096 +
1089 1089  == (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.6 How to get the debug log for further analyze?(%%) ==
1090 1090  
1091 1091  
1750035991532-434.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.ting
Size
... ... @@ -1,0 +1,1 @@
1 +54.4 KB
Content