Last modified by Mengting Qiu on 2025/07/03 18:55

From version 228.4
edited by Mengting Qiu
on 2025/06/16 08:57
Change comment: There is no comment for this version
To version 228.7
edited by Mengting Qiu
on 2025/06/16 09:05
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1028,20 +1028,11 @@
1028 1028  
1029 1029  
1030 1030  Firstly, it is recommended that users upgrade the firmware of the -NB node to the latest version, as the processing method for downlink commands varies depending on the firmware version. Below, we will introduce the latest downlink command format.
1031 -(% style="color:red" %)**Note:**
1032 1032  
1033 -(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.**
1034 -
1035 -(% style="color:red" %)**2. **
1036 -
1037 -
1038 -[[image:1750035004731-376.png]]
1039 -
1040 -
1041 1041  (% data-sider-select-id="bb6e9353-0c3f-473c-938d-4b416c9a03e6" %)
1042 1042  === **UDP Protocol:** ===
1043 1043  
1044 -Only supports valid **HEX-format downlink commands** corresponding to AT command
1035 +Only supports valid **HEX-format downlink commands** corresponding to AT command.
1045 1045  
1046 1046  (% data-sider-select-id="90b80f1a-e924-4c8a-afc5-4429e019a657" %)
1047 1047  === MQTT: ===
... ... @@ -1086,6 +1086,17 @@
1086 1086  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]]
1087 1087  
1088 1088  
1080 +(% style="color:red" %)**Note:**
1081 +
1082 +(% style="color:red" %)**1. Only when the correct and valid download command is used and the format is correct can the device be configured through the download command. Invalid download content cannot be processed by the device and will be automatically restarted.**
1083 +
1084 +(% style="color:red" %)**2. Devices designed with downlink commands can utilize different downlink formats (e.g., JSON or HEX) for configuration. However, regardless of the format, the functionality is strictly limited to the downlink command specifications described in the user manual's AT command explanation.**
1085 +
1086 +(% style="color:red" %)**For example, the HEX-format downlink command corresponding to AT+TDC can only be used to configure TDC and cannot be used for queries. There is no HEX-format downlink command equivalent to AT+TDC=? , so querying TDC via downlink is not supported.**
1087 +
1088 +[[image:1750035004731-376.png||height="276" width="557"]]
1089 +
1090 +
1089 1089  == (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.6 How to get the debug log for further analyze?(%%) ==
1090 1090  