Last modified by Mengting Qiu on 2025/07/03 18:55
From version 227.1
edited by Mengting Qiu
on 2025/06/13 19:43
on 2025/06/13 19:43
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Xiaoling - Content
-
... ... @@ -602,17 +602,26 @@ 602 602 Note:The port for the COAP protocol has been fixed to 5683 603 603 604 604 605 -* AT+UR I1=11,(% style="color:red" %)**character length**(%%),"Needs to be consistent with the CoAP endpoint URL in the platform",605 +* AT+URL1=11,(% style="color:red" %)**character length**(%%),"Needs to be consistent with the CoAP endpoint URL in the platform" 606 606 607 - -NB/NSproductsusethe(% style="color:red" %)**BC660K**(%%)module,only need to configure(% style="color:red" %)**only one URL**(%%) command.607 +If the module used is (% style="color:red" %)**BC660K, only one **(%%)URL directive needs to be configured, 608 608 609 609 e.g. 610 610 611 -* AT+UR I1=11,38, "i/faaaa241f-af4a-b780-4468-c671bb574858"611 +* AT+URL1=11,38, "i/faaaa241f-af4a-b780-4468-c671bb574858" 612 612 613 613 [[image:image-20240729172415-13.png||height="401" width="694"]] 614 614 615 +If you are using a (% style="color:red" %)**BG95-M2**(%%) module, you need to configure (% style="color:red" %)**TWO**(%%) URL commands, 615 615 617 +e.g. 618 + 619 +* AT+URL1=11, "i" 620 +* AT+URL2=11,"faaaa241f-af4a-b780-4468-c671bb574858" 621 + 622 +[[image:image-20240729172500-14.png||height="403" width="700"]] 623 + 624 + 616 616 == 3.8 [[Tago.io>>url:https://admin.tago.io/]] (via MQTT) == 617 617 618 618 === 3.8.1 Create device & Get Credentials === ... ... @@ -845,7 +845,7 @@ 845 845 * (% style="color:#037691" %)**AT+CLIENT=NULL** 846 846 * (% style="color:#037691" %)**AT+UNAME=NULL** 847 847 * (% style="color:#037691" %)**AT+PWD=NULL** 848 -* (% style="color:#037691" %)**AT+TLSMOD=1, 2**857 +* (% style="color:#037691" %)**AT+TLSMOD=1,0** 849 849 850 850 Test Uplink by click the button for 1~~3 seconds, the MQTT integration in ThingsEye allows you to view the data upstream from the device: 851 851 ... ... @@ -1024,16 +1024,20 @@ 1024 1024 [[image:image-20240226111928-1.png]] 1025 1025 1026 1026 1027 -== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.5 (%%)What is the Downlink CommandFormatforNBDevices? ==1036 +== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.5 What is the Downlink Command by the NB device?(%%) == 1028 1028 1029 1029 1030 -Firstly, it is recommended that users upgrade the firmware of the -NB node to the latest version, as the processing method for downlink commands varies depending on the firmware version. Below, we will introduce the latest downlink command format. 1031 - 1032 1032 (% data-sider-select-id="bb6e9353-0c3f-473c-938d-4b416c9a03e6" %) 1033 -=== **UDPProtocol:**===1040 +=== UDP: === 1034 1034 1035 -Only supports valid **HEX-format downlink commands** corresponding to AT command 1036 1036 1043 +(% data-sider-select-id="14a4790e-7faa-4508-a4dd-7605a53f1cb3" %) 1044 +Its downlink command is the same as the AT command, but brackets are required. 1045 +Example: 1046 + 1047 +{AT+TDC=300} 1048 + 1049 + 1037 1037 (% data-sider-select-id="90b80f1a-e924-4c8a-afc5-4429e019a657" %) 1038 1038 === MQTT: === 1039 1039 ... ... @@ -1077,44 +1077,16 @@ 1077 1077 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 1078 1078 1079 1079 1080 -== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.6 How to getthedebuglogfor further analyze?(%%) ==1093 +== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.6 How to obtain device logs?(%%) == 1081 1081 1082 1082 1083 - Ifuseris not able to solve the connection issue, user can use belowmethodandget the device log and send to Dragino (Support@dragino.cc) for further analyze.1096 +* **AT Command: AT** **+GETLOG** 1084 1084 1098 +This command can be used to query upstream logs of data packets. 1085 1085 1086 -(% class="lead" %) 1087 -Step1: Use Mobile Phone to connect device 1100 +[[image:image-20240701114700-1.png]] 1088 1088 1089 -See this link: **[[how to connect via Mobile Phone:>>https://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/#H3.1UseDraginoDeviceTooltoconfigureorupgradefirmware]]** 1090 1090 1091 - 1092 -(% class="lead" %) 1093 -Step2: Get Log by different commands. 1094 - 1095 -Use below three method to generate logs. 1096 - 1097 -* **AT+CFG ~-~-> Command to show the current configuration** 1098 -* **AT** **+GETLOG ~-~-> Command to get the previous upstream log** 1099 -* **press the toggle button for 1 ~~2 seconds ~-~-> Trigger a uplink** 1100 - 1101 -Above are the output example for about three action: 1102 - 1103 -[[image:image-20250121235119-1.png||height="493" width="455"]] 1104 - 1105 -[[image:image-20240207002129-2.png]] 1106 - 1107 - 1108 -(% class="lead" %) 1109 -Step3: Export Log 1110 - 1111 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/BLE%20Bluetooth%20Remote%20Configure/WebHome/image-20241230155425-16.png?width=330&height=85&rev=1.1||alt="image-20241230155425-16.png" height="85" width="330"]] 1112 - 1113 -select the log you want to export, then click the share icon on the far right to enter the document that comes with your phone and choose to export it. 1114 - 1115 -[[image:https://wiki.dragino.com/xwiki/bin/download/Main/BLE%20Bluetooth%20Remote%20Configure/WebHome/image-20241230155528-17.png?width=327&height=324&rev=1.1||alt="image-20241230155528-17.png" height="324" width="327"]] 1116 - 1117 - 1118 1118 == 6.7 How to find the AT Command Password if lost? == 1119 1119 1120 1120 ... ... @@ -1132,6 +1132,7 @@ 1132 1132 * (% style="color:#037691; font-weight:bold" %)**AT+FDR**(%%)** **~/~/ Reset Parameters to Factory Default. 1133 1133 * (% style="color:#037691; font-weight:bold" %)**AT+FDR1**(%%)** **~/~/ Reset parameters to factory default values except for passwords.(new) 1134 1134 1120 + 1135 1135 === Version Confirmation === 1136 1136 1137 1137 ... ... @@ -1162,6 +1162,7 @@ 1162 1162 ))) 1163 1163 |(% style="width:210px" %)RS485-NB|(% style="width:150px" %)Before V1.0.8|(% style="width:150px" %)After V1.0.8 (including V1.0.8) 1164 1164 1151 + 1165 1165 === UART connection and firmware update methods === 1166 1166 1167 1167
- image-20250121235119-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -145.4 KB - Content