<
From version < 183.1 >
edited by Mengting Qiu
on 2024/08/28 14:44
To version < 181.1 >
edited by Mengting Qiu
on 2024/08/28 14:37
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -942,7 +942,7 @@
942 942  == 6.7 How to find the AT Command Password if lost? ==
943 943  
944 944  
945 -=== Why can't the password access AT command after upgrade(-NB)? ===
945 +== 6.7.1. Why can't the password access AT command after upgrade(-NB)? ==
946 946  
947 947  
948 948  Because the new version of -NB firmware has updated the factory reset function, users can choose to restore all parameters to factory Settings, or keep the password to restore the rest of the parameters to factory Settings.
... ... @@ -956,8 +956,9 @@
956 956  * (% style="color:#037691; font-weight:bold" %)**AT+FDR**(%%)**       **~/~/ Reset Parameters to Factory Default.
957 957  * (% style="color:#037691; font-weight:bold" %)**AT+FDR1**(%%)**     **~/~/ Reset parameters to factory default values except for passwords.(new)
958 958  
959 -=== Version Confirmation ===
959 +== 6.7.2 Version Confirmation ==
960 960  
961 +
961 961  We are now dividing the **old firmware**(without FDR1 function) with the **new firmware**(with FDR1 function) by whether it contains FDR1 functionality. Please refer to the table:
962 962  
963 963  (% border="1" style="background-color:#f2f2f2; width:510px" %)
... ... @@ -985,9 +985,10 @@
985 985  )))
986 986  |(% style="width:210px" %)RS485-NB|(% style="width:150px" %)Before V1.0.8|(% style="width:150px" %)After V1.0.8 (including V1.0.8)
987 987  
988 -=== UART connection and firmware update methods ===
989 989  
990 +== 6.7.3 UART connection and firmware update methods ==
990 990  
992 +
991 991  Users can query passwords only using the UART interface via the STM32CubeProgrammer.
992 992  
993 993  See **[[UART Connection>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]**.
... ... @@ -995,7 +995,7 @@
995 995  update firmware through UART TTL interface :** [[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART_Access_for_NB_ST_BC660K-GL/#H4.2UpdateFirmware28Assumethedevicealreadyhaveabootloader29]]**.
996 996  
997 997  
998 -=== query the password via STM32CubeProgrammer ===
1000 +== 6.7.4 query the password via STM32CubeProgrammer ==
999 999  
1000 1000  
1001 1001  Users can use the password address to query the password through STM32CubeProgrammer.
... ... @@ -1018,7 +1018,7 @@
1018 1018  
1019 1019  **Procedure for querying the password(new firmware):**
1020 1020  
1021 -Refer to [[the old and new firmware division>>http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#HVersionConfirmation]] above, and run the firmware first after updating the firmware.
1023 +Refer to [[the old and new firmware division>>http://wiki.dragino.com/xwiki/bin/view/Why%20can%27t%20the%20password%20access%20AT%20command%20after%20upgrade%28-NB%29%3F/#H3.A0VersionConfirmation]] above, and run the firmware first after updating the firmware.
1022 1022  
1023 1023  * After the firmware upgrade is complete, switch back to the **FLASH** and reset the node to **run the new firmware once**.
1024 1024  * Then place the switch at the **ISP** and connect to the STM32CubeProgrammer (same as when burning the firmware).
... ... @@ -1029,7 +1029,7 @@
1029 1029  
1030 1030  
1031 1031  
1032 -=== Special case ===
1034 +== 6.7.5. Special case ==
1033 1033  
1034 1034  
1035 1035  If the user has never changed the password manually, the user cannot find the valid password through the above two password addresses. In this case, the valid password is still the original password on the node box label (**AT+PIN**).
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0