Last modified by Mengting Qiu on 2025/03/08 11:33
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.Bei - Content
-
... ... @@ -284,7 +284,6 @@ 284 284 285 285 ==== 3.4.1.1 Create Device ==== 286 286 287 - 288 288 (% style="color:blue" %)**Add Device**(%%) in DataCake. 289 289 290 290 [[image:image-20230808162301-1.png||height="453" width="952"]] ... ... @@ -355,9 +355,9 @@ 355 355 356 356 **Step6: Please add the decoder at the payload decoder of the device configuration.** 357 357 358 -**Decoder location: 357 +**Decoder location:**[[dragino-end-node-decoder/Datacake-Dragino_NB at main · dragino/dragino-end-node-decoder (github.com)>>url:https://github.com/dragino/dragino-end-node-decoder/tree/main/Datacake-Dragino_NB]] 359 359 360 -**Due to version update, please use the following decoder for the new version firmware :**359 +**Due to version update, please use the following decoder for the new version firmware** 361 361 [[dragino-end-node-decoder/Datacake-Dragino_NB_New_Version at main · dragino/dragino-end-node-decoder (github.com)>>url:https://github.com/dragino/dragino-end-node-decoder/tree/main/Datacake-Dragino_NB_New_Version]] 362 362 363 363 [[image:image-20240129172056-7.png||height="457" width="816"]] ... ... @@ -541,6 +541,7 @@ 541 541 [[image:image-20230802112413-43.png||height="407" width="825"]] 542 542 543 543 543 + 544 544 == 3.7 ThingsBoard.Cloud (via COAP) == 545 545 546 546 === 3.7.1 Configure ThingsBoard === ... ... @@ -579,7 +579,6 @@ 579 579 580 580 ==== 3.7.1.3 Add COAP Integration ==== 581 581 582 - 583 583 ==== [[image:image-20240729161543-9.png||height="500" width="1009"]] ==== 584 584 585 585 ... ... @@ -587,7 +587,6 @@ 587 587 588 588 ==== 3.7.2.1 Instruction Description ==== 589 589 590 - 591 591 * AT+PRO=1,0(HEX format uplink) &AT+PRO=1,5(JSON format uplink) 592 592 * AT+SERVADDR=COAP Server Address,5683 593 593 ... ... @@ -722,11 +722,12 @@ 722 722 Users can refer to [[Dragino NB device connection to AWS platform instructions>>http://wiki.dragino.com/xwiki/bin/view/Dragino%20NB%20device%20connection%20to%20AWS%20platform%20instructions/#H1.LogintotheplatformandfindIoTcore]] 723 723 724 724 723 + 724 + 725 725 = 4. MQTT/UDP/TCP downlink = 726 726 727 727 == 4.1 MQTT (via MQTT.fx) == 728 728 729 - 730 730 Configure MQTT connections properly and send downlink commands to configure nodes through the Publish function of MQTT.fx//.// 731 731 732 732 **1.** Configure node MQTT connection (via MQTT.fx): ... ... @@ -767,6 +767,11 @@ 767 767 (% style="color:red" %)**Note: Users can edit the hex command in advance. When the node uplink, directly click the publish button several times to increase the success rate of command configuration.** 768 768 769 769 769 + 770 + 771 + 772 + 773 + 770 770 = 5. FAQ = 771 771 772 772 == 5.1 What is the usage of Multi Sampling and One Uplink? == ... ... @@ -929,9 +929,8 @@ 929 929 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 930 930 931 931 932 -== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.6 How to obtain device logs ?(%%) ==936 +== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.6 How to obtain device logs?(%%) == 933 933 934 - 935 935 * **AT Command: AT** **+GETLOG** 936 936 937 937 This command can be used to query upstream logs of data packets. ... ... @@ -939,108 +939,5 @@ 939 939 [[image:image-20240701114700-1.png]] 940 940 941 941 942 -== 6.7 How to find the AT Command Password if lost? == 943 943 944 - 945 -=== Why can't the password access AT command after upgrade(-NB)? === 946 - 947 - 948 -Because the new version of -NB firmware has updated the factory reset function, users can choose to restore all parameters to factory Settings, or keep the password to restore the rest of the parameters to factory Settings. 949 - 950 -This update changes the password address of the firmware, so the password will be invalid after the customer upgrades from the old version of firmware (without FDR1 function) to the new version of firmware (with FDR1 function). 951 - 952 -Two different restore factory Settings configurations. 953 - 954 -(% style="color:blue" %)**AT command:** 955 - 956 -* (% style="color:#037691; font-weight:bold" %)**AT+FDR**(%%)** **~/~/ Reset Parameters to Factory Default. 957 -* (% style="color:#037691; font-weight:bold" %)**AT+FDR1**(%%)** **~/~/ Reset parameters to factory default values except for passwords.(new) 958 - 959 -=== Version Confirmation === 960 - 961 -We are now dividing the **old firmware**(without FDR1 function) with the **new firmware**(with FDR1 function) by whether it contains FDR1 functionality. Please refer to the table: 962 - 963 -(% border="1" style="background-color:#f2f2f2; width:510px" %) 964 -|(% style="background-color:#4f81bd; color:white; width:210px" %)**General Model**|(% style="background-color:#4f81bd; color:white; width:150px" %)((( 965 -**Firmware version** 966 - 967 -**(without FDR1 function)** 968 -)))|(% style="background-color:#4f81bd; color:white; width:150px" %)((( 969 -**Firmware version** 970 - 971 -**(with FDR1 function)** 972 -))) 973 -|(% style="width:210px" %)((( 974 -CPL03-NB, S31-NB, SN50V3-NB, TS01-NB, D20-NB, DS03A-NB, DDS04-NB, DDS45-NB, DDS20-NB, DDS75-NB, LDS12-NB, LDS40-NB, LMS01-NB, MDS120-NB, MDS200-NB, SE01-NB, SPH01-NB; 975 -)))|(% style="width:150px" %)Before V1.2.1|(% style="width:150px" %)After V1.2.1 (including V1.2.1) 976 -|(% style="width:210px" %)((( 977 -WL03A-NB, SDI-12-NB; 978 -)))|(% style="width:150px" %)Before V1.0.2|(% style="width:150px" %)((( 979 -After V1.0.8 (including V1.0.2) 980 -))) 981 -|(% style="width:210px" %)((( 982 -SW3L-NB, PS-NB; 983 -)))|(% style="width:150px" %)Before V1.0.5|(% style="width:150px" %)((( 984 -After V1.0.5 (including V1.0.5) 985 -))) 986 -|(% style="width:210px" %)RS485-NB|(% style="width:150px" %)Before V1.0.8|(% style="width:150px" %)After V1.0.8 (including V1.0.8) 987 - 988 -=== UART connection and firmware update methods === 989 - 990 - 991 -Users can query passwords only using the UART interface via the STM32CubeProgrammer. 992 - 993 -See **[[UART Connection>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H2.3UARTConnectionforSN50v3basemotherboard]]**. 994 - 995 -update firmware through UART TTL interface :** [[Instruction>>url:http://wiki.dragino.com/xwiki/bin/view/Main/UART_Access_for_NB_ST_BC660K-GL/#H4.2UpdateFirmware28Assumethedevicealreadyhaveabootloader29]]**. 996 - 997 - 998 -=== query the password via STM32CubeProgrammer === 999 - 1000 - 1001 -Users can use the password address to query the password through STM32CubeProgrammer. 1002 - 1003 -* The password address for old firmware(without FDR1 function) : **0x08019000** 1004 -* The password address for new firmware(with FDR1 function) : **0x08025D00** 1005 - 1006 -(% style="color:red" %)**Notice: The password can only be queried after the firmware is run once.** 1007 - 1008 - 1009 -**Procedure for querying the password(old firmware):** 1010 - 1011 -* After the firmware upgrade is complete, switch back to the **FLASH** and reset the node to **run the firmware once**. 1012 -* Then place the switch at the **ISP** and connect to the STM32CubeProgrammer (same as when burning the firmware). 1013 -* Click "Device memory", enter **0x08019000** in "Address", and click "Read" 1014 -* Find the 0x08019000 address field and then read the current password as shown in the screenshot below. 1015 - 1016 -[[image:http://wiki.dragino.com/xwiki/bin/download/Why%20can%27t%20the%20password%20access%20AT%20command%20after%20upgrade%28-NB%29%3F/WebHome/image-20240827171901-3.png?width=912&height=528&rev=1.1||alt="image-20240827171901-3.png"]] 1017 - 1018 - 1019 -**Procedure for querying the password(new firmware):** 1020 - 1021 -Refer to [[the old and new firmware division>>http://wiki.dragino.com/xwiki/bin/view/Main/General%20Configure%20to%20Connect%20to%20IoT%20server%20for%20-NB%20%26%20-NS%20NB-IoT%20models/#HVersionConfirmation]] above, and run the firmware first after updating the firmware. 1022 - 1023 -* After the firmware upgrade is complete, switch back to the **FLASH** and reset the node to **run the new firmware once**. 1024 -* Then place the switch at the **ISP** and connect to the STM32CubeProgrammer (same as when burning the firmware). 1025 -* Click "Device memory", enter **0x08025D00** in "Address", and click "Read" 1026 -* Find the 0x08025D00 address field and then read the current password as shown in the screenshot below. 1027 - 1028 -[[image:http://wiki.dragino.com/xwiki/bin/download/Why%20can%27t%20the%20password%20access%20AT%20command%20after%20upgrade%28-NB%29%3F/WebHome/image-20240827180414-1.png?width=910&height=527&rev=1.1||alt="image-20240827180414-1.png"]] 1029 - 1030 - 1031 - 1032 -=== Special case === 1033 - 1034 - 1035 -If the user has never changed the password manually, the user cannot find the valid password through the above two password addresses. In this case, the valid password is still the original password on the node box label (**AT+PIN**). 1036 - 1037 -Invalid query screenshot example: 1038 - 1039 - 1040 -[[image:http://wiki.dragino.com/xwiki/bin/download/Why%20can%27t%20the%20password%20access%20AT%20command%20after%20upgrade%28-NB%29%3F/WebHome/image-20240827181447-4.png?width=889&height=519&rev=1.1||alt="image-20240827181447-4.png"]] 1041 - 1042 -[[image:http://wiki.dragino.com/xwiki/bin/download/Why%20can%27t%20the%20password%20access%20AT%20command%20after%20upgrade%28-NB%29%3F/WebHome/image-20240827181431-3.png?width=892&height=515&rev=1.1||alt="image-20240827181431-3.png"]] 1043 - 1044 - 1045 - 1046 1046