... ... @@ -634,11 +634,47 @@
634 634  [[image:image-20230807233631-2.png]]
635 635  
636 636  
637 -= 4. FAQ =
638 638  
639 -== 4.1 What is the usage of Multi Sampling and One Uplink? ==
640 640  
639 += 4. MQTT/UDP/TCP downlink =
641 641  
641 +== 4.1 MQTT (via MQTT.fx) ==
642 +
643 +Configure MQTT connections properly and send downlink commands to configure nodes through the Publish function of MQTT.fx//.//
644 +
645 +**1.** **Configure node MQTT connection (via MQTT.fx):**
646 +
647 +(% style="color:blue" %)**AT command:**
648 +
649 +* (% style="color:#037691" %)**AT+PRO=3,0 or 3,5 ** (%%) **~/~/ hex format or json format**
650 +
651 +* (% style="color:#037691" %)**AT+SUBTOPIC=User Defined**
652 +
653 +* (% style="color:#037691" %)**AT+PUBTOPIC=User Defined**
654 +
655 +* (% style="color:#037691" %)**AT+UNAME=<device name> or User Defined**
656 +
657 +* (% style="color:#037691" %)**AT+PWD=<device name> or User Defined**
658 +
659 +
660 +* (% style="color:#037691" %)**AT+SERVADDR=8.217.91.207,1883 ** (%%) ~/~/ to set MQTT server address and port
661 +
662 +(% style="color:red" %)**Note: To uplink and downlink via MQTT.fx, we need set the publish topic and subscribe topic different, for example: AT+SUBTOPIC=SE01_SUB & AT+PUBTOPIC=SE01_PUB.**
663 +
664 +[[image:image-20240417180145-2.png||height="545" width="737"]]
665 +
666 +[[image:image-20240417180737-3.png||height="544" width="738"]]
667 +
668 +
669 +
670 +
671 +
672 +
673 += 5. FAQ =
674 +
675 +== 5.1 What is the usage of Multi Sampling and One Uplink? ==
676 +
677 +
642 642  The NB series has the feature for Multi Sampling and one uplink. See one of them
643 643  
644 644  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SN50v3-NB_BN-IoT_Sensor_Node_User_Manual/#H2.5Multi-SamplingsandOneuplink>>http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SN50v3-NB_BN-IoT_Sensor_Node_User_Manual/#H2.5Multi-SamplingsandOneuplink]]
... ... @@ -653,7 +653,7 @@
653 653  1*. **AT+TDC=7200**  ~/~/ Uplink every 2 hours.
654 654  1*. this will mean each uplink will actually include the 6 uplink data (24 set data which cover 12 hours). So if device doesn't lost 6 continue data. There will not data lost.
655 655  
656 -== 4.2 Why the uplink JSON format is not standard? ==
692 +== 5.2 Why the uplink JSON format is not standard? ==
657 657  
658 658  
659 659  The json format in uplink packet is not standard Json format. Below is the example. This is to make the payload as short as possible, due to NB-IoT transmit limition, a standard Json is not able to include 32 sets of sensors data with timestamp.
... ... @@ -663,9 +663,9 @@
663 663  [[image:image-20240229233154-1.png]]
664 664  
665 665  
666 -= 5. Trouble Shooting: =
702 += 6. Trouble Shooting: =
667 667  
668 -== 5.1 Checklist for debuging Network Connection issue. Signal Strenght:99 issue. ==
704 +== 6.1 Checklist for debuging Network Connection issue. Signal Strenght:99 issue. ==
669 669  
670 670  
671 671  There are many different providers provide NB-IoT service in the world. They might use different band, different APN & different operator configuration. Which makes connection to NB-IoT network is complicate.
... ... @@ -692,7 +692,7 @@
692 692  If you have check all above and still fail. please send console log files (as many as possible) to [[support@dragino.com>>mailto:support@dragino.com]] so we can check.
693 693  
694 694  
695 -== 5.2 Issue: "NBIOT did not respond" ==
731 +== 6.2 Issue: "NBIOT did not respond" ==
696 696  
697 697  
698 698  (% class="box errormessage" %)
... ... @@ -720,7 +720,7 @@
720 720  [[image:image-20240208001740-1.png]]
721 721  
722 722  
723 -== 5.3 Issue: "Failed to readI MSI number" ==
759 +== 6.3 Issue: "Failed to readI MSI number" ==
724 724  
725 725  
726 726  (% class="box errormessage" %)
... ... @@ -734,7 +734,7 @@
734 734  Make sure that the SIM card is insert in correct direction and device is power off/on during insert. Here is reference link: [[Insert SIM Card>>||anchor="H2.1GeneralConfiguretoattachnetwork"]].
735 735  
736 736  
737 -== 5.4 Why sometime the AT Command is slow in reponse? ==
773 +== 6.4 Why sometime the AT Command is slow in reponse? ==
738 738  
739 739  
740 740  When the MCU is communicating with the NB-IoT module, the MCU response of AT Command will become slower, it might takes several seconds to response.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved