Last modified by Mengting Qiu on 2025/07/03 18:55
From version 146.1
edited by Edwin Chen
on 2024/03/03 16:50
on 2024/03/03 16:50
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 9 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.kai - Content
-
... ... @@ -25,7 +25,7 @@ 25 25 1. Power Off End Node ( See below for the power off/on position) 26 26 1. Insert the SIM card to Sensor. ( See below for direction) 27 27 1. Power On End Node 28 -1. [[Configure APN>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20configure%20APN%20in%20the%20node/]] in the sensor (AT+APN=<APN>) 28 +1. [[Configure APN>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20configure%20APN%20in%20the%20node/]] in the sensor (AT+APN=<APN>), example AT+APN=iot.1nce.net 29 29 30 30 [[image:image-20240208102804-1.png||height="286" width="696"]] 31 31 ... ... @@ -40,8 +40,8 @@ 40 40 |(% style="width:117px" %)**[[1NCE>>https://1nce.com]]**|(% style="width:151px" %)iot.1nce.net|(% style="width:474px" %)((( 41 41 **[[Coverage Reference Link>>https://1nce.com/en-ap/1nce-connect]]** 42 42 43 -Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Finland, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Malta, Netherlands, Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, US Virgin Islands 44 -)))|(% style="width:135px" %) 43 +Austria, Belgium, Bulgaria, Croatia, Czech Republic, Denmark, Finland, Germany, Great Britain, Greece, Hungary, Ireland, Italy, Latvia, Malta, Netherlands, Norway, Puerto Rico, Russia, Slovak , Republic, Slovenia, Spain, Sweden, Switzerland, Taiwan, USA, UK, US Virgin Islands 44 +)))|(% style="width:135px" %)UK: Band20 45 45 |(% style="width:117px" %)China Mobile|(% style="width:151px" %)No need configure|(% style="width:474px" %)China Mainland, HongKong|(% style="width:135px" %) 46 46 |(% style="width:117px" %)China Telecom|(% style="width:151px" %)ctnb|(% style="width:474px" %)China Mainland|(% style="width:135px" %) 47 47 ... ... @@ -48,12 +48,12 @@ 48 48 == 2.2 Speed Up Network Attach time == 49 49 50 50 51 -BC660K-GL supports multi bands (% style="color:blue" %)**B1/B2/B3/B4/B5/B8/B12/B13/B14/B17/B18/B19/B20/B25/B28/B66/B70/B85. **(%%) It will search one by one and try to attach, this will take a lot of time and even cause attach fail and show Signal Strenght:99. User can lock the band to specify band for its operator to make this faster. 51 +BC660K-GL supports multi bands (% style="color:blue" %)**B1/B2/B3/B4/B5/B8/B12/B13/B14/B17/B18/B19/B20/B25/B28/B66/B70/B85. **(%%) It will search one by one and try to attach, this will take a lot of time and even cause attach fail and show **Signal Strenght:99**. User can lock the band to specify band for its operator to make this faster. 52 52 53 53 (% style="color:#037691" %)**AT+QBAND? **(%%) ~/~/ Check what is the current used frequency band 54 54 (% style="color:#037691" %)**AT+QBAND=1,4 **(%%) ~/~/ Set to use 1 frequency band. Band4 55 55 (% style="color:#037691" %)**Europe General**(%%) **AT+QBAND=2,8,20 ** ~/~/ Set to use 2 frequency bands. Band 8 and Band 20 56 -(% style="color:#037691" %)**Global General**(%%) : **AT+QBAND=1 1,8,20,28,2,4,12,13,66,85,5,4**56 +(% style="color:#037691" %)**Global General**(%%) : **AT+QBAND=10,8,20,28,2,4,12,13,66,85,5** 57 57 58 58 (% style="color:#037691" %)**Verizon**(%%)** ** AT+QBAND=1,13 59 59 (% style="color:#037691" %)**AT&T**(%%) AT+QBAND=3,12,4,2 ... ... @@ -62,6 +62,7 @@ 62 62 63 63 After connection is successful, user can use (% style="color:#037691" %)**AT+QENG=0 **(%%) to check which band is actually in used. 64 64 65 +By default, device will search network for 5 minutes. User can set the time to 10 minutes by (% style="color:#037691" %)**AT+CSQTIME=10 **(%%)so it can search longer. 65 65 66 66 See bands used for different provider:** [[NB-IoT Deployment , Bands, Operator list>>http://wiki.dragino.com/xwiki/bin/view/Main/NB-IoT%20Deployment%20%2C%20Bands%2C%20Operator%20list/]]** 67 67 ... ... @@ -634,11 +634,68 @@ 634 634 [[image:image-20230807233631-2.png]] 635 635 636 636 637 -= 4.FAQ=638 +== 3.9 AWS Connection == 638 638 639 -== 4.1 What is the usage of Multi Sampling and One Uplink? == 640 640 641 +Users can refer to [[Dragino NB device connection to AWS platform instructions>>http://wiki.dragino.com/xwiki/bin/view/Dragino%20NB%20device%20connection%20to%20AWS%20platform%20instructions/#H1.LogintotheplatformandfindIoTcore]] 641 641 643 + 644 + 645 + 646 += 4. MQTT/UDP/TCP downlink = 647 + 648 +== 4.1 MQTT (via MQTT.fx) == 649 + 650 +Configure MQTT connections properly and send downlink commands to configure nodes through the Publish function of MQTT.fx//.// 651 + 652 +**1.** Configure node MQTT connection (via MQTT.fx): 653 + 654 +(% style="color:blue" %)**AT command:** 655 + 656 +* (% style="color:#037691" %)**AT+PRO=3,0 or 3,5 ** (%%)~/~/ hex format or json format 657 + 658 +* (% style="color:#037691" %)**AT+SUBTOPIC=User Defined** 659 + 660 +* (% style="color:#037691" %)**AT+PUBTOPIC=User Defined** 661 + 662 +* (% style="color:#037691" %)**AT+UNAME=<device name> or User Defined** 663 + 664 +* (% style="color:#037691" %)**AT+PWD=<device name> or User Defined** 665 + 666 +* (% style="color:#037691" %)**AT+SERVADDR=8.217.91.207,1883 ** (%%) ~/~/ to set MQTT server address and port 667 + 668 +(% style="color:red" %)**Note: To uplink and downlink via MQTT.fx, we need set the publish topic and subscribe topic different, for example: AT+SUBTOPIC=SE01_SUB & AT+PUBTOPIC=SE01_PUB.** 669 + 670 +[[image:image-20240417180145-2.png||height="434" width="587"]][[image:image-20240417180737-3.png||height="431" width="584"]] 671 + 672 + 673 +**2. **When the node uplink packets, we can observe the data in MQTT.fx. 674 + 675 +[[image:image-20240418144337-1.png||height="709" width="802"]] 676 + 677 +**3. **The downlink command can be successfully sent only when the downlink port is open. 678 + 679 + The downlink port is opened for about 3 seconds after uplink packets are sent. 680 + 681 + Therefore, when we see the node uplink packets in the **Subscribe** window, we need to immediately switch to the **publish** window to publish the **hex format** command. 682 + 683 +[[image:image-20240418150435-3.png||height="582" width="659"]] 684 + 685 +[[image:image-20240418150932-4.png||height="492" width="1061"]] 686 + 687 +(% style="color:red" %)**Note: Users can edit the hex command in advance. When the node uplink, directly click the publish button several times to increase the success rate of command configuration.** 688 + 689 + 690 + 691 + 692 + 693 + 694 + 695 += 5. FAQ = 696 + 697 +== 5.1 What is the usage of Multi Sampling and One Uplink? == 698 + 699 + 642 642 The NB series has the feature for Multi Sampling and one uplink. See one of them 643 643 644 644 [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SN50v3-NB_BN-IoT_Sensor_Node_User_Manual/#H2.5Multi-SamplingsandOneuplink>>http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/SN50v3-NB_BN-IoT_Sensor_Node_User_Manual/#H2.5Multi-SamplingsandOneuplink]] ... ... @@ -651,20 +651,21 @@ 651 651 1*. **AT+TR=1800** ~/~/ The unit is seconds, and the default is to record data once every 1800 seconds (30 minutes, the minimum can be set to 180 seconds) 652 652 1*. **AT+NOUD=24** ~/~/ The device uploads 24 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 653 653 1*. **AT+TDC=7200** ~/~/ Uplink every 2 hours. 654 -1*. this will mean each uplink will actually include the 6 uplink data (24 set data which cover 12 hours). So if device doesn ;t lost 6 continue data. There will not data lost.712 +1*. this will mean each uplink will actually include the 6 uplink data (24 set data which cover 12 hours). So if device doesn't lost 6 continue data. There will not data lost. 655 655 714 +== 5.2 Why the uplink JSON format is not standard? == 656 656 657 -== 4.2 Why the uplink JSON format is not standard? == 658 658 659 - 660 660 The json format in uplink packet is not standard Json format. Below is the example. This is to make the payload as short as possible, due to NB-IoT transmit limition, a standard Json is not able to include 32 sets of sensors data with timestamp. 661 661 719 +The firmware version released after 2024, Mar will use change back to use Json format. Detail please check changelog. 720 + 662 662 [[image:image-20240229233154-1.png]] 663 663 664 664 665 -= 5. Trouble Shooting: =724 += 6. Trouble Shooting: = 666 666 667 -== 5.1 Checklist for debuging Network Connection issue. Signal Strenght:99 issue. ==726 +== 6.1 Checklist for debuging Network Connection issue. Signal Strenght:99 issue. == 668 668 669 669 670 670 There are many different providers provide NB-IoT service in the world. They might use different band, different APN & different operator configuration. Which makes connection to NB-IoT network is complicate. ... ... @@ -691,7 +691,7 @@ 691 691 If you have check all above and still fail. please send console log files (as many as possible) to [[support@dragino.com>>mailto:support@dragino.com]] so we can check. 692 692 693 693 694 -== 5.2 Issue: "NBIOT did not respond" ==753 +== 6.2 Issue: "NBIOT did not respond" == 695 695 696 696 697 697 (% class="box errormessage" %) ... ... @@ -719,7 +719,7 @@ 719 719 [[image:image-20240208001740-1.png]] 720 720 721 721 722 -== 5.3 Issue: "Failed to readI MSI number" ==781 +== 6.3 Issue: "Failed to readI MSI number" == 723 723 724 724 725 725 (% class="box errormessage" %) ... ... @@ -733,7 +733,7 @@ 733 733 Make sure that the SIM card is insert in correct direction and device is power off/on during insert. Here is reference link: [[Insert SIM Card>>||anchor="H2.1GeneralConfiguretoattachnetwork"]]. 734 734 735 735 736 -== 5.4 Why sometime the AT Command is slow in reponse? == 795 +== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.4 Why sometime the AT Command is slow in reponse?(%%) == 737 737 738 738 739 739 When the MCU is communicating with the NB-IoT module, the MCU response of AT Command will become slower, it might takes several seconds to response. ... ... @@ -741,4 +741,68 @@ 741 741 [[image:image-20240226111928-1.png]] 742 742 743 743 803 +== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.5 What is the Downlink Command by the NB device?(%%) == 804 + 805 +(% data-sider-select-id="bb6e9353-0c3f-473c-938d-4b416c9a03e6" %) 806 +=== UDP: === 807 + 808 +(% data-sider-select-id="14a4790e-7faa-4508-a4dd-7605a53f1cb3" %) 809 +Its downlink command is the same as the AT command, but brackets are required. 810 +Example: 811 + 812 +{AT+TDC=300} 813 + 814 + 815 +(% data-sider-select-id="90b80f1a-e924-4c8a-afc5-4429e019a657" %) 816 +=== MQTT: === 817 + 818 +Json: 819 + 820 +The Json format in MQTT mode needs to be configured with all commands. 821 +If you have configurations that need to be changed, please change them in the template below. 822 +Template: 823 + 824 +{ 825 +"AT+SERVADDR":"119.91.62.30,1882", 826 +"AT+CLIENT":"JwcXKjQBNhQ2JykDDAA5Ahs", 827 +"AT+UNAME":"usenamedragino", 828 +"AT+PWD":"passworddragino", 829 +"AT+PUBTOPIC":"123", 830 +"AT+SUBTOPIC":"321", 831 +"AT+TDC":"7200", 832 +"AT+INTMOD":"0", 833 +"AT+APN":"NULL", 834 +"AT+5VT":"0", 835 +"AT+PRO":"3,5", 836 +"AT+TR":"900", 837 +"AT+NOUD":"0", 838 +"AT+CSQTIME":"5", 839 +"AT+DNSTIMER":"0", 840 +"AT+TLSMOD":"0,0", 841 +"AT+MQOS":"0", 842 +"AT+TEMPALARM1":"0", 843 +"AT+TEMPALARM2":"10", 844 +"AT+TEMPALARM3":"0" 845 +} 846 + 847 +Hex: 848 + 849 +MQTT's hex format. Since many commands need to support strings, only a few commands are supported. 850 + 851 +The supported commands are consistent with LoRaWAN's hex commands. 852 +Please refer to the following link to obtain the hex format: 853 + 854 +[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20AT%20Commands%20and%20Downlink%20Command/]] 855 + 856 + 857 +== (% data-sider-select-id="765eceff-93b1-40ee-800b-b7b7d022ef8a" %)6.6 How to obtain device logs?(%%) == 858 + 859 +* **AT Command: AT** **+GETLOG** 860 + 861 +This command can be used to query upstream logs of data packets. 862 + 863 +[[image:image-20240701114700-1.png]] 864 + 865 + 866 + 744 744
- image-20240417173549-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +70.3 KB - Content
- image-20240417180145-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +104.1 KB - Content
- image-20240417180737-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.7 KB - Content
- image-20240418144337-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +95.1 KB - Content
- image-20240418144714-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +50.3 KB - Content
- image-20240418150435-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +44.1 KB - Content
- image-20240418150932-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.ting - Size
-
... ... @@ -1,0 +1,1 @@ 1 +103.4 KB - Content
- image-20240701114700-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +291.5 KB - Content
- image-20240729141300-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.kai - Size
-
... ... @@ -1,0 +1,1 @@ 1 +176.9 KB - Content