... ... @@ -22,13 +22,9 @@
22 22  To attache NB-IoT sensors to NB-IoT Network, You need to:
23 23  
24 24  1. Get a NB-IoT SIM card from Service Provider. (Not the same as the SIM card we use in mobile phone)
25 -1. Power Off End Node ( See below for the power off/on position)
26 -1. Insert the SIM card to Sensor. ( See below for direction)
27 -1. Power On End Node
25 +1. Insert the SIM card to Sensor
28 28  1. [[Configure APN>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20configure%20APN%20in%20the%20node/]] in the sensor (AT+APN=<APN>)
29 29  
30 -[[image:image-20240208102804-1.png||height="286" width="696"]]
31 -
32 32  [[image:image-20230808205045-1.png||height="293" width="438"]]
33 33  
34 34  After doing above, the NB-IoT Sensors should be able to attach to NB-IoT network .
... ... @@ -94,6 +94,8 @@
94 94  
95 95  * (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5601**  (%%) ~/~/  Set UDP server address and port
96 96  
93 +* (% style="color:#037691" %)**AT+CFM=1**    (%%) ~/~/  If the server does not respond, this command is unnecessary
94 +
97 97  [[image:image-20230802112413-2.png]]
98 98  
99 99  
... ... @@ -671,7 +671,7 @@
671 671  If you have check all above and still fail. please send console log files (as many as possible) to [[support@dragino.com>>mailto:support@dragino.com]] so we can check.
672 672  
673 673  
674 -== 5.2 Issue: "NBIOT did not respond" ==
672 +== 5.2 NBIOT did not respond issue. ==
675 675  
676 676  (% class="box errormessage" %)
677 677  (((
... ... @@ -696,26 +696,3 @@
696 696  4) push reset button.
697 697  
698 698  [[image:image-20240208001740-1.png]]
699 -
700 -
701 -== 5.3 Issue: "Failed to readI MSI number" ==
702 -
703 -(% class="box errormessage" %)
704 -(((
705 -[18170]Failed to read IMSI:1umber.
706 -[20109]Failed to read IMSI numoer.
707 -[22048]Failed to read IMSI number.
708 -[29842lRestart the module...
709 -)))
710 -
711 -Make sure that the SIM card is insert in correct direction and device is power off/on during insert. Here is reference link: [[Insert SIM Card>>||anchor="H2.1GeneralConfiguretoattachnetwork"]].
712 -
713 -
714 -== 5.4 Why sometime the AT Command is slow in reponse? ==
715 -
716 -When the MCU is communicating with the NB-IoT module, the MCU response of AT Command will become slower, it might takes several seconds to response.
717 -
718 -[[image:image-20240226111928-1.png]]
719 -
720 -
721 -
image-20240208102804-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -507.6 KB
Content
image-20240226111928-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -52.0 KB
Content