Content
... ... @@ -22,9 +22,13 @@
22 22  To attache NB-IoT sensors to NB-IoT Network, You need to:
23 23  
24 24  1. Get a NB-IoT SIM card from Service Provider. (Not the same as the SIM card we use in mobile phone)
25 -1. Insert the SIM card to Sensor
25 +1. Power Off End Node ( See below for the power off/on position)
26 +1. Insert the SIM card to Sensor. ( See below for direction)
27 +1. Power On End Node
26 26  1. [[Configure APN>>http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20configure%20APN%20in%20the%20node/]] in the sensor (AT+APN=<APN>)
27 27  
30 +[[image:image-20240208102804-1.png||height="286" width="696"]]
31 +
28 28  [[image:image-20230808205045-1.png||height="293" width="438"]]
29 29  
30 30  After doing above, the NB-IoT Sensors should be able to attach to NB-IoT network .
... ... @@ -90,8 +90,6 @@
90 90  
91 91  * (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5601**  (%%) ~/~/  Set UDP server address and port
92 92  
93 -* (% style="color:#037691" %)**AT+CFM=1**    (%%) ~/~/  If the server does not respond, this command is unnecessary
94 -
95 95  [[image:image-20230802112413-2.png]]
96 96  
97 97  
... ... @@ -669,7 +669,7 @@
669 669  If you have check all above and still fail. please send console log files (as many as possible) to [[support@dragino.com>>mailto:support@dragino.com]] so we can check.
670 670  
671 671  
672 -== 5.2 NBIOT did not respond issue. ==
674 +== 5.2 Issue: "NBIOT did not respond" ==
673 673  
674 674  (% class="box errormessage" %)
675 675  (((
... ... @@ -694,3 +694,26 @@
694 694  4) push reset button.
695 695  
696 696  [[image:image-20240208001740-1.png]]
699 +
700 +
701 +== 5.3 Issue: "Failed to readI MSI number" ==
702 +
703 +(% class="box errormessage" %)
704 +(((
705 +[18170]Failed to read IMSI:1umber.
706 +[20109]Failed to read IMSI numoer.
707 +[22048]Failed to read IMSI number.
708 +[29842lRestart the module...
709 +)))
710 +
711 +Make sure that the SIM card is insert in correct direction and device is power off/on during insert. Here is reference link: [[Insert SIM Card>>||anchor="H2.1GeneralConfiguretoattachnetwork"]].
712 +
713 +
714 +== 5.4 Why sometime the AT Command is slow in reponse? ==
715 +
716 +When the MCU is communicating with the NB-IoT module, the MCU response of AT Command will become slower, it might takes several seconds to response.
717 +
718 +[[image:image-20240226111928-1.png]]