Version 7.2 by Xiaoling on 2022/05/27 08:45

Show last authors
1 (% class="wikigeneratedid" %)
2 **~ Contents:**
3
4 {{toc/}}
5
6
7 = 1. Introduction =
8
9 This article shows the firmware upgrade method and troubleshooting for the below models Dragino sensors.
10
11
12 = 2. Model and Connection =
13
14 == 2.1 LDS01/LWL01 ==
15
16 [[Firmware Location>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Firmware/]]
17
18 (((
19 Pin Mapping:
20 )))
21
22 [[image:image-20220527083845-1.png||height="473" width="915"]]
23
24 LDS01/LWL01 Pin Mapping
25
26
27 DAP-Link Connection:
28
29 [[image:image-20220527083959-2.png]]
30
31 Connect DAP-Link
32
33
34 == 2.2 LDS02/LWL02 ==
35
36 [[Firmware Location(same as LDS01)>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Firmware/]]
37
38 (((
39 Pin Mapping:
40 )))
41
42 [[image:image-20220527084041-3.png||height="378" width="907"]]
43
44 LDS02/LDS02 v2.0 Pin Mapping
45
46
47 [[image:image-20220527084230-4.png]]
48
49 LDS02/LDS02 v2.2 Pin Mapping
50
51
52 == 2.3 LHT52 ==
53
54 [[Firmware Location>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LHT52/firmware/]]
55
56 [[image:image-20220527084401-5.png]]
57
58 LHT52 Pin Mapping
59
60
61 = 3. How to Upgrade =
62
63 == 3.1 Use DAP-Link and Connect to the Device as above photos ==
64
65 We need to connect VDD,GND,SWCLK,SWDIO to DAP-Link.
66
67 * Connection method:
68
69 * GND-GND,
70
71 * VDD-3.3V,
72
73 * SWCLK-CLK,
74
75 * SWDIO-SWD
76
77 [[image:image-20220527084505-6.png]]
78
79
80 == 3.2 Install PSoCProgrammer 3.27.1 ==
81
82 (((
83 Download Link: [[PSoCProgrammer3.27.1>>url:https://www.dragino.com/downloads/index.php?dir=tools/]]
84 )))
85
86 (((
87 And then use PSoCProgrammer to upgrade the firmware (must use this version: PSoCProgrammer3.27.1)
88 )))
89
90 [[image:https://wiki.dragino.com/images/0/0f/Ppp1.png||alt="Ppp1.png" height="68" width="318"]]
91
92
93 == 3.3 Download Sensor Firmware ==
94
95 Downlink sensor firmware to prepare the update
96
97
98 == 3.4 Upgrade Firmware ==
99
100 Open PSOC Programmer, select the default configuration, no need to modify
101
102 [[image:https://wiki.dragino.com/images/thumb/9/94/Ppp10.png/600px-Ppp10.png||alt="Ppp10.png" height="198" width="600"]]
103
104 Click the file icon to select the software to be burned:
105
106 [[image:https://wiki.dragino.com/images/thumb/d/d0/Ppp11.png/600px-Ppp11.png||alt="Ppp11.png" height="218" width="600"]]
107
108 [[image:https://wiki.dragino.com/images/thumb/e/ec/Ppp12.png/600px-Ppp12.png||alt="Ppp12.png" height="265" width="600"]]
109
110
111 (((
112 Click the download icon, and the progress bar as shown in the figure below will appear. When PASS appears, it proves that the burning is successful.
113 )))
114
115 [[image:https://wiki.dragino.com/images/thumb/e/e2/Ppp13.png/600px-Ppp13.png||alt="Ppp13.png" height="337" width="600"]]
116
117 [[image:https://wiki.dragino.com/images/thumb/6/6f/Ppp14.png/600px-Ppp14.png||alt="Ppp14.png" height="338" width="600"]]
118
119 (((
120 It is very important to press the reset button after the upgrade., this is to set the device to work in Low Power mode
121 )))
122
123 (((
124 *If you change different LoRa Frequency Bands/Region, you need using AT+FDR command to restore factory data after program success
125 )))
126
127 = 4. Trouble Shooting =
128
129 == 4.1 Unable to detect upgrade ==
130
131 * Try to shot the bootloader pin to GND and reset the device. So the device will runs in bootloader mode.
132 * Or use AT+IREBOOT=7 to set the device to work in bootloader mode.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0