Show last authors
1 = 1. Introduction =
2
3 This article shows the firmware upgrade method and troubleshooting for the below models Dragino sensors.
4
5 = 2. Model and Connection =
6
7 == 2.1 LDS01/LWL01 ==
8
9 [[Firmware Location>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Firmware/]]
10
11 Pin Mapping:
12
13 [[image:https://wiki.dragino.com/images/thumb/e/e3/ASR_Upgrade_1.png/600px-ASR_Upgrade_1.png||height="298" width="566"]]
14
15 LDS01/LWL01 Pin Mapping
16
17 DAP-Link Connection:
18
19 [[image:https://wiki.dragino.com/images/thumb/7/79/ASR_Upgrade_2.jpg/600px-ASR_Upgrade_2.jpg||height="379" width="504"]]
20
21 Connect DAP-Link
22
23
24 == 2.2 LDS02/LWL02 ==
25
26 [[Firmware Location(same as LDS01)>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Firmware/]]
27
28 Pin Mapping:
29
30 [[image:https://wiki.dragino.com/images/thumb/8/8b/ASR_Upgrade_LDS02_1.png/600px-ASR_Upgrade_LDS02_1.png||height="256" width="600"]]
31
32 LDS02/LDS02 v2.0 Pin Mapping
33
34 [[image:https://wiki.dragino.com/images/thumb/1/1c/ASR_Upgrade_LDS02_2.png/600px-ASR_Upgrade_LDS02_2.png||height="246" width="547"]]
35
36 LDS02/LDS02 v2.2 Pin Mapping
37
38
39 == 2.3 LHT52 ==
40
41 [[Firmware Location>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LHT52/firmware/]]
42
43 [[image:https://wiki.dragino.com/images/thumb/e/e0/ASR_Upgrade_LHT52_1.png/600px-ASR_Upgrade_LHT52_1.png||height="401" width="553"]]
44
45 LHT52 Pin Mapping
46
47 = 3. How to Upgrade =
48
49 == 3.1 Use DAP-Link and Connect to the Device as above photos ==
50
51 We need to connect VDD,GND,SWCLK,SWDIO to DAP-Link.
52
53 * Connection method:
54
55 * GND-GND,
56
57 * VDD-3.3V,
58
59 * SWCLK-CLK,
60
61 * SWDIO-SWD
62
63 [[image:https://wiki.dragino.com/images/8/81/DAPlink.png||alt="DAPlink.png" height="539" width="334"]]
64
65
66 == 3.2 Install PSoCProgrammer 3.27.1 ==
67
68 Download Link: [[PSoCProgrammer3.27.1>>url:https://www.dragino.com/downloads/index.php?dir=tools/]]
69
70 And then use PSoCProgrammer to upgrade the firmware (must use this version: PSoCProgrammer3.27.1)
71
72 [[image:https://wiki.dragino.com/images/0/0f/Ppp1.png||alt="Ppp1.png" height="68" width="318"]]
73
74
75 == 3.3 Download Sensor Firmware ==
76
77 Downlink sensor firmware to prepare the update
78
79
80 == 3.4 Upgrade Firmware ==
81
82 Open PSOC Programmer, select the default configuration, no need to modify
83
84 [[image:https://wiki.dragino.com/images/thumb/9/94/Ppp10.png/600px-Ppp10.png||alt="Ppp10.png" height="198" width="600"]]
85
86 Click the file icon to select the software to be burned:
87
88 [[image:https://wiki.dragino.com/images/thumb/d/d0/Ppp11.png/600px-Ppp11.png||alt="Ppp11.png" height="218" width="600"]]
89
90 [[image:https://wiki.dragino.com/images/thumb/e/ec/Ppp12.png/600px-Ppp12.png||alt="Ppp12.png" height="265" width="600"]]
91
92
93 Click the download icon, and the progress bar as shown in the figure below will appear. When PASS appears, it proves that the burning is successful.
94
95 [[image:https://wiki.dragino.com/images/thumb/e/e2/Ppp13.png/600px-Ppp13.png||alt="Ppp13.png" height="337" width="600"]]
96
97 [[image:https://wiki.dragino.com/images/thumb/6/6f/Ppp14.png/600px-Ppp14.png||alt="Ppp14.png" height="338" width="600"]]
98
99 (((
100 It is very important to press the reset button after the upgrade., this is to set the device to work in Low Power mode
101 )))
102
103 (((
104 *If you change different LoRa Frequency Bands/Region, you need using AT+FDR command to restore factory data after program success
105 )))
106
107 = 4. Trouble Shooting =
108
109 == 4.1 Unable to detect upgrade ==
110
111 * Try to shot the bootloader pin to GND and reset the device. So the device will runs in bootloader mode.
112 * Or use AT+IREBOOT=7 to set the device to work in bootloader mode.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved