Show last authors
1 (% class="wikigeneratedid" %)
2 **~ Contents:**
3
4 {{toc/}}
5
6
7 = 1. Introduction =
8
9 This article shows the firmware upgrade method and troubleshooting for the below models Dragino sensors.
10
11 = 2. Model and Connection =
12
13 == 2.1 LDS01/LWL01 ==
14
15 [[Firmware Location>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Firmware/]]
16
17 Pin Mapping:
18
19 [[image:https://wiki.dragino.com/images/thumb/e/e3/ASR_Upgrade_1.png/600px-ASR_Upgrade_1.png||height="298" width="566"]]
20
21 LDS01/LWL01 Pin Mapping
22
23 DAP-Link Connection:
24
25 [[image:https://wiki.dragino.com/images/thumb/7/79/ASR_Upgrade_2.jpg/600px-ASR_Upgrade_2.jpg||height="379" width="504"]]
26
27 Connect DAP-Link
28
29
30 == 2.2 LDS02/LWL02 ==
31
32 [[Firmware Location(same as LDS01)>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Firmware/]]
33
34 Pin Mapping:
35
36 [[image:https://wiki.dragino.com/images/thumb/8/8b/ASR_Upgrade_LDS02_1.png/600px-ASR_Upgrade_LDS02_1.png||height="256" width="600"]]
37
38 LDS02/LDS02 v2.0 Pin Mapping
39
40 [[image:https://wiki.dragino.com/images/thumb/1/1c/ASR_Upgrade_LDS02_2.png/600px-ASR_Upgrade_LDS02_2.png||height="246" width="547"]]
41
42 LDS02/LDS02 v2.2 Pin Mapping
43
44
45 == 2.3 LHT52 ==
46
47 [[Firmware Location>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LHT52/firmware/]]
48
49 [[image:https://wiki.dragino.com/images/thumb/e/e0/ASR_Upgrade_LHT52_1.png/600px-ASR_Upgrade_LHT52_1.png||height="401" width="553"]]
50
51 LHT52 Pin Mapping
52
53 = 3. How to Upgrade =
54
55 == 3.1 Use DAP-Link and Connect to the Device as above photos ==
56
57 We need to connect VDD,GND,SWCLK,SWDIO to DAP-Link.
58
59 * Connection method:
60
61 * GND-GND,
62
63 * VDD-3.3V,
64
65 * SWCLK-CLK,
66
67 * SWDIO-SWD
68
69 [[image:https://wiki.dragino.com/images/8/81/DAPlink.png||alt="DAPlink.png" height="539" width="334"]]
70
71
72 == 3.2 Install PSoCProgrammer 3.27.1 ==
73
74 (((
75 Download Link: [[PSoCProgrammer3.27.1>>url:https://www.dragino.com/downloads/index.php?dir=tools/]]
76 )))
77
78 (((
79 And then use PSoCProgrammer to upgrade the firmware (must use this version: PSoCProgrammer3.27.1)
80 )))
81
82 [[image:https://wiki.dragino.com/images/0/0f/Ppp1.png||alt="Ppp1.png" height="68" width="318"]]
83
84
85 == 3.3 Download Sensor Firmware ==
86
87 Downlink sensor firmware to prepare the update
88
89
90 == 3.4 Upgrade Firmware ==
91
92 Open PSOC Programmer, select the default configuration, no need to modify
93
94 [[image:https://wiki.dragino.com/images/thumb/9/94/Ppp10.png/600px-Ppp10.png||alt="Ppp10.png" height="198" width="600"]]
95
96 Click the file icon to select the software to be burned:
97
98 [[image:https://wiki.dragino.com/images/thumb/d/d0/Ppp11.png/600px-Ppp11.png||alt="Ppp11.png" height="218" width="600"]]
99
100 [[image:https://wiki.dragino.com/images/thumb/e/ec/Ppp12.png/600px-Ppp12.png||alt="Ppp12.png" height="265" width="600"]]
101
102
103 (((
104 Click the download icon, and the progress bar as shown in the figure below will appear. When PASS appears, it proves that the burning is successful.
105 )))
106
107 [[image:https://wiki.dragino.com/images/thumb/e/e2/Ppp13.png/600px-Ppp13.png||alt="Ppp13.png" height="337" width="600"]]
108
109 [[image:https://wiki.dragino.com/images/thumb/6/6f/Ppp14.png/600px-Ppp14.png||alt="Ppp14.png" height="338" width="600"]]
110
111 (((
112 It is very important to press the reset button after the upgrade., this is to set the device to work in Low Power mode
113 )))
114
115 (((
116 *If you change different LoRa Frequency Bands/Region, you need using AT+FDR command to restore factory data after program success
117 )))
118
119 = 4. Trouble Shooting =
120
121 == 4.1 Unable to detect upgrade ==
122
123 * Try to shot the bootloader pin to GND and reset the device. So the device will runs in bootloader mode.
124 * Or use AT+IREBOOT=7 to set the device to work in bootloader mode.
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved