From version < 16.3 >
edited by Xiaoling
on 2023/04/19 17:36
To version < 15.2 >
edited by Xiaoling
on 2022/07/23 08:59
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -32,12 +32,13 @@
32 32  [[image:image-20220527083959-2.png]]
33 33  
34 34  Connect DAP-Link
35 +
35 35  
36 36  
37 37  == 2.2 LDS02/LWL02 ==
38 38  
39 39  
40 -[[Firmware Location(same as LDS01)>>https://www.dropbox.com/sh/9j35mnsxnz0y3ye/AACj5gHGOURGEHCpj-E861Mua?dl=0]]
41 +[[Firmware Location(same as LDS01)>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Firmware/]]
41 41  
42 42  
43 43  (((
... ... @@ -55,10 +55,11 @@
55 55  LDS02/LDS02 v2.2 Pin Mapping
56 56  
57 57  
59 +
58 58  == 2.3 LHT52 ==
59 59  
60 60  
61 -[[Firmware Location>>https://www.dropbox.com/sh/ayxhuf5dihtfu6c/AABRe_suu54EdTSFZIbD7t-ea?dl=0]]
63 +[[Firmware Location>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LHT52/firmware/]]
62 62  
63 63  [[image:image-20220527084401-5.png]]
64 64  
... ... @@ -65,6 +65,7 @@
65 65  LHT52 Pin Mapping
66 66  
67 67  
70 +
68 68  = 3. How to Upgrade =
69 69  
70 70  == 3.1 Use DAP-Link and Connect to the Device as above photos ==
... ... @@ -94,18 +94,20 @@
94 94  )))
95 95  
96 96  (((
97 -And then use PSoCProgrammer to upgrade the firmware ( (% style="color:red" %) **must use this version: PSoCProgrammer3.27.1** (%%))
100 +And then use PSoCProgrammer to upgrade the firmware (must use this version: PSoCProgrammer3.27.1)
98 98  )))
99 99  
100 100  [[image:image-20220527084537-7.png]]
101 101  
102 102  
106 +
103 103  == 3.3 Download Sensor Firmware ==
104 104  
105 105  
106 -Downlink sensor firmware to prepare the update.
110 +Downlink sensor firmware to prepare the update
107 107  
108 108  
113 +
109 109  == 3.4 Upgrade Firmware ==
110 110  
111 111  
... ... @@ -132,16 +132,17 @@
132 132  
133 133  [[image:image-20220527084907-12.png]]
134 134  
135 -
136 136  (((
137 -(% style="color:red" %)**It is very important to press the reset button after the upgrade., this is to set the device to work in Low Power mode.**
141 +It is very important to press the reset button after the upgrade., this is to set the device to work in Low Power mode
138 138  )))
139 139  
140 140  (((
141 -(% style="color:red" %)**If you change different LoRa Frequency Bands/Region, you need using **(% style="color:blue" %)**AT+FDR **(% style="color:red" %)**command to restore factory data after program success.**
142 -)))
145 +(% style="color:red" %)If you change different LoRa Frequency Bands/Region, you need using AT+FDR command to restore factory data after program success.
143 143  
144 144  
148 +
149 +)))
150 +
145 145  = 4. Trouble Shooting =
146 146  
147 147  == 4.1 Unable to detect upgrade ==
... ... @@ -148,5 +148,4 @@
148 148  
149 149  
150 150  * Try to shot the bootloader pin to GND and reset the device. So the device will runs in bootloader mode.
151 -
152 -* Or use (% style="color:blue" %)**AT+IREBOOT=7**(%%) to set the device to work in bootloader mode.
157 +* Or use AT+IREBOOT=7 to set the device to work in bootloader mode.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0