From version < 13.1 >
edited by Xiaoling
on 2022/05/27 08:49
To version < 16.3 >
edited by Xiaoling
on 2023/04/19 17:36
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,5 +1,5 @@
1 1  (% class="wikigeneratedid" %)
2 -**~ Contents:**
2 +**~ Table of Contents:**
3 3  
4 4  {{toc/}}
5 5  
... ... @@ -6,6 +6,7 @@
6 6  
7 7  = 1. Introduction =
8 8  
9 +
9 9  This article shows the firmware upgrade method and troubleshooting for the below models Dragino sensors.
10 10  
11 11  
... ... @@ -13,8 +13,10 @@
13 13  
14 14  == 2.1 LDS01/LWL01 ==
15 15  
17 +
16 16  [[Firmware Location>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Firmware/]]
17 17  
20 +
18 18  (((
19 19  Pin Mapping:
20 20  )))
... ... @@ -24,17 +24,19 @@
24 24  LDS01/LWL01 Pin Mapping
25 25  
26 26  
27 -DAP-Link Connection:
30 +**DAP-Link Connection:**
28 28  
29 29  [[image:image-20220527083959-2.png]]
30 30  
31 31  Connect DAP-Link
32 -
33 33  
36 +
34 34  == 2.2 LDS02/LWL02 ==
35 35  
36 -[[Firmware Location(same as LDS01)>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LDS01/Firmware/]]
37 37  
40 +[[Firmware Location(same as LDS01)>>https://www.dropbox.com/sh/9j35mnsxnz0y3ye/AACj5gHGOURGEHCpj-E861Mua?dl=0]]
41 +
42 +
38 38  (((
39 39  Pin Mapping:
40 40  )))
... ... @@ -44,6 +44,7 @@
44 44  LDS02/LDS02 v2.0 Pin Mapping
45 45  
46 46  
52 +
47 47  [[image:image-20220527084230-4.png]]
48 48  
49 49  LDS02/LDS02 v2.2 Pin Mapping
... ... @@ -51,8 +51,9 @@
51 51  
52 52  == 2.3 LHT52 ==
53 53  
54 -[[Firmware Location>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LHT52/firmware/]]
55 55  
61 +[[Firmware Location>>https://www.dropbox.com/sh/ayxhuf5dihtfu6c/AABRe_suu54EdTSFZIbD7t-ea?dl=0]]
62 +
56 56  [[image:image-20220527084401-5.png]]
57 57  
58 58  LHT52 Pin Mapping
... ... @@ -62,6 +62,7 @@
62 62  
63 63  == 3.1 Use DAP-Link and Connect to the Device as above photos ==
64 64  
72 +
65 65  We need to connect VDD,GND,SWCLK,SWDIO to DAP-Link.
66 66  
67 67  * Connection method:
... ... @@ -77,14 +77,16 @@
77 77  [[image:image-20220527084505-6.png]]
78 78  
79 79  
88 +
80 80  == 3.2 Install PSoCProgrammer 3.27.1 ==
81 81  
91 +
82 82  (((
83 83  Download Link: [[PSoCProgrammer3.27.1>>url:https://www.dragino.com/downloads/index.php?dir=tools/]]
84 84  )))
85 85  
86 86  (((
87 -And then use PSoCProgrammer to upgrade the firmware (must use this version: PSoCProgrammer3.27.1)
97 +And then use PSoCProgrammer to upgrade the firmware ( (% style="color:red" %) **must use this version: PSoCProgrammer3.27.1** (%%))
88 88  )))
89 89  
90 90  [[image:image-20220527084537-7.png]]
... ... @@ -92,11 +92,13 @@
92 92  
93 93  == 3.3 Download Sensor Firmware ==
94 94  
95 -Downlink sensor firmware to prepare the update
96 96  
106 +Downlink sensor firmware to prepare the update.
97 97  
108 +
98 98  == 3.4 Upgrade Firmware ==
99 99  
111 +
100 100  Open PSOC Programmer, select the default configuration, no need to modify
101 101  
102 102  [[image:image-20220527084612-8.png]]
... ... @@ -110,6 +110,7 @@
110 110  [[image:image-20220527084739-10.png||height="453" width="1034"]]
111 111  
112 112  
125 +
113 113  (((
114 114  Click the download icon, and the progress bar as shown in the figure below will appear. When PASS appears, it proves that the burning is successful.
115 115  )))
... ... @@ -116,19 +116,24 @@
116 116  
117 117  [[image:image-20220527084831-11.png]]
118 118  
119 -[[image:https://wiki.dragino.com/images/thumb/6/6f/Ppp14.png/600px-Ppp14.png||alt="Ppp14.png" height="338" width="600"]]
120 120  
133 +[[image:image-20220527084907-12.png]]
134 +
135 +
121 121  (((
122 -It is very important to press the reset button after the upgrade., this is to set the device to work in Low Power mode
137 +(% style="color:red" %)**It is very important to press the reset button after the upgrade., this is to set the device to work in Low Power mode.**
123 123  )))
124 124  
125 125  (((
126 -*If you change different LoRa Frequency Bands/Region, you need using AT+FDR command to restore factory data after program success
141 +(% style="color:red" %)**If you change different LoRa Frequency Bands/Region, you need using **(% style="color:blue" %)**AT+FDR **(% style="color:red" %)**command to restore factory data after program success.**
127 127  )))
128 128  
144 +
129 129  = 4. Trouble Shooting =
130 130  
131 131  == 4.1 Unable to detect upgrade ==
132 132  
149 +
133 133  * Try to shot the bootloader pin to GND and reset the device. So the device will runs in bootloader mode.
134 -* Or use AT+IREBOOT=7 to set the device to work in bootloader mode.
151 +
152 +* Or use (% style="color:blue" %)**AT+IREBOOT=7**(%%) to set the device to work in bootloader mode.
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved