Version 51.1 by Mengting Qiu on 2025/01/22 13:47

Hide last authors
Edwin Chen 8.1 1 **Table of Contents:**
2
3 {{toc/}}
4
5
Xiaoling 11.2 6
Xiaoling 10.2 7 = 1. Overview =
Edwin Chen 1.1 8
Xiaoling 10.2 9
Edwin Chen 23.1 10 There are some new models of Dragino sensors support OTA update via Private LoRa Protocol, (Even the sensor runs LoRaWAN protocol by default).
Edwin Chen 1.1 11
Edwin Chen 23.1 12 User can use the OTA update to update the configure file or firmware to the sensors.
Edwin Chen 1.1 13
Edwin Chen 23.1 14
Xiaoling 10.2 15 = 2. Support Models =
16
17
Edwin Chen 1.1 18 Here list the models that support OTA Update.
19
20 {{velocity}}
21 $xwiki.ssfx.use("js/xwiki/table/table.css")
22 $xwiki.jsfx.use("js/xwiki/table/tablefilterNsort.js", true)
23 {{/velocity}}
24
Xiaoling 32.2 25 (% border="1" cellspacing="5" class="doOddEven filterable grid sortable" id="tableid" style="background-color:#ffffff; width:670px" %)
26 (% class="sortHeader" %)|=(% style="width: 258px; background-color: rgb(217, 226, 243);" %)Models|=(% style="width: 158px; background-color: rgb(217, 226, 243);" %)Firmware Version|=(% style="width: 251px;background-color:#D9E2F3" %)Comments
27 |(% style="width:258px" %)RS485-LB/LS|(% style="width:158px" %)All firmware version|(% style="width:251px" %)
28 |(% style="width:258px" %)SN50v3-LB|(% style="width:158px" %)All firmware version|(% style="width:251px" %)
29 |(% style="width:258px" %)PS-LB-NA|(% style="width:158px" %)All firmware version|(% style="width:251px" %)
30 |(% style="width:258px" %)TS01-LB/LS|(% style="width:158px" %)All firmware version|(% style="width:251px" %)
31 |(% style="width:258px" %)CS01-LB|(% style="width:158px" %)All firmware version|(% style="width:251px" %)
32 |(% style="width:258px" %)AIS01-LB|(% style="width:158px" %)All firmware version|(% style="width:251px" %)
33 |(% style="width:258px" %)TC01-LB/ TC11-LB|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
34 |(% style="width:258px" %)LHT65N|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
35 |(% style="width:258px" %)LHT65N-PIR,LHT65N-E31F|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
36 |(% style="width:258px" %)D20-LB/D20S-LB/D22-LB/D23-LB|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
37 |(% style="width:258px" %)S31/S31B-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
38 |(% style="width:258px" %)AQS01-L|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
39 |(% style="width:258px" %)UV254-LB|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
40 |(% style="width:258px" %)SDI-12-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
41 |(% style="width:258px" %)SE01-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
42 |(% style="width:258px" %)PS-LB|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
43 |(% style="width:258px" %)SE02-LB|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
44 |(% style="width:258px" %)SPH01-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
45 |(% style="width:258px" %)LMS01-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
46 |(% style="width:258px" %)WL03A-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
47 |(% style="width:258px" %)DS03A-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
48 |(% style="width:258px" %)CPL03-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
49 |(% style="width:258px" %)SW3L-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
50 |(% style="width:258px" %)LCC01-LB|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
51 |(% style="width:258px" %)PS-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
52 |(% style="width:258px" %)LDS12-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
53 |(% style="width:258px" %)LDS40-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
54 |(% style="width:258px" %)DDS75-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
55 |(% style="width:258px" %)DDS45-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
56 |(% style="width:258px" %)DDS20-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
57 |(% style="width:258px" %)DDS04-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
58 |(% style="width:258px" %)MDS120-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
59 |(% style="width:258px" %)MDS200-LB/LS|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
60 |(% style="width:258px" %)DS20L|(% style="width:158px" %)All Firmware Version|(% style="width:251px" %)
Edwin Chen 2.1 61
Xiaoling 10.2 62 = 3. How to do OTA update =
63
64 == 3.1 Required Components ==
65
66
Mengting Qiu 45.1 67 * See FAQ 4.4 for how to update LA66 with the [[OTA Dongle Firmware>>https://www.dropbox.com/scl/fo/ztlw35a9xbkomu71u31im/AFhmjtEOaipfBAFrpMCoWrI/LoRaWAN%20End%20Node/LA66%20LoRaWAN%20module/Firmware/OTA_Firmware?dl=0&rlkey=ojjcsw927eaow01dgooldq3nu&subfolder_nav_tracking=1]].
Edwin Chen 29.1 68 * Software: [[OTA_Tool>>https://www.dropbox.com/scl/fo/9kqeqf6wmet10o9hgxuwa/h?rlkey=4ikrg6kg5v0yjxwhp0i37wrv7&dl=0]]. Only support Windows now
Edwin Chen 7.1 69
Edwin Chen 16.1 70 [[image:image-20230513120722-2.png||height="409" width="866"]]
Edwin Chen 7.1 71
Edwin Chen 14.1 72
Edwin Chen 23.1 73 == 3.2 OTA Update Firmware ==
Xiaoling 10.2 74
75
Edwin Chen 21.1 76 (% class="wikigeneratedid" %)
Mengting Qiu 24.1 77 (% class="mark text-uppercase" %)**Video Instruction:**(%%) ~-~- OTA Upgrade Firmware (via LoRa) of LoRaWAN Sensors**: [[https:~~/~~/youtu.be/SSvOqvBrwGg>>https://youtu.be/SSvOqvBrwGg]]**
Edwin Chen 21.1 78
79
Xiaoling 30.1 80 === (% style="color:blue" %)**Step1:**(%%) Plug LA66 USB to PC and run OTA_Tool. ===
Xiaoling 10.2 81
82
Mengting Qiu 40.1 83 [[image:image-20250121091115-1.png]]
Edwin Chen 7.1 84
85
Xiaoling 10.2 86 === (% style="color:blue" %)**Step2:**(%%) Set up OTA Tool ===
Edwin Chen 7.1 87
88
Mengting Qiu 27.1 89 * (% style="color:blue" %)**DevEUI**(%%): Input DevEUI of your sensor
Xiaoling 10.2 90
kai 31.1 91 * (% style="color:blue" %)**Password**(%%): Passord of your sensor**(Last eight bytes of APPSKEY)**
Xiaoling 10.2 92
93 * (% style="color:blue" %)**Port**(%%): Com port of LA66 USB
94
95 * (% style="color:blue" %)**LoRa_Freq**(%%): Choose the shipped frequency band of your sensor.
96
97 * (% style="color:blue" %)**Upload_File**(%%): The firmware to be upload to the sensor. make sure the firmware is with surfix _without_bootloader. For example: LHT65N_EU868_v1.5_without_bootloader.
98
Mengting Qiu 45.1 99 * (% style="color:blue" %)**DEUI_File**(%%): If customer has lots of sensors. He can also import the Dev EUI files and use droplist to choose the sensor to update. (If you did not ask us for a uniform update file, then you do not need to use this field, please ignore it.) Format is as below:
Xiaoling 10.2 100
Edwin Chen 7.1 101 [[image:image-20230114174640-3.png||height="130" width="1169"]]
102
103
Mengting Qiu 40.1 104 === (% style="color:blue" %)**Step3:**(%%) After re-plugging the LA66 USB, click "Start" in the OTA tool. ===
Edwin Chen 7.1 105
Xiaoling 10.2 106
Mengting Qiu 40.1 107 Upon re-plugging, the LA66 USB will reboot and broadcast the update process using the Dev EUI and passcode
Edwin Chen 7.1 108
109
Xiaoling 10.2 110 === (% style="color:blue" %)**Step4:** (%%)Press reset button on the end node, or re-activate the end node. ===
Edwin Chen 7.1 111
Mengting Qiu 40.1 112 When the OTA Tool displays “**LA66 is scanning for sensor Dev EUI ‘(% style="color:blue" %)DevEUI(%%)’. Please reset the sensor for connection and update**”, press and hold the ACT button on the terminal node for 5 seconds to perform a terminal node reset so that the OTA Tool can connect successfully.
Xiaoling 10.2 113
Mengting Qiu 40.1 114 [[image:image-20250121093705-3.png]]
115
Edwin Chen 7.1 116 In every reboot/ reactivate, the end node will check if there is update request. If end node gets the update request from LA66. End node will check if the Dev EUI and Password match. If match, End node will establish connection with LA66 USB for OTA update.
117
118
Xiaoling 10.2 119 === (% style="color:blue" %)**Step5:**(%%) Check result. ===
Edwin Chen 7.1 120
Xiaoling 10.2 121
Edwin Chen 7.1 122 Below shows the update successul result.
123
Mengting Qiu 40.1 124 [[image:image-20250121093834-4.png]]
Edwin Chen 7.1 125
126
Edwin Chen 14.1 127 = 4. FAQ =
Edwin Chen 7.1 128
Mengting Qiu 50.1 129 == 4.1 OTA_Tool supports two upgrade methods for -LB products. ==
Edwin Chen 14.1 130
131
Mengting Qiu 50.1 132 * For OTA_Tool, you can choose to use the OTA upgrade method, refer to the above upgrade steps in this user manual.
Xiaoling 20.2 133
Mengting Qiu 50.1 134 [[image:image-20250122104151-4.png||height="318" width="673"]]
Xiaoling 20.2 135
Mengting Qiu 50.1 136 * Of course, if you have a USB-TTL adapter, you can also choose to use the [[UART upgrade method>>https://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H3.2UpdateFirmware28Assumethedevicealreadyhaveabootloader29]] via OTA_Tool.
Xiaoling 20.2 137
Mengting Qiu 50.1 138 [[image:image-20250122104131-3.png||height="330" width="674"]]
Xiaoling 20.2 139
140
Edwin Chen 19.1 141 == 4.2 Where to find OTA Password? ==
142
Xiaoling 20.2 143
Edwin Chen 19.1 144 Each device has a shipped label with OTA Password which is 16 chars. like below. If user don't find this, please send us a photo for the device with Dev EUI to [[support@dragino.com>>mailto:support@dragino.com]] . and we will search the password for you.
145
146 [[image:image-20230519102907-2.png||height="286" width="580"]]
147
148
Edwin Chen 20.1 149 == 4.3 How about if i upgrade a crashed firmware via OTA update? ==
Edwin Chen 19.1 150
Edwin Chen 20.1 151
Xiaoling 20.2 152 OTA update is done via Bootloader and only change the firmware partition. So update a crash firmware via OTA update won't destroy bootloader and user can use OTA method to update again.
Edwin Chen 20.1 153
Xiaoling 20.2 154 (% style="color:red" %)**Here are notice:**
Edwin Chen 20.1 155
Xiaoling 20.2 156 ~1. OTA update frequency depend on the firmware frequency. If there is no frequency in the firmware. Bootloader will use EU868 as default frequency.
Edwin Chen 20.1 157
Xiaoling 20.2 158 2. OTA update require a reset or reactivate action. If the crash firmware doesn't have them work, user need to manuall push the physic reset button on the PCB or power off/on device.
159
160
Yi Wang 41.1 161 == 4.4 How to update the LA66 OTA Dongle via mobile phone? ==
Edwin Chen 35.1 162
Yi Wang 43.1 163 [[bootlooder>>url:https://wiki.dragino.com/xwiki/bin/download/Main/BLE%20Bluetooth%20Remote%20Configure/WebHome/LoRa_OTA_Bootloader_v1.4.bin?rev=1.1]] and [[OTA_firmware>>url:https://wiki.dragino.com/xwiki/bin/download/Main/BLE%20Bluetooth%20Remote%20Configure/WebHome/LA66%20OTA%20DONGLE%20v1.1.bin?rev=1.1]].
164
Yi Wang 42.1 165 Tool Download: [[Download link form Dropbox.>>https://www.dropbox.com/scl/fo/gyscmfn1s03oz3n8rif8w/AJW7JoMQsQ56dtlls2SNf9c?rlkey=3q2cxwriyzh26vuairx01yebc&st=be5jv92w&dl=0]] 
Yi Wang 41.1 166
Yi Wang 42.1 167 Operation instructions: [[Reference for operating procedures.>>https://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/#H3.1.3.3LA66upgrade]]
Yi Wang 41.1 168
Mengting Qiu 50.1 169
170
Yi Wang 41.1 171 == 4.5 Will OTA update effect the Local LoRaWAN Network. ==
172
Edwin Chen 35.1 173 User can configure the OTA_Frequency.txt file to change the Update frequency point so it won't conflict with the general LoRa Frequency. See below for the file as reference and explain. The OTA update also use a none-use SF (SF=5) which won't conflict with the current use SF.
174
175 (% class="mark" %)#Define the OTA frequency use for OTA.
176 #End Node has FRE1 and SF=5. So don't change FRE1 settings
177 #FRE2 include several frequencies point.
178 #PC first use FRE1 to create connection to end node, then use one of FRE2 frequencies to process downlink.
179
180 (% class="mark" %)#Format:
181 #Frequency Band;FRE1;FRE2
182 EU868;869.0;868.7,868.9
183 IN865;866.9;865.1,865.3
184 KZ865;866.5;866.1,866.3
185 KR920;921.7;921.3,921.5
186 MA869;870.5;870.7,870.9
187 US915;923.1;923.7,924.1
188 CN470;505.5;605.7,505.9
189 AU915;923.7;924.7,925.5
190 AS923;923.5;923.3,923.7
191 AS923-2;921.2;921.8,922.0
192 AS923-3;916.4;917.0,917.2
193 AS923-4;917.1;917.6,917.8
194 EU433;434.5;433.9,434.1
195 RU864;869.3;869.5,869.7
196
197
Mengting Qiu 50.1 198 == 4.6 The old version LA66 is different from the new version LA66. Can OTA_Tool be used for both versions? ==
199
200
201 The most obvious hardware difference between LA66 V1 and LA66v2 when burning is the presence of a "RESET "button, and the RESET operation is only for LA66 without a boot loader, you can refer to this link to learn how to upgrade LA66 without a boot loader:[[LA66 USB LoRaWAN Adapter User Manual - DRAGINO>>url:https://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20USB%20LoRaWAN%20Adapter%20User%20Manual/#H1.10.2Updatemethod:A0ForLA66withoutbootloader]]
202
203 In summary, as long as your LA66 has a boot loader, either LA66 V1 or LA66 V2 can use OTA_Tool.
204
205
206 == 4.7 Why can't LA66 burn its own working firmware after it is used for OTA upgrade of -LB products? ==
207
208
209 We are sorry for the inadequacy of LA66 for OTA updates in the past.
210
211 * In the past, the download address of LA66 OTA DONGLE V1.0 was (% style="color:blue" %)**0x08000000**(%%), and the address of the bootloader that existed by default when the LA66 was shipped was also (% style="color:blue" %)**0x08000000**(%%).
212
213 Therefore, when you burn OTA_Firmwar v1.0 (LA66 OTA DONGLE v1.0) for the LA66 in order to use the LA66‘s ability to perform OTA upgrades for -LB products, the LA66’s bootloader is overridden.
214
215 So if you need to switch back to the LA66's working firmware, you'll need to refer to this [[link>>https://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20USB%20LoRaWAN%20Adapter%20User%20Manual/#H1.10.2Updatemethod:A0ForLA66withoutbootloader]] for instructions to burn firmware with a bootloader for the LA66.
216
217 [[image:image-20250122113225-5.png||height="336" width="798"]]
218
219 * For the new version of LA66 OTA DONGLE V1.1, we have changed the supported download address to (% style="color:blue" %)**0x0800D000**(%%) the same as other working firmware addresses, so you can simply use OTA_Tool to burn LA66 OTA DONGLE V1.1 and LA66 working firmware for LA66.
220
221
Edwin Chen 14.1 222 = 5. OTA Tool Known Bug: =
223
224
Xiaoling 10.2 225 ~1. If user click "(% style="color:blue" %)**Start**"(%%) but there is issue during update. User may need to close and open the tool again.
Edwin Chen 7.1 226