Changes for page OTA Update Firmware/Configure for Sensors
Last modified by Mengting Qiu on 2025/06/17 09:18
From version 53.1
edited by Mengting Qiu
on 2025/01/22 14:14
on 2025/01/22 14:14
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 6 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. ting1 +XWiki.wy - Content
-
... ... @@ -64,7 +64,8 @@ 64 64 == 3.1 Required Components == 65 65 66 66 67 -* See FAQ 4.4 for how to update LA66 with the [[OTA Dongle Firmware>>https://www.dropbox.com/scl/fo/ztlw35a9xbkomu71u31im/AFhmjtEOaipfBAFrpMCoWrI/LoRaWAN%20End%20Node/LA66%20LoRaWAN%20module/Firmware/OTA_Firmware?dl=0&rlkey=ojjcsw927eaow01dgooldq3nu&subfolder_nav_tracking=1]]. 67 +* See FAQ 4.4 for how to update LA66 with the OTA Dongle Firmware. 68 + 68 68 * Software: [[OTA_Tool>>https://www.dropbox.com/scl/fo/9kqeqf6wmet10o9hgxuwa/h?rlkey=4ikrg6kg5v0yjxwhp0i37wrv7&dl=0]]. Only support Windows now 69 69 70 70 [[image:image-20230513120722-2.png||height="409" width="866"]] ... ... @@ -96,7 +96,7 @@ 96 96 97 97 * (% style="color:blue" %)**Upload_File**(%%): The firmware to be upload to the sensor. make sure the firmware is with surfix _without_bootloader. For example: LHT65N_EU868_v1.5_without_bootloader. 98 98 99 -* (% style="color:blue" %)**DEUI_File**(%%): If customer has lots of sensors. He can also import the Dev EUI files and use droplist to choose the sensor to update. (If you did not ask us for a uniform update file, then you do not need to use this field, please ignore it.)Format is as below:100 +* (% style="color:blue" %)**DEUI_File**(%%): If customer has lots of sensors. He can also import the Dev EUI files and use droplist to choose the sensor to update. Format is as below: 100 100 101 101 [[image:image-20230114174640-3.png||height="130" width="1169"]] 102 102 ... ... @@ -124,20 +124,31 @@ 124 124 [[image:image-20250121093834-4.png]] 125 125 126 126 128 +== 3.3 OTA Update Configure == 129 + 130 + 131 +(% class="mark text-uppercase" %)**Video Instruction:**(%%) ~-~- OTA Upgrade Configure (via LoRa) of LoRaWAN Sensors**: [[https:~~/~~/youtu.be/5XedoNVkbQQ>>https://youtu.be/5XedoNVkbQQ]]** 132 + 133 +OTA Update Configure is good for batch update configure in same type of sensors. 134 + 135 + 127 127 = 4. FAQ = 128 128 129 -== 4.1 OTA_Toolsupports twoupgrademethodsfor-LBproducts.==138 +== 4.1 Can i use other devices to connect to PC if i don't have LA66 USB? == 130 130 131 131 132 - *ForOTA_Tool, youcanchoosetouse theOTA upgrade method,refertothe aboveupgrade stepsinthisusermanual.141 +If user doesn't have LA66 USB Adapter, they can still use other Dragino Device to connect to PC for OTA update. 133 133 134 - [[image:image-20250122104151-4.png||height="318"width="673"]]143 +(% style="color:blue" %)**Steps:** 135 135 136 -* Ofcourse,if youhavea USB-TTL adapter,youcanalso choosetousethe[[UARTupgrademethod>>https://wiki.dragino.com/xwiki/bin/view/Main/UART%20Access%20for%20LoRa%20ST%20v4%20base%20model/#H3.2UpdateFirmware28Assumethedevicealreadyhaveabootloader29]]viaOTA_Tool.145 +* Find the suitable mode which base on LA66 chip ( All LoRaWAN model with LB or LS suffix , such as SN50v3-LB) 137 137 138 - [[image:image-20250122104131-3.png||height="330"width="674"]]147 +* Update the LA66 USB OTA firmware to the device. 139 139 149 +* Connect the device to PC via UART interface. 140 140 151 +* Make sure power off or update the firmware back to original firmware , because the LA66 USB OTA fimware is not low power consumption firmware. it will consume the battery very fast. 152 + 141 141 == 4.2 Where to find OTA Password? == 142 142 143 143 ... ... @@ -158,24 +158,14 @@ 158 158 2. OTA update require a reset or reactivate action. If the crash firmware doesn't have them work, user need to manuall push the physic reset button on the PCB or power off/on device. 159 159 160 160 161 -== 4.4 How to update the LA66 OTA Dongle V1.1via mobile phone? ==173 +== 4.4 How to update the LA66 OTA Dongle via mobile phone? == 162 162 175 +Tool Download:1. [[Temporary Downloads.>>attach:Main.BLE Bluetooth Remote Configure.WebHome@Device_Tool_1.4.apk]] 163 163 164 -[[ image:image-20250122113225-5.png||height="259"width="615"]]177 + 2. [[Download link.>>https://www.dropbox.com/scl/fo/gyscmfn1s03oz3n8rif8w/AJW7JoMQsQ56dtlls2SNf9c?rlkey=3q2cxwriyzh26vuairx01yebc&st=be5jv92w&dl=0]] Currently, version 1.4 is not added to Dropbox.It is recommended to use temporary downloads. 165 165 166 - * If you haveneverdownloaded LA66 OTA DongleV1.0to yourLA66, youan directlyupgradethe LA66 OTA DongleV1.1program from yourphoneusingthefollowingmethod.179 +Operation instructions:[[Reference for operating procedures>>https://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/#H3.1.3.3LA66upgrade]] 167 167 168 -[[bootlooder>>url:https://wiki.dragino.com/xwiki/bin/download/Main/BLE%20Bluetooth%20Remote%20Configure/WebHome/LoRa_OTA_Bootloader_v1.4.bin?rev=1.1]] and [[OTA_firmware>>url:https://wiki.dragino.com/xwiki/bin/download/Main/BLE%20Bluetooth%20Remote%20Configure/WebHome/LA66%20OTA%20DONGLE%20v1.1.bin?rev=1.1]]. 169 - 170 -Tool Download: [[Download link form Dropbox.>>https://www.dropbox.com/scl/fo/gyscmfn1s03oz3n8rif8w/AJW7JoMQsQ56dtlls2SNf9c?rlkey=3q2cxwriyzh26vuairx01yebc&st=be5jv92w&dl=0]] 171 - 172 -Operation instructions: [[Reference for operating procedures.>>https://wiki.dragino.com/xwiki/bin/view/Main/BLE%20Bluetooth%20Remote%20Configure/#H3.1.3.3LA66upgrade]] 173 - 174 -* If you have burned LA66 OTA DONGLE V1.0 for your LA66 according to previously existing instructions. Then you need to re-burn your LA66 boot loader first: [[LA66 USB LoRaWAN Adapter User Manual - DRAGINO>>url:https://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20USB%20LoRaWAN%20Adapter%20User%20Manual/#H1.10.2Updatemethod:A0ForLA66withoutbootloader]] 175 - 176 - Please refer to FAQ 4.7 for detailed reasons. 177 - 178 - 179 179 == 4.5 Will OTA update effect the Local LoRaWAN Network. == 180 180 181 181 User can configure the OTA_Frequency.txt file to change the Update frequency point so it won't conflict with the general LoRa Frequency. See below for the file as reference and explain. The OTA update also use a none-use SF (SF=5) which won't conflict with the current use SF. ... ... @@ -203,31 +203,6 @@ 203 203 RU864;869.3;869.5,869.7 204 204 205 205 206 -== 4.6 The old version LA66 is different from the new version LA66. Can OTA_Tool be used for both versions? == 207 - 208 - 209 -The most obvious hardware difference between LA66 V1 and LA66v2 when burning is the presence of a "RESET "button, and the RESET operation is only for LA66 without a boot loader, you can refer to this link to learn how to upgrade LA66 without a boot loader:[[LA66 USB LoRaWAN Adapter User Manual - DRAGINO>>url:https://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20USB%20LoRaWAN%20Adapter%20User%20Manual/#H1.10.2Updatemethod:A0ForLA66withoutbootloader]] 210 - 211 -[[image:image-20250122134752-6.png||height="288" width="543"]] 212 - 213 -In summary, as long as your LA66 has a boot loader, either LA66 V1 or LA66 V2 can use OTA_Tool. 214 - 215 - 216 -== 4.7 Why can't LA66 burn its own working firmware after it is used for OTA upgrade of -LB products? == 217 - 218 - 219 -We are sorry for the inadequacy of LA66 for OTA updates in the past. 220 - 221 -* In the past, the download address of LA66 OTA DONGLE V1.0 was (% style="color:blue" %)**0x08000000**(%%), and the address of the bootloader that existed by default when the LA66 was shipped was also (% style="color:blue" %)**0x08000000**(%%). 222 - 223 -Therefore, when you burn OTA_Firmwar v1.0 (LA66 OTA DONGLE v1.0) for the LA66 in order to use the LA66‘s ability to perform OTA upgrades for -LB products, the LA66’s bootloader is overridden. 224 - 225 -So if you need to switch back to the LA66's working firmware, you'll need to refer to this [[link>>https://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LA66%20USB%20LoRaWAN%20Adapter%20User%20Manual/#H1.10.2Updatemethod:A0ForLA66withoutbootloader]] for instructions to burn firmware with a bootloader for the LA66. 226 - 227 -[[image:image-20250122113225-5.png||height="336" width="798"]] 228 - 229 -* For the new version of LA66 OTA DONGLE V1.1, we have changed the supported download address to (% style="color:blue" %)**0x0800D000**(%%) the same as other working firmware addresses, so you can simply use OTA_Tool to burn LA66 OTA DONGLE V1.1 and LA66 working firmware for LA66. 230 - 231 231 = 5. OTA Tool Known Bug: = 232 232 233 233
- image-20250122101944-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -34.2 KB - Content
- image-20250122103630-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -47.0 KB - Content
- image-20250122104131-3.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -21.7 KB - Content
- image-20250122104151-4.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.3 KB - Content
- image-20250122113225-5.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -27.0 KB - Content
- image-20250122134752-6.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.ting - Size
-
... ... @@ -1,1 +1,0 @@ 1 -3.3 MB - Content