Last modified by Mengting Qiu on 2025/06/17 09:18

From version 13.1
edited by Edwin Chen
on 2023/05/13 12:02
Change comment: Uploaded new attachment "image-20230513115907-1.png", version {1}
To version 20.1
edited by Edwin Chen
on 2023/05/20 10:32
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -31,7 +31,6 @@
31 31  )))|(% style="width:222px" %)All firmware version|(% style="width:251px" %)
32 32  |(% style="width:193px" %)S31-LB, S31B-LB|(% style="width:222px" %)All firmware version|(% style="width:251px" %)
33 33  
34 -
35 35  = 3. How to do OTA update =
36 36  
37 37  == 3.1 Required Components ==
... ... @@ -40,7 +40,9 @@
40 40  * Hardware: [[LA66 USB>>doc:Main.User Manual for LoRaWAN End Nodes.LA66 USB LoRaWAN Adapter User Manual.WebHome]] with [[OTA_firmware>>https://www.dropbox.com/sh/4qnjreg1esxu16i/AADbRjW_tuBP3IIkmf11nSoma?dl=0]] installed.
41 41  * Software: [[OTA_Tool>>https://www.dropbox.com/sh/4qnjreg1esxu16i/AADbRjW_tuBP3IIkmf11nSoma?dl=0]]. Only support Windows now
42 42  
42 +[[image:image-20230513120722-2.png||height="409" width="866"]]
43 43  
44 +
44 44  == 3.2 Update Steps ==
45 45  
46 46  
... ... @@ -88,9 +88,37 @@
88 88  [[image:image-20230114174134-2.png]]
89 89  
90 90  
91 -= 4. OTA Tool Known Bug: =
92 92  
93 += 4. FAQ =
93 93  
95 +== 4.1 Can i use other devices to connect to PC if i don't have LA66 USB? ==
96 +
97 +If user doesn't have LA66 USB Adapter, they can still use other Dragino Device to connect to PC for OTA update. Steps:
98 +
99 +* Find the suitable mode which base on LA66 chip ( All LoRaWAN model with LB or LS suffix , such as SN50v3-LB)
100 +* Update the LA66 USB OTA firmware to the device.
101 +* Connect the device to PC via UART interface.
102 +* Make sure power off or update the firmware back to original firmware , because the LA66 USB OTA fimware is not low power consumption firmware. it will consume the battery very fast.
103 +
104 +== 4.2 Where to find OTA Password? ==
105 +
106 +Each device has a shipped label with OTA Password which is 16 chars. like below. If user don't find this, please send us a photo for the device with Dev EUI to [[support@dragino.com>>mailto:support@dragino.com]] . and we will search the password for you.
107 +
108 +[[image:image-20230519102907-2.png||height="286" width="580"]]
109 +
110 +
111 +== 4.3 How about if i upgrade a crashed firmware via OTA update? ==
112 +
113 +OTA update is done via Bootloader and only change the firmware partition. So update a crash firmware via OTA update won't destroy bootloader and user can use OTA method to update again. Here are notice:
114 +
115 +1. OTA update frequency depend on the firmware frequency. If there is no frequency in the firmware. Bootloader will use EU868 as default frequency.
116 +1. OTA update require a reset or reactivate action. If the crash firmware doesn't have them work, user need to manuall push the physic reset button on the PCB or power off/on device.
117 +
118 +
119 +
120 += 5. OTA Tool Known Bug: =
121 +
122 +
94 94  ~1. If user click "(% style="color:blue" %)**Start**"(%%) but there is issue during update. User may need to close and open the tool again.
95 95  
96 96  
image-20230513120722-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +170.2 KB
Content
image-20230519102840-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +29.9 KB
Content
image-20230519102907-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +138.9 KB
Content