<
From version < 9.1 >
edited by Xiaoling
on 2022/05/30 10:38
To version < 16.1 >
edited by Edwin Chen
on 2023/12/07 09:47
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -1,5 +1,5 @@
1 1  (% class="wikigeneratedid" id="HEndDeviceFrequencyBand" %)
2 - **Contents:**
2 + **Table of** **Contents:**
3 3  
4 4  {{toc/}}
5 5  
... ... @@ -8,31 +8,31 @@
8 8  
9 9  = 1. Introduction =
10 10  
11 +
11 11  This page list the default frequency band for Dragino End Devices. The frequency bands are base on TTN Frequency Bands. User can modify upgrade firmware to support different frequency band or use AT Command to change the sub band in some frequency bands.
12 12  
13 13  * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]]
14 14  * Frequency Bands vs Country List : Page 11 of [[LoRaWAN Regional Parameters RP2-1.0.3>>url:https://resources.lora-alliance.org/technical-specifications/rp2-1-0-3-lorawan-regional-parameters]]
15 15  
16 -
17 17  = 2. OTAA Join Behaviour =
18 18  
19 -For 005 LoRaWAN stack: to save battery, once boot, device will make first make 200 tries for OTAA Join, the time period of two Join Requests will depends on the DR and the airtime requirement. After this 200 Join finish, device will send a join request every 20 minutes. If device reboot, it will do above loop again.
20 20  
20 +Since 005 LoRaWAN stack: to save battery, once boot, device will first make 200 tries for OTAA Join, the time period of two Join Requests will depends on the DR and the airtime requirement. After this 200 Join finish, device will send a join request every 20 minutes. If device reboot, it will do above loop again.
21 +
21 21  (((
22 -For 005 LoRaWAN Stack:
23 +Since 005 LoRaWAN Stack:
23 23  )))
24 24  
25 25  * EU868 OTAA Join DR select. SF7->SF8->SF9->SF10->SF11->SF12; Each 3 attempts and then loop
26 -* US915 and AU915 OTAA Join procedure,. End node by default will use all 72 channels to join and it will be set to use the proper sub-band after Join success
27 +* US915 and AU915 OTAA Join procedure,. End node by default will use all 72 channels (All sub-bands) to join and it will be set to use the proper sub-band after Join success
27 27  
28 -
29 29  = 3. Default Frequency Bands =
30 30  
31 -
32 32  == 3.1 AS923 ==
33 33  
34 34  === 3.1.1 Notice for AS923 Frequency Bands ===
35 35  
35 +
36 36  (((
37 37  Since [[RP002-1.0.1LoRaWAN Regional Parameters>>url:https://lora-alliance.org/sites/default/files/2020-02/rp_2-1.0.1.pdf]], AS923 include three different default settings for different countries: AS923-1, AS923-2 and AS923-3.
38 38  )))
... ... @@ -44,6 +44,8 @@
44 44  
45 45  === 3.1.2 AS920-923 & AS923-925 : AS923-1 (AS923) ===
46 46  
47 +
48 +* **Countries**: Malaysia,
47 47  * Default Uplink channel:
48 48  ** 923.2 - SF7BW125 to SF10BW125
49 49  ** 923.4 - SF7BW125 to SF10BW125
... ... @@ -69,10 +69,9 @@
69 69  ** Uplink channels 1-8 (RX1)
70 70  ** 923.2 - SF10BW125 (RX2)
71 71  
72 -
73 -
74 74  === 3.1.3 AS923-2 ===
75 75  
76 +
76 76  * Default Uplink channel:
77 77  ** 921.4 - SF7BW125 to SF10BW125
78 78  ** 921.6 - SF7BW125 to SF10BW125
... ... @@ -83,10 +83,9 @@
83 83  ** Uplink channels 1-8 (RX1)
84 84  ** 921.4 - SF10BW125 (RX2)
85 85  
86 -
87 -
88 88  === 3.1.4 AS923-3 ===
89 89  
89 +
90 90  * Default Uplink channel:
91 91  ** 916.6 - SF7BW125 to SF10BW125
92 92  ** 916.8 - SF7BW125 to SF10BW125
... ... @@ -97,10 +97,9 @@
97 97  ** Uplink channels 1-8 (RX1)
98 98  ** 916.6 - SF10BW125 (RX2)
99 99  
100 -
101 -
102 102  === 3.1.5 AS923-4 ===
103 103  
102 +
104 104  * Countries : Israel
105 105  * Default Uplink channel:
106 106  ** 917.3 - SF7BW125 to SF10BW125
... ... @@ -111,10 +111,9 @@
111 111  ** Uplink channels 1-8 (RX1)
112 112  ** 917.3 - SF10BW125 (RX2)
113 113  
114 -
115 -
116 116  == 3.2 AU915-928(AU915) ==
117 117  
115 +
118 118  **Before [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]** , Default use CHE=2
119 119  
120 120  * Uplink:
... ... @@ -156,13 +156,15 @@
156 156  Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
157 157  )))
158 158  * (((
159 -Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
157 +Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
160 160  
159 +
161 161  
162 162  )))
163 163  
164 164  == 3.3 CN470-510 (CN470) ==
165 165  
165 +
166 166  Used in China, Default use CHE=1
167 167  
168 168  * Uplink:
... ... @@ -186,10 +186,9 @@
186 186  ** 508.1 - SF7BW125 to SF12BW125
187 187  ** 505.3 - SF12BW125 (RX2 downlink only)
188 188  
189 -
190 -
191 191  == 3.4 EU863-870 (EU868) ==
192 192  
191 +
193 193  * Uplink:
194 194  ** 868.1 - SF7BW125 to SF12BW125
195 195  ** 868.3 - SF7BW125 to SF12BW125 and SF7BW250
... ... @@ -210,6 +210,7 @@
210 210  
211 211  == 3.5 IN865-867 (IN865) ==
212 212  
212 +
213 213  * Uplink:
214 214  ** 865.0625 - SF7BW125 to SF12BW125
215 215  ** 865.4025 - SF7BW125 to SF12BW125
... ... @@ -219,10 +219,20 @@
219 219  ** Uplink channels 1-3 (RX1)
220 220  ** 866.550 - SF10BW125 (RX2)
221 221  
222 +Gateway has below eight channels in IN865 bands.
222 222  
224 +* 865.0625 - SF7BW125 to SF12BW125
225 +* 865.4025 - SF7BW125 to SF12BW125
226 +* 865.6025 - SF7BW125 to SF12BW125
227 +* 865.9850 - SF7BW125 to SF12BW125
228 +* 866.1850 - SF7BW125 to SF12BW125
229 +* 866.3850 - SF7BW125 to SF12BW125
230 +* 866.5850 - SF7BW125 to SF12BW125
231 +* 866.7850 - SF7BW125 to SF12BW125
223 223  
224 224  == 3.6 KZ865 ==
225 225  
235 +
226 226  * Uplink ~-~- 125Khz , DR0 - DR5
227 227  ** 865.1
228 228  ** 865.2
... ... @@ -234,10 +234,9 @@
234 234  ** The RX1 receive window uses the same channel as the preceding uplink.
235 235  ** The RX2 receive window uses a fixed frequency and data rate. The default parameters are 866.7MHz / DR0 (SF12, 125 kHz)​
236 236  
237 -
238 -
239 239  == 3.7 KR920-923 (KR920) ==
240 240  
249 +
241 241  * Default channel:
242 242  ** 922.1 - SF7BW125 to SF12BW125
243 243  ** 922.3 - SF7BW125 to SF12BW125
... ... @@ -256,10 +256,9 @@
256 256  ** Uplink channels 1-7(RX1)
257 257  ** 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
258 258  
259 -
260 -
261 261  == 3.8 MA869 ==
262 262  
270 +
263 263   Country: Morroco
264 264  
265 265  * Uplink:
... ... @@ -277,15 +277,15 @@
277 277  ** Uplink channels 1-9 (RX1)
278 278  ** 869.525 - SF12BW125 (RX2 downlink only)
279 279  
280 -
281 -
282 282  == 3.9 US902-928 (US915) ==
283 283  
290 +
284 284  Used in USA, Canada and South America.
285 285  
286 286  
287 287  === 3.9.1 Before [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]. ===
288 288  
296 +
289 289  Default use CHE=2, Subband 2
290 290  
291 291  * Uplink:
... ... @@ -311,18 +311,15 @@
311 311  
312 312  === 3.9.2 Latest firmware, Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]] ===
313 313  
322 +
314 314  (((
315 315  There is an issue if the end node is fixed at sub-band2. The sensor won't be able to register to other sub-band and can only work for the LoRaWAN server use sub-band2 , such as TTN. To solve this, the user needs to use a USB-TTL adapter to connect to the end node to manually set the sub-band which is very inconvenient.
316 316  )))
317 317  
318 318  (((
319 -
328 +So since **Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]**, we have improved this, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join. In this case, the end node can support LoRaWAN servers with different subbands. To make sure the end node will only transmit the proper sub-band after OTAA Joined successfully, the end node will:
320 320  )))
321 321  
322 -(((
323 -So since **Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]**, we have improved this, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join, In this case, In this case, the end node can support LoRaWAN servers with different subbands. To make sure the end node will only transmit the proper sub-band after OTAA Joined successfully, the end node will:
324 -)))
325 -
326 326  * (((
327 327  Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that subband
328 328  )))
... ... @@ -329,10 +329,40 @@
329 329  * (((
330 330  Use the Join successful sub-band if the server doesn't include subband info in the OTAA Join Accept message ( TTN v2 doesn't include)
331 331  
337 +
332 332  
333 333  )))
334 334  
335 335  = 4. Frequency Bands for different server =
336 336  
343 +
337 337  * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]]
338 338  * Loriot [[https:~~/~~/docs.loriot.io/display/LNS/Regional+Frequency+Plans>>url:https://docs.loriot.io/display/LNS/Regional+Frequency+Plans]]
346 +
347 += 5. Subband Related questiones in US915, AU915, CN470 bands. =
348 +
349 +
350 +Frequency band US915, AU915 and CN470 supports totally 72 frequency in 8 sub-bands, Normally Gateway only support 8 channels ( one subband). So how does the gateway and end nodes work in such frequency?
351 +
352 +
353 +== 5.1 Set Subband in Gateway. ==
354 +
355 +
356 +* If Gateway choose (% style="color:blue" %)**Semtech UDP packet**(%%) forwarder to Connect to LoRaWAN server. User need to manually set the match Subband in the gateway web UI.
357 +
358 +* If Gateway choose (% style="color:blue" %)**Basic Station Mode**(%%) to connect to the LoRaWAN server. User can set the subband in the Server side and gateway will the correct subband from server. no need to set this in gateway. AWS-IoT, TTN, ChirpStack all supports Basic Station Connection.
359 +
360 +== 5.2 Set Subband in End Node ==
361 +
362 +
363 +* In early End Node firmware, it is pre-set to subband 2 , user need to manually set to proper subband if they don;t use subband 2.
364 +
365 +* In new end node firmware , it supports all sub-bands, and will swtich to the proper subband after OTAA join. So user can use the end node with all sub-band.
366 +
367 +Reference: [[How it affects the OTAA Join when end node is set to support all subbands>>http://wiki.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H13.WhyittakeslongertimeforOTAAjoinedinUS9152FCN4702FAU915band3F]]?
368 +
369 +
370 +
371 +
372 +
373 +
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0