<
From version < 17.1 >
edited by Edwin Chen
on 2024/02/15 00:10
To version < 11.3 >
edited by Xiaoling
on 2022/05/31 08:57
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -1,5 +1,5 @@
1 1  (% class="wikigeneratedid" id="HEndDeviceFrequencyBand" %)
2 - **Table of** **Contents:**
2 + **Contents:**
3 3  
4 4  {{toc/}}
5 5  
... ... @@ -8,32 +8,31 @@
8 8  
9 9  = 1. Introduction =
10 10  
11 -
12 12  This page list the default frequency band for Dragino End Devices. The frequency bands are base on TTN Frequency Bands. User can modify upgrade firmware to support different frequency band or use AT Command to change the sub band in some frequency bands.
13 13  
14 14  * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]]
15 15  * Frequency Bands vs Country List : Page 11 of [[LoRaWAN Regional Parameters RP2-1.0.3>>url:https://resources.lora-alliance.org/technical-specifications/rp2-1-0-3-lorawan-regional-parameters]]
16 16  
16 +
17 17  = 2. OTAA Join Behaviour =
18 18  
19 -Since 005 LoRaWAN stack: One device boot or reset, it will
19 +For 005 LoRaWAN stack: to save battery, once boot, device will make first make 200 tries for OTAA Join, the time period of two Join Requests will depends on the DR and the airtime requirement. After this 200 Join finish, device will send a join request every 20 minutes. If device reboot, it will do above loop again.
20 20  
21 -* First make 200 Join Requestes for OTAA Join, the interval of two Join Requests will depends on the DR and the airtime requirement.
22 -* After 200 Join Requestes, if end node still not join successful, to save battery life, it will keep sending join request at the default uplink interval ( 20 minutes) .
23 -* If device reboot, it will do above loop again.
21 +(((
22 +For 005 LoRaWAN Stack:
23 +)))
24 24  
25 -Since 005 LoRaWAN Stack:
25 +* EU868 OTAA Join DR select. SF7->SF8->SF9->SF10->SF11->SF12; Each 3 attempts and then loop
26 +* US915 and AU915 OTAA Join procedure,. End node by default will use all 72 channels to join and it will be set to use the proper sub-band after Join success
26 26  
27 -* **EU868 OTAA Join DR Logic**. SF7->SF8->SF9->SF10->SF11->SF12; Each SF will make 3 attempts and then loop
28 -* **US915 and AU915 OTAA Join procedure**,. End node by default will use all 72 channels (All sub-bands) to join and it will be set to use the proper sub-band after Join success
29 29  
30 30  = 3. Default Frequency Bands =
31 31  
31 +
32 32  == 3.1 AS923 ==
33 33  
34 34  === 3.1.1 Notice for AS923 Frequency Bands ===
35 35  
36 -
37 37  (((
38 38  Since [[RP002-1.0.1LoRaWAN Regional Parameters>>url:https://lora-alliance.org/sites/default/files/2020-02/rp_2-1.0.1.pdf]], AS923 include three different default settings for different countries: AS923-1, AS923-2 and AS923-3.
39 39  )))
... ... @@ -45,8 +45,6 @@
45 45  
46 46  === 3.1.2 AS920-923 & AS923-925 : AS923-1 (AS923) ===
47 47  
48 -
49 -* **Countries**: Malaysia,
50 50  * Default Uplink channel:
51 51  ** 923.2 - SF7BW125 to SF10BW125
52 52  ** 923.4 - SF7BW125 to SF10BW125
... ... @@ -72,9 +72,9 @@
72 72  ** Uplink channels 1-8 (RX1)
73 73  ** 923.2 - SF10BW125 (RX2)
74 74  
72 +
75 75  === 3.1.3 AS923-2 ===
76 76  
77 -
78 78  * Default Uplink channel:
79 79  ** 921.4 - SF7BW125 to SF10BW125
80 80  ** 921.6 - SF7BW125 to SF10BW125
... ... @@ -87,7 +87,6 @@
87 87  
88 88  === 3.1.4 AS923-3 ===
89 89  
90 -
91 91  * Default Uplink channel:
92 92  ** 916.6 - SF7BW125 to SF10BW125
93 93  ** 916.8 - SF7BW125 to SF10BW125
... ... @@ -100,7 +100,6 @@
100 100  
101 101  === 3.1.5 AS923-4 ===
102 102  
103 -
104 104  * Countries : Israel
105 105  * Default Uplink channel:
106 106  ** 917.3 - SF7BW125 to SF10BW125
... ... @@ -113,7 +113,6 @@
113 113  
114 114  == 3.2 AU915-928(AU915) ==
115 115  
116 -
117 117  **Before [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]** , Default use CHE=2
118 118  
119 119  * Uplink:
... ... @@ -155,15 +155,13 @@
155 155  Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
156 156  )))
157 157  * (((
158 -Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
152 +Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
159 159  
160 -
161 161  
162 162  )))
163 163  
164 164  == 3.3 CN470-510 (CN470) ==
165 165  
166 -
167 167  Used in China, Default use CHE=1
168 168  
169 169  * Uplink:
... ... @@ -187,9 +187,9 @@
187 187  ** 508.1 - SF7BW125 to SF12BW125
188 188  ** 505.3 - SF12BW125 (RX2 downlink only)
189 189  
182 +
190 190  == 3.4 EU863-870 (EU868) ==
191 191  
192 -
193 193  * Uplink:
194 194  ** 868.1 - SF7BW125 to SF12BW125
195 195  ** 868.3 - SF7BW125 to SF12BW125 and SF7BW250
... ... @@ -210,7 +210,6 @@
210 210  
211 211  == 3.5 IN865-867 (IN865) ==
212 212  
213 -
214 214  * Uplink:
215 215  ** 865.0625 - SF7BW125 to SF12BW125
216 216  ** 865.4025 - SF7BW125 to SF12BW125
... ... @@ -220,20 +220,9 @@
220 220  ** Uplink channels 1-3 (RX1)
221 221  ** 866.550 - SF10BW125 (RX2)
222 222  
223 -Gateway has below eight channels in IN865 bands.
224 224  
225 -* 865.0625 - SF7BW125 to SF12BW125
226 -* 865.4025 - SF7BW125 to SF12BW125
227 -* 865.6025 - SF7BW125 to SF12BW125
228 -* 865.9850 - SF7BW125 to SF12BW125
229 -* 866.1850 - SF7BW125 to SF12BW125
230 -* 866.3850 - SF7BW125 to SF12BW125
231 -* 866.5850 - SF7BW125 to SF12BW125
232 -* 866.7850 - SF7BW125 to SF12BW125
233 -
234 234  == 3.6 KZ865 ==
235 235  
236 -
237 237  * Uplink ~-~- 125Khz , DR0 - DR5
238 238  ** 865.1
239 239  ** 865.2
... ... @@ -245,9 +245,9 @@
245 245  ** The RX1 receive window uses the same channel as the preceding uplink.
246 246  ** The RX2 receive window uses a fixed frequency and data rate. The default parameters are 866.7MHz / DR0 (SF12, 125 kHz)​
247 247  
228 +
248 248  == 3.7 KR920-923 (KR920) ==
249 249  
250 -
251 251  * Default channel:
252 252  ** 922.1 - SF7BW125 to SF12BW125
253 253  ** 922.3 - SF7BW125 to SF12BW125
... ... @@ -266,9 +266,9 @@
266 266  ** Uplink channels 1-7(RX1)
267 267  ** 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
268 268  
249 +
269 269  == 3.8 MA869 ==
270 270  
271 -
272 272   Country: Morroco
273 273  
274 274  * Uplink:
... ... @@ -286,15 +286,14 @@
286 286  ** Uplink channels 1-9 (RX1)
287 287  ** 869.525 - SF12BW125 (RX2 downlink only)
288 288  
269 +
289 289  == 3.9 US902-928 (US915) ==
290 290  
291 -
292 292  Used in USA, Canada and South America.
293 293  
294 294  
295 295  === 3.9.1 Before [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]. ===
296 296  
297 -
298 298  Default use CHE=2, Subband 2
299 299  
300 300  * Uplink:
... ... @@ -318,17 +318,21 @@
318 318  ** 927.5 - SF7BW500 to SF12BW500
319 319  ** 923.3 - SF12BW500(RX2 downlink only)
320 320  
300 +
321 321  === 3.9.2 Latest firmware, Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]] ===
322 322  
323 -
324 324  (((
325 325  There is an issue if the end node is fixed at sub-band2. The sensor won't be able to register to other sub-band and can only work for the LoRaWAN server use sub-band2 , such as TTN. To solve this, the user needs to use a USB-TTL adapter to connect to the end node to manually set the sub-band which is very inconvenient.
326 326  )))
327 327  
328 328  (((
329 -So since **Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]**, we have improved this, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join. In this case, the end node can support LoRaWAN servers with different subbands. To make sure the end node will only transmit the proper sub-band after OTAA Joined successfully, the end node will:
308 +
330 330  )))
331 331  
311 +(((
312 +So since **Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]**, we have improved this, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join, In this case, In this case, the end node can support LoRaWAN servers with different subbands. To make sure the end node will only transmit the proper sub-band after OTAA Joined successfully, the end node will:
313 +)))
314 +
332 332  * (((
333 333  Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that subband
334 334  )))
... ... @@ -335,40 +335,10 @@
335 335  * (((
336 336  Use the Join successful sub-band if the server doesn't include subband info in the OTAA Join Accept message ( TTN v2 doesn't include)
337 337  
338 -
339 339  
340 340  )))
341 341  
342 342  = 4. Frequency Bands for different server =
343 343  
344 -
345 345  * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]]
346 346  * Loriot [[https:~~/~~/docs.loriot.io/display/LNS/Regional+Frequency+Plans>>url:https://docs.loriot.io/display/LNS/Regional+Frequency+Plans]]
347 -
348 -= 5. Subband Related questiones in US915, AU915, CN470 bands. =
349 -
350 -
351 -Frequency band US915, AU915 and CN470 supports totally 72 frequency in 8 sub-bands, Normally Gateway only support 8 channels ( one subband). So how does the gateway and end nodes work in such frequency?
352 -
353 -
354 -== 5.1 Set Subband in Gateway. ==
355 -
356 -
357 -* If Gateway choose (% style="color:blue" %)**Semtech UDP packet**(%%) forwarder to Connect to LoRaWAN server. User need to manually set the match Subband in the gateway web UI.
358 -
359 -* If Gateway choose (% style="color:blue" %)**Basic Station Mode**(%%) to connect to the LoRaWAN server. User can set the subband in the Server side and gateway will the correct subband from server. no need to set this in gateway. AWS-IoT, TTN, ChirpStack all supports Basic Station Connection.
360 -
361 -== 5.2 Set Subband in End Node ==
362 -
363 -
364 -* In early End Node firmware, it is pre-set to subband 2 , user need to manually set to proper subband if they don;t use subband 2.
365 -
366 -* In new end node firmware , it supports all sub-bands, and will swtich to the proper subband after OTAA join. So user can use the end node with all sub-band.
367 -
368 -Reference: [[How it affects the OTAA Join when end node is set to support all subbands>>http://wiki.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H13.WhyittakeslongertimeforOTAAjoinedinUS9152FCN4702FAU915band3F]]?
369 -
370 -
371 -
372 -
373 -
374 -
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0