From version < 16.1 >
edited by Edwin Chen
on 2023/12/07 09:47
To version < 11.15 >
edited by Xiaoling
on 2022/06/01 11:48
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -1,5 +1,5 @@
1 1  (% class="wikigeneratedid" id="HEndDeviceFrequencyBand" %)
2 - **Table of** **Contents:**
2 + **Contents:**
3 3  
4 4  {{toc/}}
5 5  
... ... @@ -8,31 +8,33 @@
8 8  
9 9  = 1. Introduction =
10 10  
11 -
12 12  This page list the default frequency band for Dragino End Devices. The frequency bands are base on TTN Frequency Bands. User can modify upgrade firmware to support different frequency band or use AT Command to change the sub band in some frequency bands.
13 13  
14 14  * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]]
15 15  * Frequency Bands vs Country List : Page 11 of [[LoRaWAN Regional Parameters RP2-1.0.3>>url:https://resources.lora-alliance.org/technical-specifications/rp2-1-0-3-lorawan-regional-parameters]]
16 16  
17 -= 2. OTAA Join Behaviour =
18 18  
19 19  
20 -Since 005 LoRaWAN stack: to save battery, once boot, device will first make 200 tries for OTAA Join, the time period of two Join Requests will depends on the DR and the airtime requirement. After this 200 Join finish, device will send a join request every 20 minutes. If device reboot, it will do above loop again.
18 += 2. OTAA Join Behaviour =
21 21  
20 +For 005 LoRaWAN stack: to save battery, once boot, device will make first make 200 tries for OTAA Join, the time period of two Join Requests will depends on the DR and the airtime requirement. After this 200 Join finish, device will send a join request every 20 minutes. If device reboot, it will do above loop again.
21 +
22 22  (((
23 -Since 005 LoRaWAN Stack:
23 +For 005 LoRaWAN Stack:
24 24  )))
25 25  
26 26  * EU868 OTAA Join DR select. SF7->SF8->SF9->SF10->SF11->SF12; Each 3 attempts and then loop
27 -* US915 and AU915 OTAA Join procedure,. End node by default will use all 72 channels (All sub-bands) to join and it will be set to use the proper sub-band after Join success
27 +* US915 and AU915 OTAA Join procedure,. End node by default will use all 72 channels to join and it will be set to use the proper sub-band after Join success
28 28  
29 +
30 +
29 29  = 3. Default Frequency Bands =
30 30  
33 +
31 31  == 3.1 AS923 ==
32 32  
33 33  === 3.1.1 Notice for AS923 Frequency Bands ===
34 34  
35 -
36 36  (((
37 37  Since [[RP002-1.0.1LoRaWAN Regional Parameters>>url:https://lora-alliance.org/sites/default/files/2020-02/rp_2-1.0.1.pdf]], AS923 include three different default settings for different countries: AS923-1, AS923-2 and AS923-3.
38 38  )))
... ... @@ -44,8 +44,6 @@
44 44  
45 45  === 3.1.2 AS920-923 & AS923-925 : AS923-1 (AS923) ===
46 46  
47 -
48 -* **Countries**: Malaysia,
49 49  * Default Uplink channel:
50 50  ** 923.2 - SF7BW125 to SF10BW125
51 51  ** 923.4 - SF7BW125 to SF10BW125
... ... @@ -71,9 +71,10 @@
71 71  ** Uplink channels 1-8 (RX1)
72 72  ** 923.2 - SF10BW125 (RX2)
73 73  
74 -=== 3.1.3 AS923-2 ===
75 75  
76 76  
76 +=== 3.1.3 AS923-2 ===
77 +
77 77  * Default Uplink channel:
78 78  ** 921.4 - SF7BW125 to SF10BW125
79 79  ** 921.6 - SF7BW125 to SF10BW125
... ... @@ -84,9 +84,10 @@
84 84  ** Uplink channels 1-8 (RX1)
85 85  ** 921.4 - SF10BW125 (RX2)
86 86  
87 -=== 3.1.4 AS923-3 ===
88 88  
89 89  
90 +=== 3.1.4 AS923-3 ===
91 +
90 90  * Default Uplink channel:
91 91  ** 916.6 - SF7BW125 to SF10BW125
92 92  ** 916.8 - SF7BW125 to SF10BW125
... ... @@ -97,9 +97,10 @@
97 97  ** Uplink channels 1-8 (RX1)
98 98  ** 916.6 - SF10BW125 (RX2)
99 99  
100 -=== 3.1.5 AS923-4 ===
101 101  
102 102  
104 +=== 3.1.5 AS923-4 ===
105 +
103 103  * Countries : Israel
104 104  * Default Uplink channel:
105 105  ** 917.3 - SF7BW125 to SF10BW125
... ... @@ -110,9 +110,10 @@
110 110  ** Uplink channels 1-8 (RX1)
111 111  ** 917.3 - SF10BW125 (RX2)
112 112  
113 -== 3.2 AU915-928(AU915) ==
114 114  
115 115  
118 +== 3.2 AU915-928(AU915) ==
119 +
116 116  **Before [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]** , Default use CHE=2
117 117  
118 118  * Uplink:
... ... @@ -154,15 +154,13 @@
154 154  Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
155 155  )))
156 156  * (((
157 -Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
161 +Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
158 158  
159 -
160 160  
161 161  )))
162 162  
163 163  == 3.3 CN470-510 (CN470) ==
164 164  
165 -
166 166  Used in China, Default use CHE=1
167 167  
168 168  * Uplink:
... ... @@ -186,9 +186,10 @@
186 186  ** 508.1 - SF7BW125 to SF12BW125
187 187  ** 505.3 - SF12BW125 (RX2 downlink only)
188 188  
189 -== 3.4 EU863-870 (EU868) ==
190 190  
191 191  
193 +== 3.4 EU863-870 (EU868) ==
194 +
192 192  * Uplink:
193 193  ** 868.1 - SF7BW125 to SF12BW125
194 194  ** 868.3 - SF7BW125 to SF12BW125 and SF7BW250
... ... @@ -209,7 +209,6 @@
209 209  
210 210  == 3.5 IN865-867 (IN865) ==
211 211  
212 -
213 213  * Uplink:
214 214  ** 865.0625 - SF7BW125 to SF12BW125
215 215  ** 865.4025 - SF7BW125 to SF12BW125
... ... @@ -219,20 +219,10 @@
219 219  ** Uplink channels 1-3 (RX1)
220 220  ** 866.550 - SF10BW125 (RX2)
221 221  
222 -Gateway has below eight channels in IN865 bands.
223 223  
224 -* 865.0625 - SF7BW125 to SF12BW125
225 -* 865.4025 - SF7BW125 to SF12BW125
226 -* 865.6025 - SF7BW125 to SF12BW125
227 -* 865.9850 - SF7BW125 to SF12BW125
228 -* 866.1850 - SF7BW125 to SF12BW125
229 -* 866.3850 - SF7BW125 to SF12BW125
230 -* 866.5850 - SF7BW125 to SF12BW125
231 -* 866.7850 - SF7BW125 to SF12BW125
232 232  
233 233  == 3.6 KZ865 ==
234 234  
235 -
236 236  * Uplink ~-~- 125Khz , DR0 - DR5
237 237  ** 865.1
238 238  ** 865.2
... ... @@ -244,9 +244,10 @@
244 244  ** The RX1 receive window uses the same channel as the preceding uplink.
245 245  ** The RX2 receive window uses a fixed frequency and data rate. The default parameters are 866.7MHz / DR0 (SF12, 125 kHz)​
246 246  
247 -== 3.7 KR920-923 (KR920) ==
248 248  
249 249  
241 +== 3.7 KR920-923 (KR920) ==
242 +
250 250  * Default channel:
251 251  ** 922.1 - SF7BW125 to SF12BW125
252 252  ** 922.3 - SF7BW125 to SF12BW125
... ... @@ -265,9 +265,10 @@
265 265  ** Uplink channels 1-7(RX1)
266 266  ** 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
267 267  
268 -== 3.8 MA869 ==
269 269  
270 270  
263 +== 3.8 MA869 ==
264 +
271 271   Country: Morroco
272 272  
273 273  * Uplink:
... ... @@ -285,15 +285,15 @@
285 285  ** Uplink channels 1-9 (RX1)
286 286  ** 869.525 - SF12BW125 (RX2 downlink only)
287 287  
288 -== 3.9 US902-928 (US915) ==
289 289  
290 290  
284 +== 3.9 US902-928 (US915) ==
285 +
291 291  Used in USA, Canada and South America.
292 292  
293 293  
294 294  === 3.9.1 Before [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]. ===
295 295  
296 -
297 297  Default use CHE=2, Subband 2
298 298  
299 299  * Uplink:
... ... @@ -319,15 +319,18 @@
319 319  
320 320  === 3.9.2 Latest firmware, Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]] ===
321 321  
322 -
323 323  (((
324 324  There is an issue if the end node is fixed at sub-band2. The sensor won't be able to register to other sub-band and can only work for the LoRaWAN server use sub-band2 , such as TTN. To solve this, the user needs to use a USB-TTL adapter to connect to the end node to manually set the sub-band which is very inconvenient.
325 325  )))
326 326  
327 327  (((
328 -So since **Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]**, we have improved this, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join. In this case, the end node can support LoRaWAN servers with different subbands. To make sure the end node will only transmit the proper sub-band after OTAA Joined successfully, the end node will:
321 +
329 329  )))
330 330  
324 +(((
325 +So since **Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]**, we have improved this, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join, In this case, In this case, the end node can support LoRaWAN servers with different subbands. To make sure the end node will only transmit the proper sub-band after OTAA Joined successfully, the end node will:
326 +)))
327 +
331 331  * (((
332 332  Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that subband
333 333  )))
... ... @@ -334,40 +334,10 @@
334 334  * (((
335 335  Use the Join successful sub-band if the server doesn't include subband info in the OTAA Join Accept message ( TTN v2 doesn't include)
336 336  
337 -
338 338  
339 339  )))
340 340  
341 341  = 4. Frequency Bands for different server =
342 342  
343 -
344 344  * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]]
345 345  * Loriot [[https:~~/~~/docs.loriot.io/display/LNS/Regional+Frequency+Plans>>url:https://docs.loriot.io/display/LNS/Regional+Frequency+Plans]]
346 -
347 -= 5. Subband Related questiones in US915, AU915, CN470 bands. =
348 -
349 -
350 -Frequency band US915, AU915 and CN470 supports totally 72 frequency in 8 sub-bands, Normally Gateway only support 8 channels ( one subband). So how does the gateway and end nodes work in such frequency?
351 -
352 -
353 -== 5.1 Set Subband in Gateway. ==
354 -
355 -
356 -* If Gateway choose (% style="color:blue" %)**Semtech UDP packet**(%%) forwarder to Connect to LoRaWAN server. User need to manually set the match Subband in the gateway web UI.
357 -
358 -* If Gateway choose (% style="color:blue" %)**Basic Station Mode**(%%) to connect to the LoRaWAN server. User can set the subband in the Server side and gateway will the correct subband from server. no need to set this in gateway. AWS-IoT, TTN, ChirpStack all supports Basic Station Connection.
359 -
360 -== 5.2 Set Subband in End Node ==
361 -
362 -
363 -* In early End Node firmware, it is pre-set to subband 2 , user need to manually set to proper subband if they don;t use subband 2.
364 -
365 -* In new end node firmware , it supports all sub-bands, and will swtich to the proper subband after OTAA join. So user can use the end node with all sub-band.
366 -
367 -Reference: [[How it affects the OTAA Join when end node is set to support all subbands>>http://wiki.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H13.WhyittakeslongertimeforOTAAjoinedinUS9152FCN4702FAU915band3F]]?
368 -
369 -
370 -
371 -
372 -
373 -
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0