From version < 13.2 >
edited by Xiaoling
on 2022/12/14 09:21
To version < 14.1 >
edited by Edwin Chen
on 2023/02/02 14:22
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -160,7 +160,7 @@
160 160  Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band
161 161  )))
162 162  * (((
163 -Use the Join successful sub-band if the server doesnt include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
163 +Use the Join successful sub-band if the server doesn't include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include)
164 164  
165 165  
166 166  
... ... @@ -359,3 +359,26 @@
359 359  
360 360  * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]]
361 361  * Loriot [[https:~~/~~/docs.loriot.io/display/LNS/Regional+Frequency+Plans>>url:https://docs.loriot.io/display/LNS/Regional+Frequency+Plans]]
362 +
363 +
364 += 5. Subband Related questiones in US915, AU915, CN470 bands. =
365 +
366 +Frequency band US915, AU915 and CN470 supports totally 72 frequency in 8 sub-bands, Normally Gateway only support 8 channels ( one subband). So how does the gateway and end nodes work in such frequency?
367 +
368 +== 5.1 Set Subband in Gateway. ==
369 +
370 +* If Gateway choose **Semtech UDP packet** forwarder to Connect to LoRaWAN server. User need to manually set the match Subband in the gateway web UI.
371 +* If Gateway choose **Basic Station Mode** to connect to the LoRaWAN server. User can set the subband in the Server side and gateway will the correct subband from server. no need to set this in gateway. AWS-IoT, TTN, ChirpStack all supports Basic Station Connection.
372 +
373 +== 5.2 Set Subband in End Node ==
374 +
375 +* In early End Node firmware, it is pre-set to subband 2 , user need to manually set to proper subband if they don;t use subband 2.
376 +* In new end node firmware , it supports all sub-bands, and will swtich to the proper subband after OTAA join. So user can use the end node with all sub-band.
377 +
378 +Reference: [[How it affects the OTAA Join when end node is set to support all subbands>>http://wiki.dragino.com/xwiki/bin/view/Main/LoRaWAN%20Communication%20Debug/#H13.WhyittakeslongertimeforOTAAjoinedinUS9152FCN4702FAU915band3F]]?
379 +
380 +
381 +
382 +
383 +
384 +
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0