Changes for page End Device Frequency Band
Last modified by Edwin Chen on 2024/10/21 20:35
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -16,6 +16,7 @@ 16 16 17 17 18 18 19 + 19 19 = 2. OTAA Join Behaviour = 20 20 21 21 ... ... @@ -30,6 +30,7 @@ 30 30 31 31 32 32 34 + 33 33 = 3. Default Frequency Bands = 34 34 35 35 ... ... @@ -80,6 +80,7 @@ 80 80 81 81 82 82 85 + 83 83 === 3.1.3 AS923-2 === 84 84 85 85 ... ... @@ -95,6 +95,7 @@ 95 95 96 96 97 97 101 + 98 98 === 3.1.4 AS923-3 === 99 99 100 100 ... ... @@ -110,6 +110,7 @@ 110 110 111 111 112 112 117 + 113 113 === 3.1.5 AS923-4 === 114 114 115 115 ... ... @@ -125,6 +125,7 @@ 125 125 126 126 127 127 133 + 128 128 == 3.2 AU915-928(AU915) == 129 129 130 130 ... ... @@ -151,6 +151,7 @@ 151 151 ** 927.5 - SF7BW500 to SF12BW500 152 152 ** 923.3 - SF12BW500(RX2 downlink only) 153 153 160 + 154 154 ((( 155 155 There is a issue if the end node is fixed at sub-band2. The sensor won't be able to register to other sub-band and can only works for the LoRaWAN server use sub-band2 , such as TTN. To solve this, user need to use a USB-TTL adapter to connect to the end node to manually set the sub-band which is very inconvinient. 156 156 ))) ... ... @@ -204,6 +204,7 @@ 204 204 205 205 206 206 214 + 207 207 == 3.4 EU863-870 (EU868) == 208 208 209 209 ... ... @@ -239,18 +239,8 @@ 239 239 ** 866.550 - SF10BW125 (RX2) 240 240 241 241 242 -Gateway has below eight channels in IN865 bands. 243 243 244 -* 865.0625 - SF7BW125 to SF12BW125 245 -* 865.4025 - SF7BW125 to SF12BW125 246 -* 865.6025 - SF7BW125 to SF12BW125 247 -* 865.9850 - SF7BW125 to SF12BW125 248 -* 866.1850 - SF7BW125 to SF12BW125 249 -* 866.3850 - SF7BW125 to SF12BW125 250 -* 866.5850 - SF7BW125 to SF12BW125 251 -* 866.7850 - SF7BW125 to SF12BW125 252 252 253 - 254 254 == 3.6 KZ865 == 255 255 256 256 ... ... @@ -267,6 +267,7 @@ 267 267 268 268 269 269 268 + 270 270 == 3.7 KR920-923 (KR920) == 271 271 272 272 ... ... @@ -290,6 +290,7 @@ 290 290 291 291 292 292 292 + 293 293 == 3.8 MA869 == 294 294 295 295 ... ... @@ -312,6 +312,7 @@ 312 312 313 313 314 314 315 + 315 315 == 3.9 US902-928 (US915) == 316 316 317 317 ... ... @@ -347,9 +347,9 @@ 347 347 348 348 349 349 351 + 350 350 === 3.9.2 Latest firmware, Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]] === 351 351 352 - 353 353 ((( 354 354 There is an issue if the end node is fixed at sub-band2. The sensor won't be able to register to other sub-band and can only work for the LoRaWAN server use sub-band2 , such as TTN. To solve this, the user needs to use a USB-TTL adapter to connect to the end node to manually set the sub-band which is very inconvenient. 355 355 ))) ... ... @@ -375,6 +375,5 @@ 375 375 376 376 = 4. Frequency Bands for different server = 377 377 378 - 379 379 * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]] 380 380 * Loriot [[https:~~/~~/docs.loriot.io/display/LNS/Regional+Frequency+Plans>>url:https://docs.loriot.io/display/LNS/Regional+Frequency+Plans]]