Changes for page End Device Frequency Band
Last modified by Edwin Chen on 2024/10/21 20:35
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -16,7 +16,6 @@ 16 16 17 17 18 18 19 - 20 20 = 2. OTAA Join Behaviour = 21 21 22 22 ... ... @@ -31,7 +31,6 @@ 31 31 32 32 33 33 34 - 35 35 = 3. Default Frequency Bands = 36 36 37 37 ... ... @@ -82,7 +82,6 @@ 82 82 83 83 84 84 85 - 86 86 === 3.1.3 AS923-2 === 87 87 88 88 ... ... @@ -98,7 +98,6 @@ 98 98 99 99 100 100 101 - 102 102 === 3.1.4 AS923-3 === 103 103 104 104 ... ... @@ -114,7 +114,6 @@ 114 114 115 115 116 116 117 - 118 118 === 3.1.5 AS923-4 === 119 119 120 120 ... ... @@ -130,7 +130,6 @@ 130 130 131 131 132 132 133 - 134 134 == 3.2 AU915-928(AU915) == 135 135 136 136 ... ... @@ -157,7 +157,6 @@ 157 157 ** 927.5 - SF7BW500 to SF12BW500 158 158 ** 923.3 - SF12BW500(RX2 downlink only) 159 159 160 - 161 161 ((( 162 162 There is a issue if the end node is fixed at sub-band2. The sensor won't be able to register to other sub-band and can only works for the LoRaWAN server use sub-band2 , such as TTN. To solve this, user need to use a USB-TTL adapter to connect to the end node to manually set the sub-band which is very inconvinient. 163 163 ))) ... ... @@ -211,7 +211,6 @@ 211 211 212 212 213 213 214 - 215 215 == 3.4 EU863-870 (EU868) == 216 216 217 217 ... ... @@ -247,8 +247,18 @@ 247 247 ** 866.550 - SF10BW125 (RX2) 248 248 249 249 242 +Gateway has below eight channels in IN865 bands. 250 250 244 +* 865.0625 - SF7BW125 to SF12BW125 245 +* 865.4025 - SF7BW125 to SF12BW125 246 +* 865.6025 - SF7BW125 to SF12BW125 247 +* 865.9850 - SF7BW125 to SF12BW125 248 +* 866.1850 - SF7BW125 to SF12BW125 249 +* 866.3850 - SF7BW125 to SF12BW125 250 +* 866.5850 - SF7BW125 to SF12BW125 251 +* 866.7850 - SF7BW125 to SF12BW125 251 251 253 + 252 252 == 3.6 KZ865 == 253 253 254 254 ... ... @@ -265,7 +265,6 @@ 265 265 266 266 267 267 268 - 269 269 == 3.7 KR920-923 (KR920) == 270 270 271 271 ... ... @@ -289,7 +289,6 @@ 289 289 290 290 291 291 292 - 293 293 == 3.8 MA869 == 294 294 295 295 ... ... @@ -312,7 +312,6 @@ 312 312 313 313 314 314 315 - 316 316 == 3.9 US902-928 (US915) == 317 317 318 318 ... ... @@ -348,9 +348,9 @@ 348 348 349 349 350 350 351 - 352 352 === 3.9.2 Latest firmware, Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]] === 353 353 352 + 354 354 ((( 355 355 There is an issue if the end node is fixed at sub-band2. The sensor won't be able to register to other sub-band and can only work for the LoRaWAN server use sub-band2 , such as TTN. To solve this, the user needs to use a USB-TTL adapter to connect to the end node to manually set the sub-band which is very inconvenient. 356 356 ))) ... ... @@ -369,10 +369,13 @@ 369 369 * ((( 370 370 Use the Join successful sub-band if the server doesn't include subband info in the OTAA Join Accept message ( TTN v2 doesn't include) 371 371 371 + 372 + 372 372 373 373 ))) 374 374 375 375 = 4. Frequency Bands for different server = 376 376 378 + 377 377 * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]] 378 378 * Loriot [[https:~~/~~/docs.loriot.io/display/LNS/Regional+Frequency+Plans>>url:https://docs.loriot.io/display/LNS/Regional+Frequency+Plans]]