Changes for page End Device Frequency Band
Last modified by Edwin Chen on 2024/10/21 20:35
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -1,11 +1,16 @@ 1 1 (% class="wikigeneratedid" id="HEndDeviceFrequencyBand" %) 2 - **Contents:**2 + 3 3 4 - {{toc/}}4 += Contents ~[[[hide>>http://8.211.40.43:8080/xwiki/bin/view/Main/End%20Device%20Frequency%20Band]]] = 5 5 6 +== Contents == 6 6 8 + ~[[[hide>>url:https://wiki.dragino.com/index.php/End_Device_Frequency_Band#]]] 7 7 10 +* [[1 Introduction>>url:https://wiki.dragino.com/index.php/End_Device_Frequency_Band#Introduction]] 8 8 12 +{{toc/}} 13 + 9 9 = 1. Introduction = 10 10 11 11 This page list the default frequency band for Dragino End Devices. The frequency bands are base on TTN Frequency Bands. User can modify upgrade firmware to support different frequency band or use AT Command to change the sub band in some frequency bands. ... ... @@ -13,19 +13,15 @@ 13 13 * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]] 14 14 * Frequency Bands vs Country List : Page 11 of [[LoRaWAN Regional Parameters RP2-1.0.3>>url:https://resources.lora-alliance.org/technical-specifications/rp2-1-0-3-lorawan-regional-parameters]] 15 15 16 - 17 17 = 2. OTAA Join Behaviour = 18 18 19 19 For 005 LoRaWAN stack: to save battery, once boot, device will make first make 200 tries for OTAA Join, the time period of two Join Requests will depends on the DR and the airtime requirement. After this 200 Join finish, device will send a join request every 20 minutes. If device reboot, it will do above loop again. 20 20 21 -((( 22 22 For 005 LoRaWAN Stack: 23 -))) 24 24 25 25 * EU868 OTAA Join DR select. SF7->SF8->SF9->SF10->SF11->SF12; Each 3 attempts and then loop 26 26 * US915 and AU915 OTAA Join procedure,. End node by default will use all 72 channels to join and it will be set to use the proper sub-band after Join success 27 27 28 - 29 29 = 3. Default Frequency Bands = 30 30 31 31 ... ... @@ -33,18 +33,14 @@ 33 33 34 34 === 3.1.1 Notice for AS923 Frequency Bands === 35 35 36 -((( 37 37 Since [[RP002-1.0.1LoRaWAN Regional Parameters>>url:https://lora-alliance.org/sites/default/files/2020-02/rp_2-1.0.1.pdf]], AS923 include three different default settings for different countries: AS923-1, AS923-2 and AS923-3. 38 -))) 39 39 40 -((( 41 41 AS923-1 use the same default uplink frequency as previous AS923 firmware. AS923-2 and AS923-3 are new with different default uplink frequency. User need to know exactly the frequency bands from the LoRaWAN server and choose the right firmware version for the end node. 42 -))) 43 43 44 44 42 + 45 45 === 3.1.2 AS920-923 & AS923-925 : AS923-1 (AS923) === 46 46 47 -* **Countries**: Malaysia, 48 48 * Default Uplink channel: 49 49 ** 923.2 - SF7BW125 to SF10BW125 50 50 ** 923.4 - SF7BW125 to SF10BW125 ... ... @@ -70,7 +70,6 @@ 70 70 ** Uplink channels 1-8 (RX1) 71 71 ** 923.2 - SF10BW125 (RX2) 72 72 73 - 74 74 === 3.1.3 AS923-2 === 75 75 76 76 * Default Uplink channel: ... ... @@ -83,7 +83,6 @@ 83 83 ** Uplink channels 1-8 (RX1) 84 84 ** 921.4 - SF10BW125 (RX2) 85 85 86 - 87 87 === 3.1.4 AS923-3 === 88 88 89 89 * Default Uplink channel: ... ... @@ -96,7 +96,6 @@ 96 96 ** Uplink channels 1-8 (RX1) 97 97 ** 916.6 - SF10BW125 (RX2) 98 98 99 - 100 100 === 3.1.5 AS923-4 === 101 101 102 102 * Countries : Israel ... ... @@ -109,7 +109,6 @@ 109 109 ** Uplink channels 1-8 (RX1) 110 110 ** 917.3 - SF10BW125 (RX2) 111 111 112 - 113 113 == 3.2 AU915-928(AU915) == 114 114 115 115 **Before [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]** , Default use CHE=2 ... ... @@ -135,29 +135,15 @@ 135 135 ** 927.5 - SF7BW500 to SF12BW500 136 136 ** 923.3 - SF12BW500(RX2 downlink only) 137 137 138 -((( 139 139 There is a issue if the end node is fixed at sub-band2. The sensor won't be able to register to other sub-band and can only works for the LoRaWAN server use sub-band2 , such as TTN. To solve this, user need to use a USB-TTL adapter to connect to the end node to manually set the sub-band which is very inconvinient. 140 -))) 141 141 142 - 143 -((( 144 144 So since **Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]**, To make sure the end node supports all sub band by default. In the OTAA Join process, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join. 145 -))) 146 146 147 - 148 -((( 149 149 After Join success, the end node will switch to the correct sub band by: 150 -))) 151 151 152 -* ((( 153 -Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 154 -))) 155 -* ((( 156 -Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 137 +* Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that sub-band 138 +* Use the Join successful sub-band if the server doesn’t include sub-band info in the OTAA Join Accept message ( TTN v2 doesn't include) 157 157 158 - 159 -))) 160 - 161 161 == 3.3 CN470-510 (CN470) == 162 162 163 163 Used in China, Default use CHE=1 ... ... @@ -183,7 +183,6 @@ 183 183 ** 508.1 - SF7BW125 to SF12BW125 184 184 ** 505.3 - SF12BW125 (RX2 downlink only) 185 185 186 - 187 187 == 3.4 EU863-870 (EU868) == 188 188 189 189 * Uplink: ... ... @@ -215,7 +215,6 @@ 215 215 ** Uplink channels 1-3 (RX1) 216 216 ** 866.550 - SF10BW125 (RX2) 217 217 218 - 219 219 == 3.6 KZ865 == 220 220 221 221 * Uplink ~-~- 125Khz , DR0 - DR5 ... ... @@ -229,7 +229,6 @@ 229 229 ** The RX1 receive window uses the same channel as the preceding uplink. 230 230 ** The RX2 receive window uses a fixed frequency and data rate. The default parameters are 866.7MHz / DR0 (SF12, 125 kHz) 231 231 232 - 233 233 == 3.7 KR920-923 (KR920) == 234 234 235 235 * Default channel: ... ... @@ -250,11 +250,8 @@ 250 250 ** Uplink channels 1-7(RX1) 251 251 ** 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125) 252 252 253 - 254 254 == 3.8 MA869 == 255 255 256 - Country: Morroco 257 - 258 258 * Uplink: 259 259 ** 869.1 - SF7BW125 to SF12BW125 260 260 ** 869.3 - SF7BW125 to SF12BW125 ... ... @@ -270,12 +270,10 @@ 270 270 ** Uplink channels 1-9 (RX1) 271 271 ** 869.525 - SF12BW125 (RX2 downlink only) 272 272 273 - 274 274 == 3.9 US902-928 (US915) == 275 275 276 276 Used in USA, Canada and South America. 277 277 278 - 279 279 === 3.9.1 Before [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]. === 280 280 281 281 Default use CHE=2, Subband 2 ... ... @@ -301,30 +301,15 @@ 301 301 ** 927.5 - SF7BW500 to SF12BW500 302 302 ** 923.3 - SF12BW500(RX2 downlink only) 303 303 304 - 305 305 === 3.9.2 Latest firmware, Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]] === 306 306 307 -((( 308 308 There is an issue if the end node is fixed at sub-band2. The sensor won't be able to register to other sub-band and can only work for the LoRaWAN server use sub-band2 , such as TTN. To solve this, the user needs to use a USB-TTL adapter to connect to the end node to manually set the sub-band which is very inconvenient. 309 -))) 310 310 311 -((( 312 - 313 -))) 314 - 315 -((( 316 316 So since **Since [[Dragino DLS-005 LoRaWAN Stack>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/DR-LWS/changelog]]**, we have improved this, the end node will use frequency 1 from sub-band1, then frequency 1 from sub-band2, then frequency 1 from sub-band3, etc to process the OTAA join, In this case, In this case, the end node can support LoRaWAN servers with different subbands. To make sure the end node will only transmit the proper sub-band after OTAA Joined successfully, the end node will: 317 -))) 318 318 319 -* ((( 320 -Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that subband 321 -))) 322 -* ((( 323 -Use the Join successful sub-band if the server doesn't include subband info in the OTAA Join Accept message ( TTN v2 doesn't include) 281 +* Check what sub-band the LoRaWAN server ask from the OTAA Join Accept message and switch to that subband 282 +* Use the Join successful sub-band if the server doesn't include subband info in the OTAA Join Accept message ( TTN v2 doesn't include) 324 324 325 - 326 -))) 327 - 328 328 = 4. Frequency Bands for different server = 329 329 330 330 * TTN Frequency Band Settings: [[https:~~/~~/www.thethingsnetwork.org/docs/lorawan/frequency-plans.html>>url:https://www.thethingsnetwork.org/docs/lorawan/frequency-plans.html]]